E-LINK 3000

E-LINK 3000

E-LINK 3000

Product catalog summary
Overview: The E LINK 3000 is a versatile weight transmitter designed for integration into industrial systems. It offers five different electronic configurations and case options to meet various system requirements. Key features include field and remote fault diagnostics, remote configuration capabilities, and compatibility with industrial regulation and supervision systems.
Key Features:
  • Remote configuration via PC or Master communication protocol.
  • Cell failure emulation with automatic recalibration.
  • Local and remote troubleshooting for load cells.
Technical Specifications:
  • Temperature Range: Operating: -10 to +50°C, Storage: -20 to +70°C.
  • Power Supply: 12 to 24 Vcc, Load cell power: 5 Vcc.
  • Input Signal Range: -5 mV/V to +5 mV/V.
  • A/D Converter: 24 bits with internal resolution over 16,000,000 points.
  • Resolution: Over 3,000,000 points per cell channel at 2 mV/V.
  • Input Sensitivity: 0.003 micronV/division.
  • Readings per Second: 0.1 to 72, depending on cell channels and digital filter value.
  • Linearity: Greater than 0.01% F.S.
  • Thermal Drift: Greater than 0.003% F.S./°C.
Communication and Connections:
  • Serial Ports: COM1: RS232, COM2: RS485 with Modbus RTU, Profibus-DP, DeviceNet, CANOpen, Modbus TCP on Ethernet.
  • Electrical Connections: Load cells and power via 7 poles removable terminal blocks, Profibus-DP via 9-pin D-sub connector, DeviceNet via 5 poles removable terminal blocks, CANOpen via 9 poles D-sub connector, Ethernet via RJ-45 connector.
Physical Dimensions: 130x100x60 mm (WxHxD) with DIN rail support.
Compliance: CE conformity with EN 61000-6-3, EN 61000-6-2 standards.
Manufacturer: Pavone Sistemi S.r.l., Italy.
Note: Specifications are subject to change without notice.
See more

Catalog excerpts

E-LINK 3000-1

Weighing Instrumentations weight transmitters Remote configuration from a PC (via software) or directly from the Master via the communication protocol Integrable in any industrial system of regulation and supervision Cell failure emulation function (excluding the weighing system with automatic recalibration) Troubleshooting on the load cells via local diagnosis and remote check 5 different cases for all system requirements 5 different electronic configurations Field and remote fault diagnostics

 Open the catalog to page 1
E-LINK 3000-2

TECHNICAL CHARACTERISTICS E LINK 3000 Temperature range: Storage temperature: Power supply: Load cell power supply: Input signal cells: A/D converter: Internal resolution: Resolution 2 mV/V: Input sensitivity: Readings per second per cell: Linearity: Thermal drift: Serial port: Electrical connections: -10 ÷ +50°C -20 ÷ +70 °C 12 ÷ 24 Vcc 5 Vcc measurement range of -5 mV/V to +5 mV/V 24 bits > of 16,000,000 points > 3.000.000 points on each cell's channel 0.003 micronV/division from 0.1 to 72 based on the number of cell's channels activated and to the value of digital filter >0.01% F.S. >0.003%...

 Open the catalog to page 2

All Pavone sistemi catalogs and technical brochures