1.APPLICATION RANGE CJX2 series AC Contactor is mainly used in the circuit of AC 50Hz or 60Hz, rated operating voltage up to 690V, rated operating current up to 630A, for the use of remotely connecting and breaking, it also can be connected with thermal relay combined into electromagnetic starter to protect the circuit’s over-load of operation. Product confirms to: GB14048.4, IEC60947-4-1 etc. standards. 2.Model and its implication CJ X 2 Number of pole (2 or 4, it implies as 3P when does not note) Derived code, it implies as directional contactor if with N (Ns is the horizontal installation, Nc is vertical installation) Rated operating current (when AC-3, 380V) (A) Design serial No. Miniature AC Contactor 3.APPLICATION ENVIRONMENT CONDITION 3.1 Altitude height of Installation places does not exceed 2000m 3.2 Ambient temperature Up limitation of ambient temperature does not exceed +40℃; Average value in 24h of ambient temperature does not exceed +35℃. The low limitation of ambient temperature does not lower than -5℃. 3.3 Condition of atmosphere 3.3.1 Humidity When it is the highest temperature +40℃, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20 ℃ , and it should take special measurements when there occurring condensation due to the temperature variation. 3.3.2 Pollution grade:3 3.4 Installation condition Installing at the places that without impact vibration and without snow or rain; up terminal connects power, and the low terminal connects the load; the gradient between the vertical and the product does not exceed 5° 3.5 Installation category: III

Open the catalog to page 1
CJX2-115~630 Series AC Contactor - 2

Contactor CJX2-115~630 Series AC Contactor 4.1.2 Rated control power voltage of contactor’s coil Us: AC 50Hz, 110, 127, 220, 380, 415, 440V, special voltage can be customized. 4.2 Main technique parameter of contactor 4.2.1 Characteristics of action Pull-in voltage 85%—110% Us Release voltage CJX2-115—265 is 20%—75% Us 4.2.2 Main parameter and technique performance index of contactor to see table 1 Table 1 4.2.3 Model specification and parameter of auxiliary contact group to see table 2 Control capacity www.peopleelectric.com simon@chinapeople.com

Open the catalog to page 2
CJX2-115~630 Series AC Contactor - 3

4.3 Main specification code of coil to see table 3 Table 3 Operating voltage V Coil code 5.External and installation dimension 5.1 External dimension and installation dimension of contactor to see table 4 CJX2-115~330

Open the catalog to page 3
CJX2-115~630 Series AC Contactor - 4

Contactor CJX2-115~630 Series AC Contactor Table 5 mm Note: 1) Assemble and disassemble the coil required minimum distance Arcing distance according to the operating voltage and breaking capacity

Open the catalog to page 4
CJX2-115~630 Series AC Contactor - 5

m Contactor CJX2-115~630 Series AC Contactor 6.Characteristics of structure 6.1 Contactor is mainly comprised of arcing system, contact system, base, and magnetic system (include iron core and coil) to see picture 1 In picture: 1 .Arcing system 2.Contact system 3.Base 4.Magnetic system Picture 1 General structure sketch map for CJX2-115~265 contactor 6.2 Contact system of contactor is direct-acting, double breakpoint arrangement, the lower base adopts the aluminium alloy material, the coil is the plastic sealing structure, and the coil combined with magnetic yoke into a whole, which can be...

Open the catalog to page 5
CJX2-115~630 Series AC Contactor - 6

Contactor CJX2-115~630 Series AC Contactor www.peopleelectric.com simon@chinapeopl