RDB67LE-63 series RCBO
3Pages

{{requestButtons}}

Catalog excerpts

RDB67LE-63 series RCBO - 1

1. Application RDB67LE series residual current action circuit breaker is applied to the circuit of AC50Hz, rated voltage up to 380V,rated current up to 63A,for circuit unfrequently making,breaking and transferring. This product has protect functions against residual current (electrical shock),overload,short-circuit. And it also has advantages of high-breaking capacity,compact volume,light weight,Generic component,well-looking. This product conforms to standard of IEC61009-1:2012. 2. Normal operate and install condition 2.1 Ambient temperature: from -5°Cto +40°C,and average temperature shall not exceed +35 °C 2.2 Altitude: no more than 2000m 2.3 Humidity:Max up to 50% at +40°C.But the higher humidity is acceptable at lower temperature,for instance, 90% is acceptable at +20°C.And the condensation shall be taken care. 2.5 External magnetic of Install location should not 5 time of exceed earth magnetic at any direction. 2.6 The Standard mounting rail(TH35 type) is adopted at distribute box,cabinets or boxes. 2.7 Vertical install is adopted generally,install plate and vertical plate tilt shall no more than 5°. And the handle upward is connecting position. 2.8 Install location shall have no obvious impact and vibrate, no explosive medium,and no influence of weather. 2.9 Install type:ll,lll type.

Open the catalog to page 1
RDB67LE-63 series RCBO - 2

3. Model No. 4. Specification and technical parameter 4.1 Tablel -r i_ I a Pole Tablel 5 Structure and operate principle 5.1 This product is current operate type electronic residual current circuit breaker,consists of RDB67-63H series circuit breaker and residual current component(release). www.chinapeople.com

Open the catalog to page 2
RDB67LE-63 series RCBO - 3

8. Shape and install dimension Figl 6.7 Install method: TH35 type standard Din Rail,Install rail dimension as Fig2. 35±0.30 Figl 7. Operate, Maintains. 7.1 Check before operate a. Please check the connection, In particular check that input terminal (N, 1,3,5) should connect power line, output terminal (N,2,4,6) should connect load line, b. Please check the situations like short-circuit and connect to ground in each terminals or other exposed conduct component. 7.2Before operate,it should operate the test button to ensure the protect characteristic and normal operation according to...

Open the catalog to page 3