Enclosed Conductor System MKH
40Pages

{{requestButtons}}

Catalog excerpts

Enclosed Conductor System MKH - 1

MACHT STROM MOBIL Enclosed Conductor System MKH

Open the catalog to page 1
Enclosed Conductor System MKH - 3

Enclosed conductor system MKH Description of the conductor system The MKH... is a totally enclosed conductor system for indoorand outdoor use. The insulated housing can accommodate different Type MKHD in 6 to 10 copper conductor version, (copper strips come as separate items as coils). Type MKHF in 6- and 8-conductor version, with preassembled copper conductors and spring loaded connectors from 40 to 100 A. Type MKHS in 6- and 8-conductor version, with preassembled copper conductors and bolted joints from 40 to 200 A. A compact design, corrosion resistance and easy installation are The MKH...

Open the catalog to page 3
Enclosed Conductor System MKH - 4

Anti-condensation sections For combined indoor/outdoor applications use anti-condensation sections. They do not interrupt electric conductors. Contact sections, turntables, switches Conductor systems with entry funnels or transfer guides see pages 20 and 21. Conductor dead sections are electrical interrupts of the conductor. Under normal operating conditions a cross over with collectors to switch the voltage off or on is only allowed with low power ratings (control current). The conductors can be seperated through air gaps (5 mm) or insulating pieces (35 mm). With the air gap the collector...

Open the catalog to page 4
Enclosed Conductor System MKH - 5

Technical Data Cross sections:(1) In case of using a neutral conductor copper pos.1 will be taken. Layout of the system on request. No. of Copper cross section mm2 conductors Phase Control-line L1, L2, L3 Ampere rating with 35 °C in A, L1, L2, L3 (1) Numbers in paranthesis apply to control line (2) Complete types e.g. MKHS 7/63 HS for 7 poles with bolted joints (3)

Open the catalog to page 5
Enclosed Conductor System MKH - 6

MKHD/MKHF/MKHS Technicall data & standard sections In case of using a neutral conductor copper pos.1 will be taken. Layout of the system on request. Type (HS with PE SS without PE) No. of Copper cross section mm conductors Phase Control-line L1, L2, L3 Ampere rating with 35 °C in A, L1, L2, L3 Standard sections Type MKHF with plug-in joints, factory assembled A-A 56,2 left side yellow (dark grey) A Type MKHD for continuous copper strips Standard section Type MKHS with bolted joints, factory assembled left side right side Standard section (1) Numbers in paranthesis apply to control line (2)...

Open the catalog to page 6
Enclosed Conductor System MKH - 7

MKHD/MKHF Types & order numbers Type MKHD with continuous copper strips, to be drawn in during installation. Type MKHF with factory assembled copper strips and plug-in joints (40 – 100 A) (1) Complete types e.g. MKHD-4000HSC for 4 m with PE, Order-No. 262 504 MKHF8/40-4000HS for 4 m with PE, Order-No. 262 114 • The last number of the order specifies the section length. Please suffix t

Open the catalog to page 7
Enclosed Conductor System MKH - 8

Type MKHS with factory assembled copper strips and bolted joints (40 - 200 A) (1) omplete types e.g. MKHS8/40-4000HSC for 4 m with PE, Order-No. 262 324 C The 4-digit number (in bold) in the type indicates the length of the section in mm. • The last number of the order specifies the section length. Pleas

Open the catalog to page 8
Enclosed Conductor System MKH - 9

MKHD/MKHF/MKHS Sections & Sealing strips HR for SI = Horizontal radius - Safety web inside HR for SA = Horizontal radius - Safety web outside 2 (5) yellow (dark grey) Min. bending radius, horizontal = 1000 mm max. length L = 3600 mm max. 120 ° ) Smallest vertical radius = on request Bearing surface of the collector green (dark grey) VRO = Vertical radius upwards VRU = Vertical radius downwards Safety web will be mounted in direction of track. Changes in measurements of curves have to be mentioned for replacement orders. Sealing strip including accessories The sealing strip is available in...

Open the catalog to page 9
Enclosed Conductor System MKH - 10

Sliding hanger Type AH-MGH AH-MGH/K Fixpoint hanger Type AH-MFH AH-MFH/K End section (MKHD) 0,3 m long Type End cap (MKHF / MKHS) Type

Open the catalog to page 10
Enclosed Conductor System MKH - 11

MKHD/MKHF/MKHS Brackets - beam Position of the fixing claw for D = 15-25 mm Position of the fixing claw for D = 6-15 mm 25 fixing claw support bracket view without Arrangement EHK with small fixing claw Attention! Make sure that hoist wheels have enough clearance. Use small claw if necessary. - rail of EHK is identical to type S1, Cat. 8 a Type(1) small fixing claw Order - No. Standard version with small fixing claw (1) e.g. HK-EHK250-KS12 → Order-No. 251720-12 for fixing claw with D=12mm Select next larger size bracket when your -beam dimension B is more than 170 mm.

Open the catalog to page 11
Enclosed Conductor System MKH - 12

MKHD/MKHF/MKHS Jointing material & End feeds 150 Joint cap, self locking (MKHD) Type Joint cap, self locking (MKHF / MKHS) End feed comes loose without powerail section. It can be mounted at the left or right hand side. Electrical connection with customer supplied cable shoes to M6 terminals. Cable gland (Dimensions see p. 33) End feed (MKHF / MKHS) End feed comes loose without powerail section. It can be mounted at the left or right hand side. Electrical connection with customer supplied cable shoes to M6 terminals. Cable gland (Dimensions see p. 33)

Open the catalog to page 12
Enclosed Conductor System MKH - 13

MKHD Line feeds Electrical connection with customer supplied cable shoes to M8 terminals. Cable gland (Dimensions see p. 33)

Open the catalog to page 13
Enclosed Conductor System MKH - 14

MKHF/MKHS Line feeds 1 50 Electrical connection with customer supplied cable shoes to M8 terminals. Photo shows MHGF Cable gland (Dimensions see p. 33) Cable gland (Dimensions see p. 33)

Open the catalog to page 14
Enclosed Conductor System MKH - 15

MKHD Line feeds 300 Electrical connection with customer supplied cable shoes to M8 terminals. Cable gland (Dimensions see p. 33)

Open the catalog to page 15
Enclosed Conductor System MKH - 16

MKHF/MKHS Line feeds 150 Electrical connection with customer supplied cable shoes to M8 terminals. Photo shows MHLS Cable gland (Dimensions see p. 33) Cable gland (Dimensions see p. 33)

Open the catalog to page 16
Enclosed Conductor System MKH - 17

MKHD/MKHF/MKHS Heating Heating cable Type We recommend a heating system for outdoor installations and installations in humid plants. The heating consists of arrangement two heating cables as per drawing. Attention: Switch on heating system below + 5 °C ambient temperature. The type of heating cable has to be calculated: heat output per heating cable between 20 - 25 W/m. For longer heating distances the total length has to be devided into several heating sections. (2) Arrangeheating cable For short heating distances to feed with lower secondary voltage via transformer. 400V Heating capacity...

Open the catalog to page 17