2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ...
16Pages

{{requestButtons}}

Catalog excerpts

2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 1

With threaded horizontal port inlet, outlet and vent/test connection on the left hand side. The venting bonnet is positioned on the top and the isolating bonnet on the front. Standard connection Drain Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, email: SaleS@pci-instrumentS.COm, WebSite: WWW.pci-instrumentS.COm (Specifications are subject to change without notice)

Open the catalog to page 1
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 2

With threaded vertical port inlet and female outlet, The vent/test connection is positioned on the front side. The venting bonnet is positioned on the right hand side and the isolating bonnet on left hand side. Drain Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, email: sales@pci-instruments.com, Website: www.pci-instruments.com (specifications are subject to change without notice)

Open the catalog to page 2
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 3

With threaded horizontal port inlet and outlet and vent/test connection on the right hand side. The venting bonnet is positioned angular on the top and the isolating bonnet on the front. VENT VALVE Plugged vent Standard connection Product Process side Instrument side Vent/Test Drain Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, email: SaleS@pci-instrumentS.COm, WebSite: WWW.pci-instmmentS.COm (Specifications are subject to change without notice)

Open the catalog to page 3
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 4

With the vent is positioned near the male instrument connection side. INSTRUMENT CONNECTION PROCESS CONNECTION Standard connection Drain Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, email: sales@pci-instruments.com, Website: www.pci-instruments.com (specifications are subject to change without notice)

Open the catalog to page 4
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 5

With threaded vertical port inlet and outlet. The vent/test connection is positioned on the front side. The drain bonnet is positioned on the right hand side and the isolating bonnet on the left hand side. Standard connection Remote or direct mounting by means of threaded connections. Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, email: SaleS@pci-instrumentS.COm, WebSite: WWW.pci-instmmentS.COm (Specifications are subject to change without notice)

Open the catalog to page 5
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 6

I With threaded horizontal port inlet, outlet and vent/test connection on the left hand side. The venting ^^^^^^^ bonnet is positioned on the top and the isolating bonnet on the front. Standard connection Drain Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn Crescent, Southport, Merseyside, PR9 9YF, UK, email: sales@pci-instruments.com, Website: www.pci-instruments.com (specifications are subject to change without notice)

Open the catalog to page 6
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 7

Valve assembly Maximum working pressure Maximum working temperature: Drain port Bracket mounting holes Chrome plating PTFE (Grafoil to be used for temperature above 240°C till 55Cfc) Type CT; Stem with conical metal tip 1/4" NPT [F]; provided with SS 316 plug Provided on stem tip and female threads of valve. Body Material Stem Type H Stem Packing H Size = Inlet x Outlet ■ Connections GH : Material test certificate GO : Hydrotest test certificate TF : Sour gas service to NACE standard MR-01-75. SG : Oxygen service, (manifolds are supplied cleaned and degreased) DS : Valves with stem having...

Open the catalog to page 7
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 8

With threaded horizontal port inlet with a Flange outlet instrument connection. A vent/test port on base. The venting bonnet is positioned on the left hand side and the isolating bonnet angular on the top. Standard connection ISOLATE VALVE Standard version specifications of model M2VF Valve assembly Maximum working pressure Maximum working temperature: Drain port Bracket mounting holes Chrome plating PTFE (Grafoil to be used for temperature above 240°C till 550°C) Type CT; Stem with conical metal tip YA NPT [F]; provided with SS 316 plug Drain Equalize Isolate PCI (Process System Solutions)...

Open the catalog to page 8
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 9

How to order : Valve Type - M2VF Body Material Stem Type H Stem Packing H Size = Inlet x Outlet H Connections GH : Material test certificate GO : Hydrotest test certificate TF : Sour gas service to NACE standard MR-01-75. SG : Oxygen service, (manifolds are supplied cleaned and degreased) DS : Valves with stem having soft conical and delrin tip rolled into the needle for gas service. MBC : Mounting bolts [ 7/16" UNF] in carbon steel To place an order simply refer to the cdes in the table. Valve Type H Body Material Q Stem TypeH Stem Packing FINAL ORDER • The weld prepared types are...

Open the catalog to page 9
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 10

With threaded horizontal port inlet on the front side and Flange outlet on the back side, test connection on the body. The isolating bonnet are positioned on the left and right hand side and the Equalizing Bonnet is Standard connection Standard version specifications of model M2VQ Valve assembly Maximum working pressure Maximum working temperature: Drain port Chrome plating PTFE (Grafoil to be used for temperature above 240PC till 55tfC) Type CT; Stem with conical metal tip 1/4" NPT [F]; provided with SS 316 plug Drain Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7 Slaidburn...

Open the catalog to page 10
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 11

How to order : Valve Type - M2VQ Body Material I Stem Type I Stem Packing H Size = Inlet x Outlet I Connections I Threads C = Carbon Steel CT p = PTFE 2F = 1/4"x Flange FF = Female x Female N = NPT to ANSI B1.20.1 S = SS 316 DS G = Grafoil 3F = 3/8"x Flange SW = Socket weld p = BSPPto BS2779 GH : Material test certificate GO : Hydrotest test certificate TF : Sour gas service to NACE standard MR-01-75. SG : Oxygen service, (manifolds are supplied cleaned and degreased) DS : Valves with stem having soft conical and delrin tip rolled into the needle for gas service. MBC : Mounting bolts [...

Open the catalog to page 11
2 VALVE MANIFOLDS M2VH, M2VT, M2VA, M2VTF, M2VS, M2VM, M2VF ... - 12

Special two valve manifold designed to accomodate threaded direct transmitters and pressure instruments with inlet at front and outlet on top, vent/test connection at front; venting bonnet at left side and isolating bonnet at right. Special two valve manifold designed to accomodate threaded direct transmitters and pressure instruments with inlet at front and outlet on top, vent/test connection at front; venting bonnet at left side and isolating bonnet at right. ( measurement differs from the model M2VR ) PROCESS CONNECTION Equalize Isolate PCI (Process System Solutions) Ltd, Unit 7...