Catalog excerpts
Motor starter ► QCX5 series electromagnetic starter^Application QCX5 series electromagnetic starter,is applicable for appliance of AC50Hz, rated voltage up to 660V,rated current up to 40A.It also can telecontrol the motor starting and stop,and protect motor against damage of overload,phase loss and undervoltage. ► Model No. ^Normal working condition and installation condition 3.1 Altitude: lower than 2000m. 3.2 Ambient temperature: no higher than +40oC,and no lower than -5oC, and day average temperature shall no more than +35°C. 3.3 Humidity: Relative humidity shall not excced 50% at the Max temperature 40°C,and higher humidity could be accepted at lower temperature. The condensation must be taken care which is caused by temperature change. 3.4 Angle between installation plane and horizontai plane should not exceed 5o. 3.5 Installation location have no affect of obvious vibration and impact,rain and snow. 3.6 Installation type:III type 3.7Pullotion class:NI type 4.2 rated operational voltage 220V,380V,660V 4.3 rated operational voltage and thermal component rated current and controlled three-phase motor Max power see Tablel. www.peopleelectric.com simon@chinapeople.com
Open the catalog to page 1Motor starter QCX5 series electromagnetic starter 4.4 Overload protection device protection feature 4.4.1 when loading of each phase is balance,motion feature see Table2 table2 NO. Setting current multiples intial time autuation time ambient temperature cold state heating state heating state cold state 4.4.2 when loading of each phase is imbalance,motion feature see Table3 table3 NO. Setting current multiples any two-pahse autuation time tihrd pahse intial time ambient temperature cold state heating state Appearance and mounting dimension mounting boring preparative boring ground protection...
Open the catalog to page 2All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages