RCBO DZ47-32, 63Residual current operated circuit breaker with over-current protection ► Application DZ47LE series residual current operated circuit breaker, is applied to the circuit of AC 50Hz, rated voltage 230V/400V, rated current up to 32A(63A),for protection of the circuit from residual current, over-load and short-circuit,and for the circuit infrequent making, breaking and transfering. This production has the advantages of high breaking capacity, good accessory adaptability, small volume, light weight, beatiful outlook and convenient using. This product conforms to the standard of GB16917.1. dz 47 le-d/dd N: with the unbreaking neutral line Poles Frame size rated current (A) Electronic residual current circuit breaker Design No. Plastic shell circuit breaker 3.1 Temperature: no higher than +40 °C , and no lower than -5 °C, and the average temperture no higher than +35 °C. 3.2 Altitudeof Installation location no more than 2000m. 3.3 The relative humidity: no more than 50%, when Temperature is +40 °C. The product can withstand the higher humidity under lower temperature, for instance, when temperature at +20°C, the product can withstand 90% relative humidity. The condensation that happened because of temperature changes should be taken care in special measurements 3.4 Class of pollution : 2 Class 3.6 The megnetic field of the installation place should not bigger than the earth magnetic field in any direction. 3.7 Installation method: TH35-7.5, distribution box or cabinet. 3.8 Installation: The angle between the vertical plane and installation plane no more than 5. 3.9 Installation condition: the installation location should have no heavy impact and vibration, and in the medium that no danger (explosion). 3.10 Installation type : 2 ,3 Class Main technical parameter 4.1 Speacification and technical parameter, see table 1. 4.2 Rated residual current operated: 30mA. 4.3 Rated residual current unoperated: 15mA 4.4 Rated residual making and breaking capacity: 2000A 4.5 Leakage operating time: 0.1s 4.6 Rated impulse withstand voltage Ui: Uimp=4kV 4.7 Delay operated performance: see Table 2 4.8 Instantaneous operated performance: see Table 3
Open the catalog to page 1RCBO DZ47-32, 63Residual current operated circuit breaker with over-current protection Rated current(A) Rated short-circuit breaking capacity Vo|tage (V) Srhe<arkingccaitpacity (A) Table 2 Tripping type Rated current (A) Testing current (A) Initial state Limit time Excepting result cold state Trippmg Tripping type c D c D Initial state cold state cold state Table 3 Excepting result Nor-tripping Tripping ► Overall and installation dimensions Installation method: TH35-7.5 Din rail www.chinapeople.com Email: simon@chinapeople.com
Open the catalog to page 2All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages