General Information
Aquaflex 64 is an ultrafiltration module designed for producing process and potable water. It is typically used for filtering surface water, potable water, and wastewater treatment plant effluent. The module operates in a feed-and-bleed mode with minor crossflow or dead-end mode, incorporating regular backwash and chemically enhanced backwash.

Membrane Characteristics
The membrane is hydrophilic, made from a blend of polyvinylpyrrolidone and polyethersulfone, with a nominal pore size of 20 nm. It features an asymmetric/microporous structure, offering high performance and excellent anti-fouling properties. The membrane achieves a 99.9999% reduction of bacteria and a 99.99% reduction of viruses.

General Solvent Resistance
The membrane shows strong resistance to acids and bases, moderate resistance to aliphatic alcohols and hydrocarbons, and poor resistance to organic esters, ketones, ethers, halogenated hydrocarbons, aromatic hydrocarbons, and polar organic solvents.

Cleaning Chemical Resistance
For cleaning, the membrane can withstand sodium hypochlorite, chlorine dioxide, and hydrogen peroxide within specified limits. It is advised to minimize exposure to oxidizing agents to extend membrane life.

Operating Specifications
The maximum system, trans-membrane, and backflush pressures are all 300 kPa (43 psi). The temperature range for operation is 0-40°C (32-104°F).

Technical Specifications
The membrane element has a dry weight of approximately 34 kg and a filled weight of 66 kg. It is constructed with PVC housing, PVC/PP flow distributor, PU resin potting, and PES/PVP membrane.

Storage
Membrane modules should be stored in a dry, ventilated place between 0 and 40°C, away from heat and sunlight. The shelf life is 6 months under proper storage conditions. For long-term storage, membranes should be disinfected and kept filled with a storage solution.

Recommendations
To maximize membrane life, avoid sudden temperature changes and adhere to specified limits for pH, concentration, pressure, and temperature during operation and cleaning. Backwash water should be of UF permeate quality, and backwash pumps should be made of non-corroding materials.
See more

Catalog excerpts

Aquaflex 64-1

X-FLOW AQUAFLEX 64 ULTRAFILTRATION MEMBRANE MEMBRANE ELEMENT DATASHEET AQUAFLEX HP ARTICLE CODE : 22E1FL895H GENERAL INFORMATION CLEANING CHEMICAL RESISTANCE Aquaflex 64 is an ultrafiltration module, used for production of process and potable water. Typical applications are the filtration of surface water, potable water and WWTP effluent. Mode of operation is feed-and-bleed with a minor crossflow or dead-end mode with regular backwash (permeate only) and chemically enhanced backwash. Sodium Hypochlorite - Typical 200 ppm, at ≤ 40 ºC at ≥ pH 10 - Maximum 500 ppm - 250.000 ppm hours cumulative; ≥ pH 10 GENERAL SOLVENT RESISTANCE Hydrogen Peroxide - Typical 200 ppm, at ≤ 40 ºC - Maximum 500 ppm - 350.000 ppm hours cumulative Since the resistance of the membrane to solvents strongly depends on the actual process conditions, the indications given below should only be considered as guideline. Acids ++ Bases ++ Organic esters, ketones, ethers Aliphatic alcohols + Aliphatic hydrocarbons + Halogenated hydrocarbons -Aromatic hydrocarbons -Polar organic solvents -Oils ++ Chlorine Dioxide - Typical 1 ppm, at ≤ 40 ºC - Maximum 2 ppm - 90.000 ppm hours cumulative; pH 11 Note: The above figures for oxidant contact represent the membrane resistance to each individual oxidizing agent. The total combined exposure for Sodium Hypochlorite and Chlorine Dioxide will be calculated as follows: Combined exposure (NaOCl + ClO2) = 2.6 x Exposure to ClO2 (in ppm hours)+ Exposure to NaOCl (in ppm hours) < 250.000 ppm hours As a good working practice and in order to maximise the lifetime of the membrane it is advised to reduce the membrane exposure to oxidising agents to a minimum. Exposure limits are also affected by temperature, pH and the presence of metals. In order not to exceed maximum exposure limits, membranes must be preserved free of any oxidising agent when the plant is stopped. Acids Hydrochloric Acid Nitric Acid Sulphuric Acid Phosphoric Acid Acetic Acid Citric Acid pH > 2 during filtration pH > 1 during cleaning Bases Sodium Hydroxide (<4%) ++ Potassium Hydroxide (<4%) + + pH < 12 during filtration pH < 13 during cleaning MEMBRANE CHARACTERISTICS • Hydrophilic membrane composed of a blend of polyvinylpyrrolidone and polyethersulfone • A nominal pore size of 20 nm • Structure asymmetric/microporous • High performance and a very good antifouling behaviour • Typical permeate quality SDI<3, turbidity <0,1 NTU • Membrane filtration provides 99.9999% (LOG6) reduction of bacteria (Pseudomonas diminuta) and 99.99% (LOG 4) reduction of virus (MS2 colifages) by mechanical means. EPA Est. No. 090374-NLD-001 ADVANCED FILTRATION Membrane diameter [mm/mil] Effective membrane area [m²/ft²] Feed connection D0 [mm/Inch] Module length L0 [mm/Inch] Permeate connection d0 [mm/Inch]

 Open the catalog to page 1
Aquaflex 64-2

X-FLOW AQUAFLEX 64 ULTRAFILTRATION MEMBRANE MEMBRANE ELEMENT DATASHEET OPERATING SPECIFICATIONS Max. system pressure Temp. range TECHNICAL SPECIFICATIONS Weight Specifications Dry weight of membrane element ca. 34 kg [75 lbs] Membrane element filled with water ca. 66 kg [145 lbs] Materials of Construction Housing PVC white Flow distributor PVC/PP Potting PU resin Membrane PES/PVP • Backwash water should be free of particulates and should be of UF permeate quality or better • Backwash pumps should preferably be made of non-corroding materials, e.g., plastic or stainless steel. If compressed air...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.