RDC6 Series AC Contactor is designed for circuits with AC50/60Hz, supporting a rated operating voltage up to 660V and a current up to 95A. It is used for remote connection and disconnection of circuits and can be combined with RDR6 series thermal relays to form an electromagnetic starter for overload protection. The contactor can be equipped with auxiliary contact groups, air delay contacts, and mechanical interlock mechanisms to form various configurations like delay contactors and star delta starters. It complies with standards GB14048.4 and IEC60947-4-1.

Model Implications
The model numbers indicate the contactor's specifications, such as contact configuration and rated current. For example, '10' indicates a contactor with 3P+NO contacts for currents 32A and below, while '11' indicates 3P+NO+NC contacts for currents 40A and above.

Operating and Installation Conditions
- Ambient temperature: -5°C to +40°C, with a 24-hour average not exceeding +35°C.
- Installation altitude: Up to 2000m.
- Humidity: 50% at +40°C, up to 90% at 20°C with precautions for condensation.
- Pollution grade: 3
- Installation: Should be in locations without significant impact or vibration, with a gradient not exceeding ±5°.
- Installation category: III

Main Technical Parameters
Technical parameters are detailed in tables, specifying rated insulation voltage, thermal current settings, and operating currents for various voltages and configurations. For example, the RDC6-09 model has a rated insulation voltage of 690V and a setting thermal current of 20A.

Auxiliary Contacts and Air Delay Parameters
Details are provided for auxiliary contact groups and air delay contacts, including rated insulation voltage, thermal current, and life expectancy in terms of electrical and mechanical operations.

Wiring and Installation
Wiring maps are provided for different RDC6 models, detailing the connections for various configurations. External and installation dimensions are also specified for each model.

Ordering Information
When ordering, specify the product model, coil voltage and frequency, and quantity. For example, RDC6-0910 with a coil voltage of 220V, 50Hz, and a quantity of 10.
See more

Catalog excerpts

RDC6 Series AC Contactor-1

Usage and its scope of application RDC6 Series AC Contactor is suitable for the circuit of AC50/60Hz, rated operating voltage up to 660V, rated operating current up to 95A, for the use of remotely connecting and breaking the circuit, and can be combined with RDR6 series thermal relay into electromagnetic starter to protect the circuit’s over-load that may be produced by operation. Contactor can also be attached with building block type auxiliary contact group, air delay contact, mechanical interlock mechanism, etc. accessories, to be composed into delay contactor, directional contactor, star delta starter. This product confirms to: GB14048.4, IEC60947-4-1 etc. standards. 10 indicates: contactor that is 32A and below, its contact is 3P+NO; 01 indicates: contactor that is 32A and below, its contact is 3P+NC; 11 indicates: contactor that is 40A and above, its contact is 3P+NO+NC; 04 indicates: contactor that is 25A and below, its main contacts are 4NO; 08 indicates: contactor that is 25A and below, its main contacts are 2P+2R P is the main normal open contact, and R is the main normal close contact (NO-normal open auxiliary contact, NC- normal close auxiliary contact) Rated operating current Design serial No. AC Contactor Enterprise code Normal operating condition and installation condition 3.1 Ambient temperature: -5C~+40C; Average value in 24h does not exceed +35C 3.2 Altitude height of Installation places does not exceed 2000m. 3.3 Condition of atmosphere When it is the highest temperature +40C, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20C, and it should take special measurements when there occurred condensation due to the temperature variation. 3.4 Pollution grade: 3 3.5 Installation condition: Installing at the places that without obvious impact and vibration. 3.6 Installation position: Gradient between the installation side and the vertical side does not exceed ±5°. 3.7 Installation category: III grade Main technique parameter 4.1 Main technique parameter of contactor to see table 1 4.2 Main technique parameter for the coil of contactor to see table 1 4.3 Technique parameter for the F4 (LA1-D) series auxiliary contacts group and LA2-D, LA3-D series air delay contact to see table 2 and table 4

 Open the catalog to page 1
RDC6 Series AC Contactor-2

Rated insulation voltage V Setting thermal current (£40"C) A Rated operating current AC-3 380V three-phase squirrel cage type motor kW 440V Main Contacts AC-1(£40C) A Max. current when connecting A Max. current when breaking A Electrical life Operation frequency Mechanical life times/h Electrical life Mechanical life ten thousand times/h Pcs Flexible wire with cold-press Wiring terminal mm Terminal Flexible wire without cold-press terminal mm2 Single hard wire mm2

 Open the catalog to page 2
RDC6 Series AC Contactor-3

Technique parameter of F4 (LA1-D) series auxiliary contact group Model F4-11 F4-20 F4-02 F4-22 F4-40 F4-04 F4-31 F4-13 Combined couple Rated insulation Setting thermal Electrical life Mechanical life Highest operation The connectable of contact voltage V current A (million times) (million times) frequency times/s min. load Table 2 The conductive wire connected on the terminal 1~2 pcs flexible wire or hard wire, its cross section is 1.5mm -2.5mm2 Technique parameter of LA2-D, LA3-D series Air delay Table 3 Rated Setting Chara.Scope Model insulation thermal of of voltage V current A...

 Open the catalog to page 3
RDC6 Series AC Contactor-4

Contactor ► RDC6 Series AC Contactor► External and installation dimension A1/A2 Map 10 External dimension for RDC6-40, 50, 65 Map 11 External dimension for RDC6-80, 95 ► Ordering Notice It required to be noted: product model, rated operating voltage and frequency of coil, and the required quantity, if require standard DIN rail, please note additionally. For example: RDC6-0910, Coil voltage: 220V, 50Hz, 10 pcs

 Open the catalog to page 4

All PEOPLE ELE. APPLIANCE GROUP CO., LTD. catalogs and technical brochures

  1. DZ47-63

    2  Pages

  2. LXP1

    2  Pages

  3. RDQ1

    6  Pages

  4. RDX30LE-32

    2  Pages

  5. RDX6LE-40

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.