video corpo

In Head Temperature Transmitter with HART UP200
2Pages

{{requestButtons}}

Catalog excerpts

In Head Temperature Transmitter with HART UP200 - 1

Data sheet Date Page IN HEAD TEMPERATURE TRANSMITTER WITH HART UPLINK 200 OUTPUT CURRENT PRESET For ease of system calibration and commissioning the output can be set to a pre-defined level anywhere within the (4 to 20) mA range. Hart® Registered trademark of the HART communication Foundation. The UP200 has the HART communications protocol which allows the user to quickly and easily download information or interrogate the device enabling the following: • • • • • Simple re-ranging of the sensor type and range. Easy on site re-calibration. Operation with proprietary software packages such as AMS Plant Web™ and Conerstone™ Remote configuration on the 4 to 20) mA loop with hand held communicator or with a PC & HART modem Online Digital communication concurrent with a (4-20) mA Analogue signal. In head transmitters can be applied in all areas of process automation. They make sure that the transmitted process temperature is both accurate and secure. It also means that the sensitive sensor cables no longer need to be connected to the control system. SPECIFICATIONS @ 20º C Input Types Pt100, Thermocouple, mV or Slidewire. (Ni100, via Custom[X]*¹ facility) Time Constant (Filter off) 0.5 s (to 90 % of final value) Filter Factor Off/ selectable between 1 s and 32 s or Adaptive Warm-up Time 120 s to full accuracy Input/Output Breakdown Isolation 500 VAC ENVIRONMENTAL Operating Range (-40 to 85) °C Storage Temperature (-50 to 85) °C Humidity Range (0 to 95) % (non condensing) APPROVALS EMC BS EN61326 Hazardous Area ATEX II1GEExia IICT4-T6 FM FM3610-IS/I/1/ABCD/T4 OUTPUT Maximum Output Load [(Vsupply-10)/21.5] KI, 250 I minimum loop load. Supply voltages over 30 V a minimum loop load of 500 I is necessary. Burnout Levels Low 3.75 mA, High 21.5 mA Input Out of Range Low 3.8 mA, High 20.5 mA Output Range (4 to 20) mA, Min. 3.75 mA, Maximum 21.5 mA Accuracy ± 5 LA Thermal Drift 1 LA/ °C Supply Voltage (10 to 40) VDC Supply Voltage Effect 0.2 LA/ V Hart TrimDac function available. ENHANCED FEATURES ENCLOSURE Material ABS Flammability SEI UL94-V0 USER CALIBRATION In addition to sensor referencing, user offset and current output trimming is possible via the HART commands. CUSTOM LINEARISATION The [X]*¹ facility allows the UP200 to be programmed with a custom linearisation to suit non standard sensors or sensors with unusual or unique characteristics. SENSOR BURN OUT DETECTION If any sensor wire is broken or becomes disconnected the UP200 output will automatically go to its user defined level (upscale or downscale). This happens irrespectively of which wire is broken. INPUT SENSORS & RANGES Pt100 (RTD) 2, 3 or 4 Wire Sensor Range (-200 to -850) °C (18 to 390) I Minimum Span 25 °C Linearisation BS EN 60751, BS 1904, DIN 43760, JIS1604, CUSTOM [X]*¹ Max Lead Resistance 50 I per leg (balanced for 3 wire) Basic Measurement Accuracy*² 0.01 % FRI*³ ± 0.07 % rdg RTD Excitation Current (300 to 500) LA Thermal Drift Zero 0.008 °C/°C Span 0.01 %/°C THERMOCOUPLE _______________________________________________________________________________________________ PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, Tel: +44 (0) 1704 509090, Fax: +44 (0) 1704 509091, email: sales@pci-instruments.com, Website: www.pci-instruments.com (Specifications are subject to change without notice)

Open the catalog to page 1
In Head Temperature Transmitter with HART UP200 - 2

Data sheet Date Page Type Range ºC Minimum Span ºC TC Type K -200 to 1370 50 TC Type J -200 to 1200 50 TC Type T -210 to 400 25 TC Type R -10 to 1760 100 TC Type S -10 to 1760 100 TC Type E -200 to 1000 50 TC Type L -100 to 600 25 TC Type N -180 to 1300 50 TC Type [X]3 User defined Linearisation BS EN 60584-01, BS 4937, IEC 584-1 Basic Measurement Accuracy*² 0.04 % FRI*³ ± 0.04 % rdg or 0.5 °C (whichever is greater) Cold Junction ± 0.5 °C tracking 0.05 °C/°C range (-40 to 85) °C Thermal Drift Span 0.01 %/°C MILLIVOLTS Input Voltage source Range (-10 to 75) mV Characterisation Linear, Custom...

Open the catalog to page 2

All PCI INSTRUMENTS LTD catalogs and technical brochures

  1. TE1000P

    1 Pages

  2. TTS83

    1 Pages

  3. HLP280

    1 Pages

  4. HLP250

    2 Pages

Archived catalogs

  1. Thermowells

    5 Pages