CJX1 Series AC Contactor

CJX1 Series AC Contactor

CJX1 Series AC Contactor

Product catalog summary
Application Range
CJX1 Series AC contactor is designed for AC circuits of 50/60Hz with a rated operating voltage up to 690V and a rated current up to 400A for AC-3 usage category. It is suitable for remote circuit connection and disconnection and can be combined with JRS2 (3UA) for overload protection. It complies with GB14048.4 and IEC60947-4-1 standards.
Model and Implication
The model CJX1 is structured with auxiliary contact combinations as detailed in Table 1. The default auxiliary contact combination is "2NO 2NC", with options for "3NO 3NC" or "4NO 4NC" for currents above 32A.
Application Environment Condition
  • Installation altitude should not exceed 2000m.
  • Ambient temperature should not exceed +40℃, with a 24-hour average not exceeding +35℃, and not lower than -5℃.
  • Humidity should not exceed 50% at +40℃, with allowances for higher humidity at lower temperatures.
  • Pollution grade is 3.
  • Installation should be in areas without impact vibration, snow, or rain, with a vertical gradient not exceeding 5°.
  • Installation category is III.
Main Technical Parameters
The CJX1 series offers various models with different rated operating currents and control power for both AC-3 and AC-4 categories at 380V and 660V. The rated insulation voltage is 690V, and the contactor coil operates reliably within 85%-110% of the rated control power voltage.
External and Installation Dimensions
Dimensions vary across models, with detailed specifications provided in tables and diagrams for models CJX1-9 to CJX1-475.
Ordering Notice
Orders should specify the model, quantity, rated control power voltage, frequency, and auxiliary contact combinations.
See more

Catalog excerpts

CJX1 Series AC Contactor-1

Contactor CJX1 Series AC Contactor CJX1 Series AC contactor is suitable for the circuit of AC 50 (or60)Hz, rated operating voltage to 690V, the rated current up to 400A when the usage category of AC-3, rated operating voltage is 380V, for remotely connecting and breaking the circuit, and it can be combined with JRS2 (3UA) into electromagnet starter to protect the circuit’s over load produced by operation. This product confirms to: GB14048.4, IEC60947-4-1, etc. standards Quantity and combination of auxiliary contact (table 1) Specification code (Rated operating current when the usage category is AC-3, rated operating voltage is 380V) Design serial No. Miniature AC Contactor Note: 1. The default combination of auxiliary contact is “2NO 2NC” 2. Auxiliary contact for above 32A can be: “3 NO 3NC” or “4NO 4NC” 3.1 Altitude height of Installation places does not exceed 2000m 3.2 Ambient temperature Up limitation of ambient temperature does not exceed +40 °C; Average value in 24h of ambient temperature does not exceed +35 C. The low limitation of ambient temperature does not lower than -5C. 3.3 Condition of atmosphere 3.3.1 Humidity When it is the highest temperature +40 C, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20 C, and it should take special measurements when there occurring condensation due to the temperature variation. 3.3.2 Pollution grade: 3 3.4 Installation condition Installing at the places that without impact vibration and without snow or rain; up terminal connects power, and the low terminal connects the load; the gradient between the vertical and the product does not exceed 5° www.peopleelectric.com [email protected]

 Open the catalog to page 1
CJX1 Series AC Contactor-2

Contactor CJX1 Series AC Contactor Rated operating current Ie (A) Control power Pe (kW) Setting thermal current >Ith frequency times/h AC- Mechanical life (ten thousand 1000 Suited fuse specification (RT16) A 4.2 Rated control power voltage Us of contactor when AC 50/60Hz: 36/42, 48/58, 110/132, 127/152, 220/264, 380/456 4.3 The coil of contactor can reliably pull-in when it is at 85%—110% of rated control power voltage, and reliably release at 20%—75% of rated control power voltage. 4.4 Rated insulation voltage of auxiliary circuit (Ui) is 380V, setting thermal current (Ith) is 10A, other...

 Open the catalog to page 2
CJX1 Series AC Contactor-3

Contactor CJX1 Series AC Contactor Contactor CJX1 Series AC Contactor 5.2 External and installation dimension for CJX1-45~140 to see picture 2 and table 5 picture 2External and installation dimension for CJX1-45~140 Table 5 a max b c max d e max f O www.peopleelectric.com [email protected]

 Open the catalog to page 3
CJX1 Series AC Contactor-4

Contactor CJX1 Series AC Contactor Table 6 O 8 10.5 10.5 Model a max b c max d e max g Rated control power voltage Us □ 36/42V, □ 48/58V, □ 110/132V, □ 127/152V, □ 220/264V, D380/456V Frequency O 50Hz O 60Hz Quantity of Auxiliary contacts ^22 O 33 O 44 and its combination www.peopleelectric.com simon@chinapeo

 Open the catalog to page 4

All PEOPLE ELE. APPLIANCE GROUP CO., LTD. catalogs and technical brochures

  1. DZ47-63

    2  Pages

  2. LXP1

    2  Pages

  3. RDQ1

    6  Pages

  4. RDX30LE-32

    2  Pages

  5. RDX6LE-40

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.