Overview: The PCI3860 is a high-temperature pressure transmitter designed for hygienic applications in the food processing industry, capable of operating at media temperatures up to 150°C.
Electrical Connection: The device uses a 2-wire connection with pin 1 for supply and pin 2 for 4-20mA output.
Technical Characteristics:
  • Pressure Range: -1 bar to 0-400 bar
  • Pressure Reference: Gauge
  • Over Pressure: 1.5 times the rated pressure
  • Span: 4-20mA
  • Zero Offset: Less than +1% FSO
  • Span Tolerance: Less than +1% FSO
  • Non-linearity/Hysteresis: Less than +0.3% FSO
  • Repeatability: Less than +0.1% FSO
  • Long Term Stability: Less than +0.2% FSO over 6 months
  • Supply Voltage: 17-30Vdc
  • Reverse Polarity Protection: Yes
  • Load Driving Capability: 1150Ω at 36Vdc
  • Output Short Circuit Protection: No damage
  • Insulation Resistance: 100M Ohms at 100Vdc
  • Adjustment: +10% FSO for Zero and Span
  • Material Compatibility: 316 Stainless Steel
  • Operating Temperature Range: -10 to +150°C (Media), -20 to +80°C (Ambient)
  • Storage Temperature Range: -20 to +90°C
  • Thermal Effects: Less than +0.06% FSO/°C for both zero and sensitivity
  • Vibration Tolerance: 10g’s to 50 Hz
  • Mechanical Shock Tolerance: 15g’s (11mS)
  • Operating Humidity: 95% RH
  • Pressure Connection: ½” BSP male (others available on request)
  • Enclosure Connection: DIN Plug + socket to DIN43650
  • Enclosure Rating: IP65
  • Weight: 1500 grams
Options and Accessories: Mounting with diaphragm seal is available.
Ordering Information: Specify model and range, e.g., PCI3860, 0-10 bar.
See more

Catalog excerpts

Pressure Transmitter with Cooling Coil-1

Data sheet Date Page HIGH TEMPERATURE TRANSMITTER PCI3860 The PCI3860 pressure transmitter has been designed specifically to meet the demand of high temperature food processing applications where a hygienic flush diaphragm is required. This model will operate at media temperatures of upto 150 C. TECHNICAL CHARACTERISTICS Pressure range: -1 bar to 0-400 bar Pressure reference: Gauge Over pressure: 1.5 x rated pressure Span: 4-20mA Type: 2 wire Zero offset:: <+1% FSO Span tolerance: <+1% FSO Combined non-linearity/hysteresis: <+ 0.3 % F.S.O Repeatability: <+ 0.1% F.S.O Long term stability: <+ 0.2% F.S.O / 6 months Supply voltage: 17-30Vdc Supply voltage effects; 3uA/V Reverse polarity: Protected Load driving capability: 1150Ω@ 36 vdc Output short circuit (to ground): No damage Insulation Resistance: 100M Ohms @ 100Vdc elec conn to case Adjustment: + 10% FSO Zero and Span Pressure media compatible with: 316 Stainless Steel Operating temperature range: -10 to +150 degC Media -20 to + 80 degC Ambient Storage temperature range: -20 to +90 degC Thermal effect zero: <+0.06% FSO/degC Thermal sensitivity: <+ 0.06% FSO/degC Vibration tolerance: 10g’s to 50 Hz Mechanical shock tolerance: 15g’s (11mS) Operating humidity: 95% RH Pressure connection: ½ “ BSP male (Others on request) Enclosure connection: DIN Plug + socket to DIN43650 Enclosure rating: IP65 Weight: 1500 grams OPTIONS AND ACCESSORIES • Mounting with diaphragm seal HOW TO ORDER Please specify: model, range Example : PCI3860, 0-10 bar _______________________________________________________________________________________________ PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, Tel: +44 (0) 1704 509090, Fax: +44 (0) 1704 509091, email: [email protected], Website: www.pci-instruments.com (Specifications are subject to change without notice)

 Open the catalog to page 1

Archived catalogs

  1. Thermowells

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.