video corpo

Compact Conductor Systems VKS10
28Pages

{{requestButtons}}

Catalog excerpts

Compact Conductor Systems VKS10 - 1

Compact Conductor System VKS10

Open the catalog to page 1
Compact Conductor Systems VKS10 - 3

VAHLE compact conductor system type VKS10 are compact and shock hazard protected safety conductor rails. They consist of a flatformed insulated housing with integrated copper conductors. These conductors are protected according to European standard EN 60529. They comply with accident and VDE regulations in the context of electrical, mechanical and fire safety and are protected to IP 21 standards. For the collectors is the contact protection only applies if the carbons are complete in the conductor. Conductor systems located within arm’s reach, and in which the collectors leave the conductor...

Open the catalog to page 3
Compact Conductor Systems VKS10 - 4

VKS10 Compact conductor system Isolating sections Application area: Indoor installation Conductor dead sections are electrical interrupts of the conductor. Under normal operating conditions a cross over with collectors to switch the voltage off or on is only allowed with low power ratings (control current). Conductor dead sections can be mounted at any position of the system. The plastic inserts are pushed into the copper profiles and ensure a smooth transfer of the collector brushes. The length of the isolating section has to consider the total length of the carbon brush and whether the...

Open the catalog to page 4
Compact Conductor Systems VKS10 - 5

fixpoint hanger sliding hanger line feed VLS end feed = length of conductor section (standard lenght: 1m, 2m, 3m, 4m, 5m, 6 m respectively short lenght) = support distance for straight runs: max. 1.2m in curves: max. 0.6 m = overhang (max. 350mm) = distance, to be allowed for conductor system expansion (min. 50mm) Max. hanger distance Conductor system VKS10 • in straight runs 1,2 m • in curves 0,6 m • horizontal 0,6 m Support profile VTP10 • on rack uprights • on support posts • horizontal arrangement • attached to the wall Arrangement 1 min. 180 (KESR) min. 250 (KST, KESL) line feed hanger...

Open the catalog to page 5
Compact Conductor Systems VKS10 - 6

Sections Standard lenghts: 6 m Cold stores: 4 m HS = with ground Attention: Joints to be ordered separately (see page 8). Complete types e.g. VKS10-6/60-2000HSA for 2 m. Order-No. 780 042 The 4-digit number (in bold) in the type indicates the length of the section in mm. (1) At 80% duty cycle (4) Consult factory in case of circuits incl. N conductors. • The last number of the order specifies the section length. (2) 2 conductors per phase (5) Not with UL-approval: Uul=600 V Please suffix the order number with 1, 2, 3, 4. (3) Powerail projecting length 34 mm at 20 °C ambient

Open the catalog to page 6
Compact Conductor Systems VKS10 - 8

Curved sections Copper cross section min. 25 mm2 Max. length of bend = 5,3 m Inside bend = conductors inside Outside bend = conductors outside (not shown) Bends are supplied with straight ends, each 250 mm long. (1) Smaller radius on request (2) In case of hall expansion joints please consider expansion sections (on request). (3) Conductor rails connected in parallel

Open the catalog to page 8
Compact Conductor Systems VKS10 - 9

Fixpoint hanger on C-rail consisting of hanger clamp and fixing screw and C-rail Fixing screw Sliding hanger on C-rail consisting of hanger clamp and C-rail Fixpoint hanger for support profile VTP 10 consisting of hanger and fixing screw Sliding hanger for support profile VTP 10 consisting of hanger clamp Fixing screw End cap Can be used right or left handed. Supplied loose as individual part with fixing screws. End feed (1) Terminal box supplied loose, only in conjunction with line feed VLS(2) (1) Cable glands 2 x ST-M 40 x 1,5 for 0 = 19-28 mm 1 x ST-M 20 x 1,5 fur 0 = 7-13 mm (2) Please...

Open the catalog to page 9
Compact Conductor Systems VKS10 - 10

Line feed VLS for direct connection of single core cables M6 terminal with special cable shoe for single core cables; 35 mm2 (up to cable 0 8.5 mm) for 140 A, 25 mm2 (up to cable 0 8.2 mm) for 100 A - 120 A, or feed bolts for 60 A conductor system 1 m section to be ordered separately right side

Open the catalog to page 10
Compact Conductor Systems VKS10 - 11

Line feed VNS with terminal box Cable gland: STR-M 63 x 1,5 fur 0 =28-45 STR-M 20 x 1,5 fur 0 = 5-13 Connection cable: to be supplied by customer Cable connection: Main current: M10 Control current: M5 1 m section to be ordered separately. Cable payout left, standard (1) For specification of the conductor profile refer to page 6 (2) Length of the conductor dead section (longer dead sections on request).

Open the catalog to page 11
Compact Conductor Systems VKS10 - 12

Auxiliary support and xing claw (Order.-No. 780 088) to be ordered seperately for current collector KSTU 30-63-14 max. speed v= 100 m/min. Tolerances: = ± 10 mm x y = ± 10 mm Conductor system VKS 10 to be ordered seperately Type see table below 1365 support prole Conductor section for funnel (all cross sections 25 mm2, lenght 1365 mm) Type (1) ransfer funnel only in combination with conductor section. T

Open the catalog to page 12
Compact Conductor Systems VKS10 - 13

Tangential entry funnel for collector KSTU 30-63 max. entry speed v = 100 m/min. Copper cross section min. 25 mm2 Tolerances: x = ± 10 mm y = + 8 mm, -7 mm (1) Length of the conductor dead section (longer dead sections on request)

Open the catalog to page 13
Compact Conductor Systems VKS10 - 14

Compact current collector KESR 32-55 for reverse run Distance between conductors: 14 mm Lift and swivel ± 15 mm Contact pressure: approx.: 7 N per carbon brush PE (ground) on No. 4, (other combinations possible) The ground collector always moves first when entering the conductor system.

Open the catalog to page 14
Compact Conductor Systems VKS10 - 15

torque setting: 1,7 Nm(1) (bolted connection) Compact current collector KESR 63S for reverse run with adapter plate and clamping block. Distance between conductors: 14 mm Lift and swivel ± 15 mm Contact pressure: approx.: 7 N per carbon brush PE (ground) on No. 4, (other combinations possible) The ground collector always moves first when entering the conductor system. Left hand version as shown Ground on No.4 (1) Max. cross section of connecting cable 16 mm2 (UL = 10 mm2)

Open the catalog to page 15
Compact Conductor Systems VKS10 - 16

Compact current collector KESL 32-63 for reverse run Distance between conductors: 14 mm Lift and swivel ± 30 mm Contact pressure approx.: 7 N per carbon brush PE (ground) on No. 4, (other combinations possible) The ground collector always moves first when entering the conductor system.

Open the catalog to page 16
Compact Conductor Systems VKS10 - 17

torque setting: 1,7 Nm(1) (bolted connection) Compact current collector KESL63 S for reverse run with adapter plate and clamping block. Distance between conductors: 14 mm Lift and swivel ± 30 mm Contact pressure: approx.: 7 N per carbon brush PE (ground) on No. 4, (other combinations possible) The ground collector always moves first when entering the conductor system. Left hand version as shown Ground on No.4 (1) Max. cross section of connecting cable 16 mm2 (UL = 10 mm2)

Open the catalog to page 17

All Paul Vahle GmbH & Co. KG catalogs and technical brochures

  1. BOK System

    4 Pages

Archived catalogs