STRIASOL HD 59 NF-1

PEINTURES REVETEMENTS Page 1/3 Maestria [V PEINTURES & SYSTEMES DEFINITION Two-component epoxy paint, odorless, water-diluable, semi-gloss. INTENDED USES STRIASOL HD 59 NF is intended for the floors and walls of: - technical local, - agro-food production sites, - parking lots, It's use particularly recommended where solvent-based paints can not be used. -is permeable to water vapor, and antidust -has good mechanical properties and chemical resistance (consult our technical department) as well as a good resistance to abrasion. - galvanized steel or steel previously prepared and printed using a suitable primer layer, - old paintings (in any case: imperatively consult our technical services). Note: the properties of the film, apart from its appearance, are not affected by actinic radiation To obtain an antislippery surface or a nonskid surface it is necessary to use an additive or to sprinkle fillers on the surface , consult our Technical Department. TECHNICAL DATAS Dry film finish Colour(s) Number of components Mixing ratio by weight Mixing ratio by volume Specific gravity Solids weight Solids volume Induction time at 20°C Pot life of mixing Temperature of product for application Theoritical coverage Practical spreading rate Semi glossy According to colour cards SOL, RAL/AFNOR 2 5 minutes, before use 1h30 at 20°C 45 minutes at 30°C between 15 and 30 °C 6,0 m2/ kg soit 170 g / m2 Depends on the surface, the ambient conditions and the application equipment Water (12 a 15%) Pour toute autre information, visitez notre site internet : www.maestria.fr Contact : [email protected]

 Open the catalog to page 1
STRIASOL HD 59 NF-2

PEINTURES REVETEMENTS Page 2/3 INSTRUCTIONSSurface preparation Galvanised Steel : After sweep blasting, apply a coat of EPODUX PRIMER 61-134 v01 depending on the painting schedule and the recommendations set forth in our technical data sheet. Concrete : in compliance with recommendations set forth in DTU 59-3 or DTU 54-1 concerning the preparation and quality of flooring before painting operations : dry surface, clean, polluant free, showing sufficient roughness to enable the coating adherence. Steel : After grease removal/cleaning operations, abrasive blast cleaning to Sa 2 1/2 (according to...

 Open the catalog to page 2
STRIASOL HD 59 NF-3

PEINTURES REVETEMENTS Page 3/3 Store at 20°C, 24 hours before Ambient temperature Ambient humidity Substrate humidity Substrate temperature : Minimum : 10°C / Maximum : 30°C 80% maximum 4% maximum Must be greater than 10°C and 3°C above dew point in order to prevent condensation DRYING / OVERCOATING TIME PEINTURES & SYSTEMES Laboratoire Recherche & Developpement - Usine - Administration Z.I. -1, rue Denis Papin - 09100 PAMIERS - Tel. 05 61 67 97 40 - Fax : 05 61 67 05 47 Contact: [email protected] Site internet: www.maestria.fr La presente fiche descriptive a pour but d'informer notre clientele...

 Open the catalog to page 3

All PEINTURES MAESTRIA catalogs and technical brochures

  1. VERNIKAR

    2  Pages

  2. AQUAPORE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.