Application Range
The CJX2 series AC Contactor is designed for circuits with AC 50Hz or 60Hz, supporting a rated operating voltage up to 690V and a current up to 95A. It is used for remote connection and disconnection and can be combined with a thermal relay to form an electromagnetic starter for overload protection. The contactor can be equipped with auxiliary contacts, air delay contacts, and mechanical interlock mechanisms to form delay contactors, directional contactors, and star-delta starters. It complies with GB14048.4 and IEC60947-4-1 standards.
Model and Implication
The model CJX2 is followed by numbers indicating specific configurations, such as contact types and rated operating currents. For example, '10' indicates a contactor with 3P+NO contacts for currents 32A and below, while '11' indicates 3P+NO+NC contacts for 40A and above.
Application Environment Condition
The installation altitude should not exceed 2000m. The ambient temperature should not exceed +40℃, with a 24-hour average not exceeding +35℃, and should not be lower than -5℃. Humidity should not exceed 50% at +40℃, with allowances for higher humidity at lower temperatures. The pollution grade is 3, and installation should be in areas without impact vibration, snow, or rain, with a vertical gradient not exceeding 5°.
Main Technical Parameters
Tables provide detailed specifications for various models, including rated insulation voltage, thermal current settings, operating currents, and motor control capacities. For example, the CJX2-09 model has a rated insulation voltage of 690V and a setting thermal current of 20A.
External and Installation Dimensions
Images and descriptions provide installation guidelines, indicating that models CJX2-09 to CJX2-32 can be installed using a 35mm standard DIN rail, while models CJX2-40 to CJX2-95 can use either 35mm or 75mm DIN rails.
Ordering Notice
When ordering, specify the model, rated control power voltage, frequency, and the quantity and combination of auxiliary contacts required.
See more

Catalog excerpts

:CJX2-09~95 Series AC Contactor-1

Contactor CJX2-09~95 Series AC Contactor 1.APPLICATION RANGE CJX2 series AC Contactor is mainly used in the circuit of AC 50Hz or 60Hz, rated operating voltage up to 690V, rated operating current up to 95A, for the use of remotely connecting and breaking, it also can be connected with thermal relay combined into electromagnetic starter to protect the circuit’s over-load of operation. Contactor can also be equipped with the building block type auxiliary contacts group, air delay contact, mechanical interlock mechanism, etc. accessories to combine into delay contactor, directional contactor, and star-delta starter. Product confirms to: GB14048.4, IEC60947-4-1 etc. standards. 2.Model and its implication CJ X 2 10 indicates: contactor that is 32A and below, its contact is 3P+NO 01 indicates: contactor that is 32A and below, its contact is 3P+NC 11 indicates: contactor that is 40A and above, its contact is 3P+NO+NC 04 indicates: contactor that is 25A and below, its contacts is 4P 08 indicates: contactor that is 25A and below, its main contacts is 2P+2R P is the main normal open contact, R is the main normal close contact (NO-normal open auxiliary contact, NC- normal close auxiliary contact) Rated operating current Design serial No. Miniature AC Contactor (Sideward installation type/side mounted) Quantity of NC contact Quantity of NO contact Auxiliary contactor group Quantity of NC contact Quantity of NO contact Auxiliary contactor group D 20 indicates the scope of delay is 0.1~3s 22 indicates the scope of delay is 0.1~30s 24 indicates the scope of delay is 10~180s 2 is delay when electrified 3 is delay when interruption of power supply

 Open the catalog to page 1
:CJX2-09~95 Series AC Contactor-2

3.APPLICATION ENVIRONMENT CONDITION 3.1 Altitude height of Installation places does not exceed 2000m 3.2 Ambient temperature Up limitation of ambient temperature does not exceed +40℃; Average value in 24h of ambient temperature does not exceed +35℃. The low limitation of ambient temperature does not lower than -5℃. 3.3 Condition of atmosphere 3.3.1 Humidity When it is the highest temperature +40℃, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20 ℃ , and it should take special...

 Open the catalog to page 2
:CJX2-09~95 Series AC Contactor-3

CJX2-09~95 Series AC Contactor Table 1 Rated insulation voltage V Setting thermal current (≤40℃) A Rated operating current Max. current when connecting A Capacity of AC-3 control three-phase squirrel cage type motor kW Max. current when Main times/h Mechanical life 3600 times/h AC-4 ten 20 thousand times/h Mechanical life times/h AC-3 ten 200 thousand times/h Mechanical life ten thousand times/h Pcs Flexible wire with cold-press terminal Single hard wire Flexible wire without cold-press

 Open the catalog to page 3
:CJX2-09~95 Series AC Contactor-4

Contactor CJX2-09~95 Series AC Contactor Table 3 Maximum Rated life million thousand times times/s hard wire, its cross section is 15~25mm2 Table 4 Maximum Rated Delay Temperature Terminal Connected minimum life times nical life load times/s Stability error of delay: delay average value after action of 2.5 *106 times/setting value error when beginning

 Open the catalog to page 4
:CJX2-09~95 Series AC Contactor-5

Contactor CJX2-09~95 Series AC Contactor CJX2-40~95 Installed by 35mm or 75mm standard DIN rail Installed by 35mm standard DIN rail Rated control power voltage Us Quantity of Auxiliary contacts and its combination

 Open the catalog to page 5

All PEOPLE ELE. APPLIANCE GROUP CO., LTD. catalogs and technical brochures

  1. DZ47-63

    2  Pages

  2. LXP1

    2  Pages

  3. RDQ1

    6  Pages

  4. RDX30LE-32

    2  Pages

  5. RDX6LE-40

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.