Cable and Wire Management
32Pages

{{requestButtons}}

Catalog excerpts

Cable and Wire Management - 1

Cable and Wire Management EQUIPMENT PROTECTION

Open the catalog to page 1
Cable and Wire Management - 2

FLEXIBLE, VERSATILE WIRE AND CABLE PROTECTION Cables and wiring play a significant role as the main arteries for energy and control commands in mechanical and systems engineering. Hoffman offers a large selection of wireways that guarantee lasting protection for cables against dust, dirt, moisture, oil, chemicals, corrosion and mechanical damage. They are assembly-friendly, flexible and easyto-use.

Open the catalog to page 2
Cable and Wire Management - 3

Cable and Wire Management

Open the catalog to page 3
Cable and Wire Management - 4

LAY-IN WIREWAY ^►PENTAIRLAY-IN WIREWAY, NEMA TYPE 12 INDUSTRY STANDARDS UL 870 Listed; File No. E27524 NEMA/EEMAC Type 12 JIC standards EGP-1 -1967 and EMP-1-1967 CSA, File No. 42184, Type 1 IEC 60529, IP54 APPLICATION Used primarily in industrial applications to protect wiring against exposure to oil and other contaminants, this gasketed wireway features quick-release latches for easy access and an opening on one side so wires and cables can be laid in along the entire run without pulling. Available in multiple sizes, this wireway's finish color and texture can be customized to meet...

Open the catalog to page 4
Cable and Wire Management - 5

STANDARD PRODUCT SELECTION MATRIX Description Sealing Plates* Type Sealing Plates' Qty. 64 x 64 [mm] 102 x 102 [mm] 152 x 152 [mm] 203 x 203 [mm] 305 x 152 [mm] Cutoff Fitting, Lay-In Cutoff Fitting, Not Lay-In Telescope Fitting, Lay-In Cross Fitting 90° Elbow, inside opening 90° Elbow, outside opening 90° Elbow, outside top opening 45° Elbow, inside opening 45° Elbow, outside opening Tee Fitting, outside top opening Closure Plate Drop Hanger Bracket Hanger Clockwise Transposition Section Counterclockwise Transposition Section 90° Elbow, Clockwise Transposition 90° Elbow,...

Open the catalog to page 5
Cable and Wire Management - 6

STRAIGHT SECTION Available in lengths from 152 mm to 3048 mm. LAY-IN WIREWAY STRAIGHT SECTIONS Item number Sealing Plates,Type" Sealing Plates, Qty.a aEach sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. LAY-IN WIREWAY SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Open the catalog to page 6
Cable and Wire Management - 7

CUT-OFF FITTING, LAY-IN For lengths of 229 mm to 381 mm only. Body comes in two pieces. Shorten body and cover to the desired length and weld together. Sealing Sealing Plates, Plates, type Flat ■Each sealing plate also includes one gasket and one set of screws to join sections. CUT-OFF FITTING, NON-LAY-IN For lengths up to 305 mm. Shorten body to desired length and weld on flange. This is not a "lay-in" fitting but often is used when entering an enclosure. Item number Sealing Sealing Plates, Plates, aEach sealing plate also includes one gasket and one set of screws to join...

Open the catalog to page 7
Cable and Wire Management - 8

LAY-IN WIREWAY ^►PENTAIR90-DEGREE ELBOWSBecause sections of lay-in wireway can be mounted with covers oriented in any direction, three different 90-degree elbows are available. Proper selection allows the user to maintain the same access and thereby preserve the lay-in feature for right-angle installations. TOP OPENING Item number Sealing Plates, Type" Sealing Plates, Qty." ■Each sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. INSIDE OPENING Item number Sealing Plates, Qty.a Flat Flat Flat Flat Flat aEach sealing...

Open the catalog to page 8
Cable and Wire Management - 9

Item number Sealing Plates, Type" Sealing Plates, Qty.a Flat Flat Flat Flat Flat ■Each sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association INSIDE OPENING Item number Sealing Plates, Qty.a Flat Flat Flat Flat aEach sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. OUTSIDE OPENING Item number Sealing Sealing J Plates, Typea Plates, Qty.a [mm] aEach sealing plate also includes one gasket and one set of screws to join sections. Certified by...

Open the catalog to page 9
Cable and Wire Management - 10

LAY-IN WIREWAY ^►PENTAIR TEE FITTING-TOP OPENING This fitting is used when the covers of all three branches of the wireway run are open along the same side. ■Each sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. This fitting is used when the covers of two branches are on the same side and the third is on a different side. aEach sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. The junction box has a removable panel on which terminal blocks and...

Open the catalog to page 10
Cable and Wire Management - 11

CLOSURE PLATE Used to seal the end of a wireway section or run. F22LP 90° 1 99 99 ■Each sealing plate also includes one gasket and one set of screws to join sections. This fitting permits the lay-in feature to be retained when reducing to a smaller wireway size. Certified by Canadian Standards Association. aEach sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association.

Open the catalog to page 11
Cable and Wire Management - 12

LAY-IN WIREWAY DROP HANGER Hangers are used to support a wireway run. The drop hanger is normally attached to an overhead beam or ceiling. ■Each sealing plate also includes one gasket and one set of screws to join sections. BRACKET HANGER Hangers are used to support a wireway run. The bracket hanger can be used for wall, floor or ceiling installations. Item number When wireway enters an enclosure, a box connector should be used on the inside of the enclosure to ensure a tight seal. F44LB 90° 1 137 137 aEach sealing plate also includes one gasket and one set of screws to join...

Open the catalog to page 12
Cable and Wire Management - 13

LAY-IN WIREWAY These fittings are used when it is necessary to rotate the open side of the wireway run by 90 degrees and still retain the lay-in feature. Item number Sealing Plates, Sealing Plates, Type" Qty.a aEach sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. Sealing Plates, Qty.a ■Each sealing plate also includes one gasket and one set of screws to join sections. Certified by Canadian Standards Association. Item number Sealing Plates, Type* Sealing Plates, Qty.a aEach sealing plate also includes one...

Open the catalog to page 13

All NVent Schroff GmbH catalogs and technical brochures

  1. Varistar MIL

    6 Pages

Archived catalogs

  1. ACCESSPLUS

    2 Pages

  2. Epcase

    12 Pages

  3. Novastar

    2 Pages

  4. IT-News 2009

    2 Pages