Air Sampler PCE-AS1

Product catalog summary
Introduction
The PCE-AS1 is an advanced air sampling meter designed for assessing microbiological pollution using the impaction principle. It is ideal for clean environments such as pharmaceutical and food production facilities, adhering to the latest airborne microbial analysis standards.
Safety Information
Users must read the manual to prevent damage. The device should be used as specified, avoiding extreme conditions and unauthorized modifications. Only accessories provided by PCE should be used, and proper storage is essential when the device is not in use.
Applications
  • Pharmaceutical Industry: Monitoring laminar flow and cleanliness in clean rooms.
  • Food Industry: Detecting microbial contamination in clean rooms.
  • Hospitals: Identifying pathogenic microorganisms in critical areas.
  • Electrical Industry: Measuring particles and micro-bacterial contamination in clean rooms.
Conditions
The device operates within a temperature range of 0-35°C, relative humidity of 10-90%, atmospheric pressure of 80-110 kPa, and a maximum wind speed of 1 m/s.
Main Features
The PCE-AS1 features a bilingual interface, large data storage capacity, robust design, and compatibility with standard Petri dishes. It alerts users to unexpected power loss and has a battery life of up to 15 hours.
Technical Parameters
Key specifications include 498 micropores, a 6400 mA battery, a throughput of 100 l/min, and storage for up to 2000 measured values.
Construction
The air sampler consists of an upper part with a collecting head and a lower part with a power supply and control panel. It operates on both DC and AC power.
Instructions
  • Operation Diagram: Provides a flowchart for navigating the device's menu and settings.
  • Quick Settings: Instructions for setting measurement volume, delay time, and storage location.
  • Detailed Settings: Further customization options including backlight timing and data deletion.
  • Inserting the Petri Dish: Guidelines for preparing and inserting the Petri dish.
  • Measuring Process: Steps for conducting measurements, including sterilization and data storage.
Maintenance and Precautionary Measures
Users should avoid sampling toxic gases and ensure the device is fully charged before use. Regular cleaning with 75% alcohol is recommended to maintain device integrity.
Troubleshooting Guide
Display Issues: If the display does not switch on or remains dark, the battery may be low or the fuse faulty. Solutions include connecting the charger or replacing the fuse.
Pump Issues: If the pump does not work, check for loose cables, pump output failure, or a faulty pump. Solutions involve reconnecting cables, restoring pump output, or replacing the pump.
Flow Rate Issues: A low flow rate may be due to a low battery, clogged holes, or an excessively covered dish. Solutions include charging the battery, cleaning the holes, or spreading the medium evenly.
Display Malfunction: If the display shows unclear characters or some keys do not work, the internal computer may have crashed. Reset the device by turning it off, waiting 5 seconds, and switching it back on.
See more

Catalog excerpts

Air Sampler PCE-AS1-1

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 [email protected] PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 [email protected] www.pce-instruments.com/english www.pce-instruments.com

 Open the catalog to page 1
Air Sampler PCE-AS1-3

PCE-AS1 is a modern air sampling meter that helps users assess microbiological pollution. The device uses the impaction principle when taking measurements. After air samples are taken and an incubation has occurred, the number of microorganisms can be determined. The air sampling meter must be used in a clean environment such as a pharmaceutical or food production facility. The air sampling meter meets the latest requirements for devices used for airborne microbial analysis. When samples are taken, the air particles enter through the surface of the meter. The particles then hit the surface of...

 Open the catalog to page 3
Air Sampler PCE-AS1-4

3.1 Pharmaceutical industry Recording of the laminar flow of microorganisms; Analysis of the cleanliness of a clean room; Testing the effectiveness of sterilization. 3.2 Food industry Detection of microbial contamination in the clean room according to the HACCP concept. 3.3 Hospitals Detection of pathogenic microorganisms in operating theaters, as well as in the pharmacy, storeroom or ICU. 3.4 Electrical industry Measuring particles and micro-bacterial contamination in clean rooms. • Temperature: • Relative humidity: • Atmospheric pressure: • Maximum ambient wind speed: 5 Main features English...

 Open the catalog to page 4
Air Sampler PCE-AS1-5

6 Technical parameters • Number of micropores in the collective mind: 498 • Battery: 6400 mA • Flow rate from the gathering head: 0.38 m / second (kinetic sampling) • Automatic control of the measuring volume: 10 ~ 6000 l (minimum: 10 l) • Dimensions plate: 0 70 ~ 90 * 15 mm • Storage of up to 99 parameters and 2000 measured values possible • Dimensions: 120 x 300 mm 7 Construction The air sampler consists of an upper and a lower part. The upper part consists of a collecting head, the cover of the collecting head, the device for the plate, the pump and the pump part. The power supply, the...

 Open the catalog to page 5
Air Sampler PCE-AS1-6

Operation diagram Main menu Selection of memory item (max. 99 items) Selection via “Select” key in combination with arrow keys Select a memory item previously saved Query of saved data Selection via “Select” key in combination with arrow keys Selection via “Select” key in combination with arrow keys Set volume of measurement, delay time and memory item Indication of last reading Selection via “Select” key in combination with arrow keys

 Open the catalog to page 6
Air Sampler PCE-AS1-7

Welcome screen Main menu Set delay time Reset meter to factory settings Set place to save the readings Language setting Delete collected date Save settings for measurement record Date setting Time setting Save settings for measurement record * A reset to factory settings is normally not necessary. If still desired, contact us for the password. Quick settings Press the power button, and the device automatically displays the central user interface. To get into the mode where you set the parameters for the measurement, press the "Menu" button: Setting the measuring volume: Press the “select” button...

 Open the catalog to page 7
Air Sampler PCE-AS1-8

8.3 Detailed settings To turn on the unit, press the "power" button. The indicator lights up and the device automatically performs a self-test. After the test is completed, the air sampler automatically switches to the central user interface. To specify the settings, press the "menu" button: • Setting the measuring volume: See point 8.1 of the operating instructions. Set volumes from 10 to 6000 liters in increments of 10 mm. • Setting measurement time delay: See point 8.1 of the operating instructions. The delay time can be set between 0 and 256 seconds in intervals of one second. • Setting...

 Open the catalog to page 8
Air Sampler PCE-AS1-9

Measuring process · Remove the cover from the collecting head. The collecting head should be sterilized in an autoclave at 121 ° C for 30 minutes (sterilization with a cloth with 75% alcohol is also possible). After sterilization, the cover should be placed back on the collecting head. The Petri dish should also be sterilized with 75% alcohol. Switch on the device. The display should show the current date and time settings, the battery level, the storage, the last set of the measuring volume, the delay time and other information. In the air sampler, a Petri dish with a middle diameter of Ø 70...

 Open the catalog to page 9
Air Sampler PCE-AS1-10

• Do not perform sampling with toxic corrosive gas. The device is also not for use in sour or alkaline environments. It is not allowed in areas where there is fine dust of 0.3 mg / m 3. Do not press the "sample" button before covering, because the pump can overheat and be destroyed. • Completely charge the battery before each use to prevent damage. • When the plate is inserted, it should be snug and reach the ground. • After each use, the collecting head and top should be cleaned with 75% alcohol. Then the cover must be placed again on the collecting head set. Alle PCE-Produkte sind CE...