CJX5 Series AC Contactor
3Pages

{{requestButtons}}

Catalog excerpts

CJX5 Series AC Contactor - 1

Contactor CJX5 Series AC Contactor Usage and its scope of application CJX5 Series AC Contactor is suitable for the circuit of AC 50Hz or 60Hz, rated operating voltage up to 690V, rated current up to 105A, for remotely connecting and breaking the electric products, can be combined with the thermal relay into electromagnetic starter, to protect the circuit that may occur operation over load. Product confirms to GB14048.4, IEC60947-4-1 standards. Quantity of auxiliary contacts single digit implies the quantity of NC contacts tens digit implies the quantity of NO contacts Rated current Design serial no. Miniature AC Contactor Normal operating condition and installation condition 3.1 Ambient temperature: -5℃~+40℃, average value within 24h does not exceed +35℃ 3.2 Altitude: does not exceed 2000m 3.3 Relative humidity does not exceed 50% when the highest temperature is +40℃, it is allowed relatively high humidity when it is at relatively low temperature, for example, it reaches 90% when 20℃, it should take appropriate measurements when there produced condensation on the product due to the temperature variation. 3.4 Grade of pollution: 3 3.5 Installation category: III 3.6 Installation position: gradient between installation side and the vertical side does not exceed ±5° 3.7 Impact and vibration: product should be installed at the places of without obvious shake, impact and vibration. Main technique parameter 4.1 Main technique parameter of contactor to see table 1 4.2 Acting characteristics: contactor can reliably pull-in when it is at ambient temperature of -5℃~+40℃, the coil is electrified with any voltage within 85%~110% Us, and it can reliably release with 20%~75% Us. 4.3 Contactor is suitable for 8 hours operation system, intermitted operation system and continuous period operation system. 4.4 Quantity of contacts to see table 2

Open the catalog to page 1
CJX5 Series AC Contactor - 3

External and installation dimension External and installation dimension to see map 1, table 3 6.2 Rated operating voltage and frequency of coil 6.4 if require the standard rail please noted additionally. For example, CJX5-12/10, 380V, 50Hz, 100 pcs. www.peopleelectric.com siinon@cliinapeople.com

Open the catalog to page 3

All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures

  1. DZ47-63

    2 Pages

  2. LXP1

    2 Pages

  3. RDQ1

    6 Pages

  4. RDX30LE-32

    2 Pages

  5. RDX6LE-40

    2 Pages