Group: VAHLE Group
Catalog excerpts
Insulated conductor system FABA 100
Open the catalog to page 1Insulated conductor system FABA 100 General FABA 100 insulated conductor rails comply with VDE 0100. They satisfy today's requirements for conductor line safety and are protected against accidental contact in compliance with VDE 0470, Part 1 (Safety Class IP 21). Naturally for the collector this contact protection exists only when the brushes are completely in the conductor rails. Conductor lines systems in the manual area, in which the collector moves out of the conductor rail during operation, require provisions by the customer to prevent accidental contact such as blocking off or...
Open the catalog to page 3Insulated conductor system FABA 100 (General) Joint caps Joint caps protect the conductor rail at the end against accidental contact and separate the rails mechanically (switches, elevating stations, etc.). Joint caps are available with and without feed terminals. The collectors consist of impact-resistant plastic and re–inforced metal parts. The power is drawn with a carbon brush. Isolating assemblies Isolating assemblies interrupt the conductor electrically. Operationally driving over collectors for the purpose of connecting or disconnecting the power is permissible only at low power...
Open the catalog to page 4Insulated Conductor Rails FABA 100 (Technical Data) Conductor rails can be bent Support spacing Chemical and electrical values: 5 m standard length Shorter lengths possible 4 Part number code FABA = Insulated Conductor Rails 100 = Current rating in A 25 = Conductor cross section (mm²) C = Copper conductor at the factory or on the construction site with special FABA 100 curve tool For straight sections 0.8 m In curves 0.4 m Conductor spacing for indoor systems only, please contact us for consultation for outdoor systems Type Faba 100 Standard version, 0range Part No.Phase Type Faba 100...
Open the catalog to page 5Bolted Joint Feed Joints Use: 100 A for fix point clamps, construction height 32 mm Trennung mit Brückung Crimp connection, max. 2.52 14 Trennung mit 2 Einspeisungen 14-24 Trennung mit Brückungnot under power Isoling assembly Type Trennung mit 1 Einspeisung Weight kg Trennung mit 2 Einspeisungen Separation without connecting cable Separation with 1 connecting cable Separation with 2 Connectiing cable Separation with jumper cable Trennung ohne Einspeisung Trennung mit Brückung Trennung mit 1 Einspeisung Trennung mit 2 Einspeisungen Trennung ohne Einspeisung Trennung mit Brückung Trennung mit...
Open the catalog to page 6Expansion section Note: Expansion without jumper line suitable for max. 50 A Part No.Phase Expansion section Jumper cable Joint cap with or without feed terminal (used as end cap and in combination with support as fix point) Max. perpendicular and lateral offset: 2 mm in relation to one another. Please contact us for higher tolerances. Transition cap w/o 0,005 feed connection possibility Transition cap with 0,026 feed connection possibility Support for joint cap for screwing to the track, arrangement as desired depending on number of poles Support can be adjusted by ± 5 mm in direction of...
Open the catalog to page 7Support point clamp and fix point FABA 100 With support point clamps any number of poles can be connected together. Support clamp for screwing on, up to 8-pole Rail interval 15 mm Number of poles or assignment Construction height Support clamp Support clamp Note: Order mounting hardware separately Support clamp, special version, up to 10-pole Production for your system on request AFT-Profil mit Klemme Rofa-Profil mit KlemmeSiemens-Profil mit Klemme AFT-Profil mit Klemme Eisenmann-Profi Siemens-Profil mit Klemme 48
Open the catalog to page 8Collector set D-EAS suitable for funnel Phase distance: 15 mm Max. current: 30 A Lift ± 12 mm, Lateral tolerance ± 20 mm Pressure: 4 N per brush PE at position 4 with 3 poles at, other arragements possible. Ground is always first contact. Flat plug connector 6.3 x 0.8 Support rail Wear parts for collector FABA 100 60 Replacement heads for collector DEAS Type Rear replacement head 0,5 Front replacement head
Open the catalog to page 9Connecting cable Connecting cable, double insulation, highly flexible for collectors, length: 1 m Type Part No. Phase black Connecting cable, double insulation, flexible for feed joint with cable lug M6, length: 1 m Type Part No. Phase black Connecting cable Connecting cable Connecting cable Connecting cable connection line Connecting cable, double insulation, flexible for joint cap with cable lug M5, length: 1 m Type Part No. Phase black Connection line Connection line
Open the catalog to page 10Terminal boxes and brush wear indicator for FABA 100 Terminal boxes AKE for feed terminal and isolating assembly, max. 7 terminals 6 mm², 2 terminals 6 mm² PE Terminal boxes AKE for separating sections Type Brush wear indicator KVT 100 N The brush wear indicator automatically checks the brushes for wear. A pulse is triggered when a brush is worn out. Installation in front of a repair section is practical for automatic operation of a switch. Adjusted at factory. Required cutout in FS channel. Length: 80 mm, height: See table Type
Open the catalog to page 11Assembly accessories for FABA 100 Curve tool for bending FABA 100 vertically and horizontally. Order filling rods separately. Type FABA 100 curve tool 100 Filling rods 100 m in rolls Curve Profile 5 m in rods Table saw for cutting insulator and conductor profiles with length gauge. Connection: 230 Volts, 50 Hz. Type Replacement saws spare blade SB Conductor joint assembly tool For connecting with joints. Type Conductor joint assembly tool Allen screw
Open the catalog to page 12Assembly accessories for FABA 100 Assembly handle for joints, plugable Type Assembly handle Deburring tool flat hand file HRF for deburring the outer face of the profile for short sections. Type Flat hand file
Open the catalog to page 13Questionnaire Co.:_________________________________________________________ Date:_______________________________________________________ Tel.:_________________________________________________________ Fax:_________________________________________________________ Email:_______________________________________________________ Internet:_____________________________________________________ 1. Number of conductor systems:_____________________________________________________________________________________________ 2. Type of crane/machinery to be...
Open the catalog to page 14All Paul Vahle GmbH & Co. KG catalogs and technical brochures
-
vFESTOON on S-Profile
57 Pages
-
VAHLE COMPACT LINE VCL
8 Pages
-
APOS® positioning system
4 Pages
-
Festoon Systems for S-tracks
57 Pages
-
Festoon Systems for V-tracks
14 Pages
-
Cables and accessories
56 Pages
-
Spring operated cable reels
40 Pages
-
Open Conductor Systems
48 Pages
-
vDRIVE - Control Systems DCS1
12 Pages
-
Contactless Power Supply CPS®
24 Pages
-
BOK System
4 Pages
-
Enclosed Conductor Systems MKH
40 Pages
-
Enclosed Conductor Systems KSL
30 Pages
-
Enclosed Conductor Systems KBH
36 Pages
-
Compact Conductor System VKL2
12 Pages
-
VAHLE Multi Support Profile VMT
12 Pages
-
Compact Conductor Systems VKS
32 Pages
-
Compact Conductor Systems VKS10
28 Pages
-
INSULATED CONDUCTOR SYSTEMS U10
24 Pages
-
vDRIVE - Mobile Control Systems
12 Pages
-
APOS Positioning System
4 Pages
-
SMGM | SMGX Data Tramsmission
16 Pages
-
Powercom Data Transmission
4 Pages
-
Contactless Power Supply (CPS)
24 Pages
-
Charging Contacts
8 Pages
-
Multi Support Profile VMT
12 Pages
Archived catalogs
-
Enclosed Conductor System MKH
40 Pages
-
Enclosed Conductor System KBH
36 Pages
-
Compact Conductor SystemVKS, VKL
34 Pages
-
Compact Conductor System VKS10
24 Pages
-
Heavy enclosed conductor systems
12 Pages
-
Insulated conductor system
48 Pages
-
Insulated Conduxtor System U10
16 Pages
-
Battery Charging Systems
8 Pages
-
Copperhead Conductor Systems
24 Pages