Insulated Conductor Systems FABA100
16Pages

{{requestButtons}}

Catalog excerpts

Insulated Conductor Systems FABA100 - 1

INSULATED CONDUCTOR SYSTEM FABA 100

Open the catalog to page 1
Insulated Conductor Systems FABA100 - 2

GENERAL FABA 100 insulated conductor system comply with VDE 0100. They sat- isfy today‘s requirements for conductor line safety and are protected Indoor applications only. Outdoor applications only after consultation. against accidental contact in compliance with VDE 0470, Part 1 (Safety UL approved. Please consult us when ordering. Naturally for the collector this contact protection exists only when the brushes are completely in the conductor rails. Conductor lines systems SUPPORT DISTANCE in the manual area, in which the collector moves out The maximum suspension interval between compact...

Open the catalog to page 2
Insulated Conductor Systems FABA100 - 3

JOINT CAPS Joint caps protect the conductor rail against accidental contact and separate the rails mechanically (switches, elevating stations, etc.). Joint caps are available with and without feed terminals. ISOLATING ASSEMBLIES Isolating assemblies interrupt the conductor system electrically. Operationally driving over collectors for the purpose of connecting or disconnecting the power is permissible only at low power (control currents). We supply isolating assemblies with and without feed terminals for control purposes,in-feed sections, maintenance sections, etc. CURVES Insulated...

Open the catalog to page 3
Insulated Conductor Systems FABA100 - 4

PART NUMBER CODE FABA = insulated Conductor Rails 100 = Current rating in A 25 = Conductor cross section (mm2) C = Copper conductor LENGTH 5 m standard length, shorter lengths possible SUPPORT SPACING for straight sections 0.8 m in curves 0.4 m CONDUCTOR SPACING Standard = 15 mm CONDUCTOR RAILS CAN BE BENT at the factory or on the construction site with special FABA 100 curve too USE for indoor systems only, please contact us for consultation for outdoor systems (1) At phase interval of 15 mm and frequency of 50 Hz.

Open the catalog to page 4
Insulated Conductor Systems FABA100 - 5

Use: 100 A for fix point clamps, construction height 32 mm

Open the catalog to page 5
Insulated Conductor Systems FABA100 - 6

EXPANSION SECTION Note: Expansion without Jumper line suitable for max, 50 A (3) Order mounting hardware separately

Open the catalog to page 6
Insulated Conductor Systems FABA100 - 7

SUPPORT POINT CLAMP With support clamps any number of poles can be connected together. SUPPORT CLAMP FOR SCREWING ON, UP TO 8-POLE Rail interval 15 mm Production for your system on request,

Open the catalog to page 7
Insulated Conductor Systems FABA100 - 8

COLLECTORS COLLECTOR SET D-EAS suitable for funnel Phase distance; 15mm Pressure; ca. 4 N per brush PE at position 4 with 3 poles at, other arragements possible! Ground is always first contact..

Open the catalog to page 8
Insulated Conductor Systems FABA100 - 9

CONNECTING CABLE CONNECTING CABLE, DOUBLE INSULATION, HIGHLY FLEXIBLE for collectors, length: 1 m

Open the catalog to page 9
Insulated Conductor Systems FABA100 - 10

TERMINAL BOXES AKE for feed terminal and isolating assembly, max, 7 terminals 6 mm2 2 terminals 6 mm2 pe

Open the catalog to page 10
Insulated Conductor Systems FABA100 - 11

ASSEMBLY ACCESSORIES CURVE TOOL for bending FABA 100 vertically and horizontally. Order filling rods separately. ALLEN SCREW SW 4 Type

Open the catalog to page 11
Insulated Conductor Systems FABA100 - 12

ASSEMBLY ACCESSORIESASSEMBLY HANDLE FOR JOINTS, PLUGABLE Type DEBURRING TOOL FLAT HAND FILE FSF for deburring the outer face of the profile for short sections SCREW DRIVER PH1 Type

Open the catalog to page 12
Insulated Conductor Systems FABA100 - 13

QUESTIONNAIRE Company; Date; Fon: Fax; E-mail; internet: 1. Number of conductor system installations: 2. Type of equipment to be powered: 3. Operating voltage:Volt Frequency:Hz □ Three-phase voltage □ AC voltage □ DC voltage 5. Number of conductors:_ neutral:_ control:_ ground: 6. Mounted position of conductor system: D Conductor system pendant, collector cable facing to the bottom D Conductor system pendant, lateral payout of conductor cable(1) □ Support distancem (max. 2 m) □ Other: 7. Number of consumers per system: 8. □ indoor system □ Outdoor system 9. Other operating conditions...

Open the catalog to page 13
Insulated Conductor Systems FABA100 - 16

Paul Vahle GmbH & Co. KG Westicker Str. 52 59174 Kamen Germany Tel.: +49 2307 704-0 Fax: +49 2307 704-444 info@vahle.de W2516629/00/en | 0 | Rev.02 | 02/19 | Errors and technical modification subject to change.

Open the catalog to page 16