CJX1 Series AC Contactor
4Pages

{{requestButtons}}

Catalog excerpts

CJX1 Series AC Contactor - 1

Contactor CJX1 Series AC Contactor CJX1 Series AC contactor is suitable for the circuit of AC 50 (or60)Hz, rated operating voltage to 690V, the rated current up to 400A when the usage category of AC-3, rated operating voltage is 380V, for remotely connecting and breaking the circuit, and it can be combined with JRS2 (3UA) into electromagnet starter to protect the circuit’s over load produced by operation. This product confirms to: GB14048.4, IEC60947-4-1, etc. standards Quantity and combination of auxiliary contact (table 1) Specification code (Rated operating current when the usage category is AC-3, rated operating voltage is 380V) Design serial No. Miniature AC Contactor Note: 1. The default combination of auxiliary contact is “2NO 2NC” 2. Auxiliary contact for above 32A can be: “3 NO 3NC” or “4NO 4NC” 3.1 Altitude height of Installation places does not exceed 2000m 3.2 Ambient temperature Up limitation of ambient temperature does not exceed +40 °C; Average value in 24h of ambient temperature does not exceed +35 C. The low limitation of ambient temperature does not lower than -5C. 3.3 Condition of atmosphere 3.3.1 Humidity When it is the highest temperature +40 C, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20 C, and it should take special measurements when there occurring condensation due to the temperature variation. 3.3.2 Pollution grade: 3 3.4 Installation condition Installing at the places that without impact vibration and without snow or rain; up terminal connects power, and the low terminal connects the load; the gradient between the vertical and the product does not exceed 5° www.peopleelectric.com simon@chinapeople.com

Open the catalog to page 1
CJX1 Series AC Contactor - 2

Contactor CJX1 Series AC Contactor Rated operating current Ie (A) Control power Pe (kW) Setting thermal current >Ith frequency times/h AC- Mechanical life (ten thousand 1000 Suited fuse specification (RT16) A 4.2 Rated control power voltage Us of contactor when AC 50/60Hz: 36/42, 48/58, 110/132, 127/152, 220/264, 380/456 4.3 The coil of contactor can reliably pull-in when it is at 85%—110% of rated control power voltage, and reliably release at 20%—75% of rated control power voltage. 4.4 Rated insulation voltage of auxiliary circuit (Ui) is 380V, setting thermal current (Ith) is...

Open the catalog to page 2
CJX1 Series AC Contactor - 3

Contactor CJX1 Series AC Contactor Contactor CJX1 Series AC Contactor 5.2 External and installation dimension for CJX1-45~140 to see picture 2 and table 5 picture 2External and installation dimension for CJX1-45~140 Table 5 a max b c max d e max f O www.peopleelectric.com simon@chinapeople.com

Open the catalog to page 3
CJX1 Series AC Contactor - 4

Contactor CJX1 Series AC Contactor Table 6 O 8 10.5 10.5 Model a max b c max d e max g Rated control power voltage Us □ 36/42V, □ 48/58V, □ 110/132V, □ 127/152V, □ 220/264V, D380/456V Frequency O 50Hz O 60Hz Quantity of Auxiliary contacts ^22 O 33 O 44 and its combination www.peopleelectric.com simon@chinapeo

Open the catalog to page 4