CVF

CVF

CVF

Product catalog summary
Overview: The document provides technical specifications and features of the CVF compression load cells designed for force measurement. These load cells are built to withstand lateral loads and offer excellent linearity and precision. They are capable of handling overloads greater than 300% and are protected for use in harsh environments.
Specifications:
  • Rated Load (R.L.): 0.5 to 5000 kN
  • Combined Error: ±0.05% of Rated Output (R.O.)
  • Repeatability: ±0.02% of R.O.
  • Creep (20 minutes): ±0.02% of R.L.
  • Safe Overload: 150% of R.L.
  • Ultimate Overload: Greater than 300% of R.L.
  • Recommended Input: 2 to 15 Vdc/Vac
  • Input Resistance: 700 ±20 Ohm (350 Ohm for 1000 to 5000 kN)
  • Output Resistance: 700 ±5 Ohm (350 Ohm for 1000 to 5000 kN)
  • Insulation Resistance: Greater than 5000 M Ohm
  • Rated Output (R.O.): 2.0 mV/V ±0.1%
  • Zero Balance: Less than ±1.5% of R.O.
  • Temperature Range: -20 to +70 °C
  • Compensated Temperature Range: -10 to +50 °C
  • Temperature Effect on Zero Balance: Less than ±0.005% of R.O./°C
  • Temperature Effect on Output: Less than ±0.005% on output/°C
  • Max Load Deflection: 0.2 mm
  • Degree of Protection: IP65
  • Material: Stainless steel
  • Electrical Connection: 6 conductors
Additional Features: The load cells are available in special versions for high-temperature applications. The 2000 kN and 5000 kN capacities are made of stainless tropicalized steel.
Contact Information: Pavone Sistemi S.r.l., via Dei Chiosi, 18 - 20873 Cavenago Brianza (MB) Italy. Tel: 02 95339165, Fax: 02 9501252, Email: [email protected], Website: www.pavonesistemi.it
Note: All data is subject to change without notice.
See more

Catalog excerpts

CVF-1

Load Cells compression Overload capability greater than 300% Watertight protection for use in harsh environments Stainless steel The 2000 kN and 5000 kN capacities are made of stainless tropicalized Also available in special versions for High Temperature Predisposed to lateral loads withstand Designed for forces measurement Excellent linearity and precision

 Open the catalog to page 1
CVF-2

TECHNICAL CHARACTERISTICS CVF Rated load (R.L.): Combined error: Repeatability: Creep (20 minutes): Safe overload: Ultimate overload: Recommended input: Input resistance: Output resistance: Insulation resistance Rated output (R.O.): Zero balance: Temperature range: Compensated temperature range: Temp. effect (-10° to +50°C) on zero balance: Temp. effect (-10°C to +50°C) on output: Max load deflection: Degree of protection: Material: Electrical connection: 0.5÷5000 kN ±0.05% of R.O. ±0.02% of R.O. ±0.02% of R.L. 150% of R.L. > 300% of R.L. 2÷15 Vdc/Vac 700 ±20 Ohm (350 Ohm carrying capacity 1000÷5000...

 Open the catalog to page 2

All Pavone sistemi catalogs and technical brochures

  1. MKX ®

    2  Pages

  2. MCT 1302

    3  Pages

  3. E-LINK 3000

    2  Pages

  4. DAT 500

    2  Pages

  5. DAT 100

    2  Pages

  6. DAT 200

    2  Pages

  7. DAT 400

    2  Pages

  8. MC 382

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.