PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 info@industrial-needs.com www.pce-instruments.com/english www.pce-instruments.com

Open the catalog to page 1
PCE-830-1 - 2

EN 61010-2-032 CAT III 600V Pollution Degree 2 Definition of Symbols: Caution: Refer to Accompanying Documents Caution: Risk of Electric Shock Double Insulation Over-voltage category III (CAT III): equipment in fixed installations. WARNING: If the power analyzer is used in a manner Not specified by the manufacturer, the protection Prov ided by the clamp meter may be impaired. Please read the following instructions before usage 1. Do not operate in wet or dusty environments. 2. Do not operate in presence of combustible or explosive gas 3. Do not touch exposed metal parts, unused terminals....

Open the catalog to page 2
PCE-830-1 - 3

Do not use the flexible current probe before you read the following instructions. 1. Do not install the flexible current probe around bare conductors carrying a voltage from 30V to 600V unless you are wearing protective clothing and glove suitable for high-voltage work. 2. Always inspect and check for any damage of the current probe assembly before usage. Do not use the flexible current probe if any damage is found. 3. Do not use the flexible current probe on circuit rated higher than 600V in installation category III.

Open the catalog to page 3
PCE-830-1 - 6

Analysis for 3P4W, 3P3W, 1P2W, 1P3W True RMS value (V123 and I123) Active Power (W, KW, MW, GW) Apparent and Reactive Power (KVA, KVAR) Power Factor (PF), Phase Angle (Φ) Energy (WH, KWH, KVARH, PFH) Current measurement from 0.1mA to 3000A, capable of analyzing IT standby power consumption to the maximum demand of a factory Display of 35 Parameters in One Screen (3P4W) Programmable CT (1 to 600) and PT (1 to 3000) Ratios Display of Overlapped Voltage and Current Waveform Average Demand (AD in W, KW, MW) Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period Harmonic Analysis to...

Open the catalog to page 6
PCE-830-1 - 8

1. Input Terminal for Neutral Line (Voltage) 2. Voltage Input Terminals for Each Phase (V1, V2, V3) 3. External DC Input (The AC adaptor must be 600V isolated) 4. Current Input Terminals for Each Phase (I1, I2, I3) 5. LCD Display 6. Buttons 7. RS-232C Window 8. Stand Holder 9. Stand 10. Battery Cover 11. Battery Compartment

Open the catalog to page 8
PCE-830-1 - 9

Press this button to exit transient detection or to exit SETUP menu. Press this button to perform transient detection. Press this button to hold the data displayed in LCD. Press this button and then REC button to record the displayed data. Press HOLD button again to continue operation. Press this button to start measurement of harmonics in magnitude.

Open the catalog to page 9
PCE-830-1 - 10

Press this button to select V1, I1, V2, I2, V3, or I3 for harmonics analysis Press this button for the voltage or current input range Press this button to enter SETUP mode and then select the parameter to be adjusted Press this button to increment value by one. Hold the button for two seconds or more to speed up the increment. Press this button to decrement value by one. Hold the button for two seconds or more to speed up the decrement. In the mode of harmonic analysis, press this button to move the cursor left to the previous order. In the mode of harmonic analysis, press this button to...

Open the catalog to page 10
PCE-830-1 - 11

indicator. In the mode of power measurement, press this button to display the phasor diagram. In the mode of harmonic analysis, press this button to display phase angle instead of magnitude. Press this button to turn the back light on. Press it again to turn the back light off. Press this button to start measurement of power parameters. Press this button to display waveform of voltage and current. Press this button to display waveform of voltage only In the mode of power parameter measurement, press this button to select appropriate system (3P4W, 3P3W, 1P2W or 1P3W). In the mode of...

Open the catalog to page 11
PCE-830-1 - 12

Down Load File: El l:iy REC DATE: 5- 7-22 10:14:50 HZ: 50 Year Month Date Hour Minute Second 2005 7 22 13 22 _42 NOTE: To setup 100A current probe as selected probe, press the SETUP button to select CLAMP. When the CLAMP is reverse video, press the ▲ or ▼ button to select 100.

Open the catalog to page 12
PCE-830-1 - 13

Ye-ar Month Date Hour Minute Second* NOTE: To setup 1000A current probe as selected probe, press the SETUP button to select CLAMP. When the CLAMP is reverse video, press the ▲ or ▼ button to select 1000.

Open the catalog to page 13
PCE-830-1 - 14

Coupling Assembly Flexible Loop Mini-DIN connector for Output Output Range Select Switch

Open the catalog to page 14
PCE-830-1 - 15

NOTE: Select the correct CLAMP in the SETUP menu. When the current probe is connected to the power analyzer, power analyzer will automatically detect the range selected. NOTE: Select the correct frequency (Hz) in the SETUP menu. WARNING: All the current probes connected to the power analyzer must be of the same model and same range. Mixed models and different ranges selected will cause incorrect result of measurement.

Open the catalog to page 15
PCE-830-1 - 16

NOTE: Please pay special attention to the flexible current probes (model 3007/3009) connected to the power analyzer. 1. Connect the flexible probe around the conductor. 2. Make sure the current flowing direction is in consistent with the arrow marked on the probe coupling. If the flexible current probe is connected in the right orientation, the correct phase will be displayed in the oscilloscope. 3. Keep the probe coupling more than 25mm away from the conductor. WARNING: Always wear appropriate gloves in operation. 12

Open the catalog to page 16
PCE-830-1 - 17

■ =ir Month D3te Hour Minute Second 7 19 13 13 19 a. Press |SETUP| button to enter setup screen. Press SETUP again to select the item for setting (the selected item will be displayed in reverse video). b. After selecting the item, press ▲ or ▼ buttons to set up its value. c. After finishing setting up, press |EXIT button to leave setup mode. 1. Select the data for download: H means harmonics; H in reverse video means HOLD screen data (if the data is the one you want, you can press |HOLp button to display the data, and press |HOLp button again to exit); P means power data which...

Open the catalog to page 17