Bearing Fault Detector-1

BEARING FAULT DETECTORS ■ Detects impacting associated with bearing faults, including spalling, cracking and lubrication problems Outputs a 4-20 mA current output signal for peak acceleration Bearing faults create metal-to-metal impacts that manifest in vibration data as high-frequency, high-amplitude peaks. Typical vibration transmitters that utilize the RMS process cannot accurately identify these peaks. As an alternative, IMI Sensors has developed two products with a 4-20 mA output that are specifically designed to identify high-frequency, high-amplitude peaks. Operates with PLC, DCS, SCADA, alarm and control systems TYPICAL APPLICATIONS Normal operation Bearings in: Onset of fault ■ Green Line: True Peak Peak Value Green Line: Captured Value Orange Line: Overall RMS Value Orange Line: Overall Value Blue Line: Analog Vibration Blue Line: Analog Vibration IECEx IECEx

 Open the catalog to page 1
Bearing Fault Detector-2

BEARING FAULT DETECTOR FUNCTIONALITY AND FEATURES Bearing Fault Detector (Model 682C05): The Bearing Fault Detector offers three simultaneous signals- raw analog voltage output, current output proportional to overall vibration and current output proportional to true peak acceleration. The signal processing begins with a 100 mV/g VAC signal from a remotely-mounting ICP® accelerometer. Output Signal Processing Spectral (FFT) analysis for fault diagnostics VAC signal is re-transmitted through the BFD’s BNC jack unprocessed Ideal indicator of faults that occur 4-20 mA Current at machine running speeds,...

 Open the catalog to page 2
Bearing Fault Detector-3

BEARING FAULT DETECTOR (MODEL 682C05) SPECIFICATIONS Channels Sampling Time Input Signal Frequency Range (Overall Vibration) Frequency Range (True Peak Acceleration) Output Signal (AC Vibration) Output Signal (Overall Vibration) Output Signal (True Peak Acceleration) Output Range (Overall Vibration-Acceleration) Output Range (Overall Vibration-Velocity) Output Range (True Peak Acceleration) Environmental Temperature Range Humidity Range (Non-Condensing) Electrical Power Required Excitation Voltage (To Sensor) (± 1VDC) Constant Current Excitation (To Sensor) (± 1mA) ANALOG OUTPUT Physical Housing...

 Open the catalog to page 3
Bearing Fault Detector-4

BEARING FAULT DETECTOR PLUS (MODEL CS649AX3) 2-pin Threaded MIL-C-5015 Connector SPECIFICATIONS Model Number Performance Sampling Time Output Signal Output Range (True Peak Acceleration) Output Range (RMS Acceleration) Output Range (Crest Factor) Output Range (Peak Acceleration with Correction) Peak Acceleration with Correction- Bearing Diameter Peak Acceleration with Correction- Bearing Rotation Speed Linearity (Loop Powered) Output Range (Crest Factor Plus) Environmental Overload Limit (Shock) Temperature Range Hazardous Area Approved Load Resistance PCB Piezotronics Inc. claims proprietary...