COMPACT CONDUCTOR SYSTEMS ELECTRIFICATION SYSTEMS

Open the catalog to page 1
Compact Conductor System VKS10 - 2

POWERAIL ENCLOSED CONDUCTORS VKS 10 CONTENTS General Planning guide Application photos Technical data, standard sections Curved sections and jointing material Hangers End caps End feeds Line feeds Transfer funnels Tangential entry funnel, transfer guide and powerail isolating section Compact current collectors Single current collectors Connecting cables Accessories and spare parts for current collectors Support profile for high bay storage Support profile attachments Positioning systems Installation tools for VKS 10 Questionnaire(1) General VAHLE compact conductor system type VKS 10 are...

Open the catalog to page 2
Compact Conductor System VKS10 - 3

POWERAIL ENCLOSED CONDUCTORS VKS 10 VKS-10 Powerail Area of application: Indoor installation Sections: The insulated housing accommodates up to max. 10 conductors and provides reliable insulation. The standard length is 6 m, shorter lengths can be supplied. The ground conductor rail is identified with continuous yellow marking. The asymmetric design eliminates the possibility of reversing the phases during installation. One fixpoint hanger is required for each powerail section. Joints: The insulated housing sections are connected with joint caps, the conductors are joined with copper...

Open the catalog to page 3
Compact Conductor System VKS10 - 4

PLANNING GUIDE VKS 10 1. System diagram L L1 fixpoint hanger sliding hanger end feed L = length of powerail section (standard lenght: 1 m, 2 m, 3 m, 4 m, 5 m, 6 m respectively short lenght) L1 = distance for straight runs: max. 1.2 m in curves: max. 0.6 m L2 = overhang (max. 300 mm) L3 = distance, to be allowed for powerail expansion (min. 50 mm) 2. Symbols used in installation drawing Runway Powerail Fixpoint hanger Sliding hanger Line feed Section isolator Transfer funnel a) Powerail VKS 10 -in straight runs -in curves Horizontal b) Support profile VTP 10 -on rack uprights -on support...

Open the catalog to page 4
Compact Conductor System VKS10 - 6

m At 80% duty cycle P) Not with UL-approval; UUL= 600 V (2) 2 conductors per phase. . Supplement type designations, e.g. 2 m VKS 10-6/60 with PE (ground) (3) Powerail projecting length 34 mm at 20 °C ambient. ^VKS 10-6/60 - 2 HS Order-No. 780042. <4> Consult factory in case of circuits incl. N conductors. short |engths wi|, be produced 0ut of the next larger

Open the catalog to page 6
Compact Conductor System VKS10 - 7

STANDARD SECTIONS VKS 10 Right side Left side

Open the catalog to page 7
Compact Conductor System VKS10 - 8

CURVED SECTIONS AND JOINTS VKS 10 Curved sections vertical in accordance with your design drawings Copper cross section min. 25 mm2 Max. length of bend Hanger distance Max. angle Inside bend Outside bend = 5.3 m Ȃ 0.6 m = 180° = conductors inside = conductors outside (not shown) Inside bend R Outside bend R Bends are supplied with straight ends, each 250 mm long. R mm (2) Inside bend (as shown) Outside bend Conductor rails connected in parallel Smaller radius on request In case of hall expansion joints please consider expansion sections (on request)

Open the catalog to page 8
Compact Conductor System VKS10 - 9

FIXPOINT HANGERS, SLIDING HANGERS, END CAPS, END FEEDS VKS 10 Fixpoint hanger on C-rail Sliding hanger on C-rail consisting of hanger clamp and fixing screw and C-rail consisting of hanger clamp and C-rail Fixing screw Sliding hanger for support profile VTP 10 consisting of hanger clamp Fixpoint hanger for support profile VTP 10 consisting of hanger and fixing screw 56,5 Fixing screw Support profile Can be used right or left handed. Supplied loose as individual part with fixing screws. Terminal box supplied loose, only in conjunction with line feed VLS(2) Cable glands, 2 x ST-M 40 x 1.5 for...

Open the catalog to page 9
Compact Conductor System VKS10 - 10

LINE FEED VKS 10 Line feed VLS for direct connection of single core cables right side left side VLS 10- 5/140 VLS 10- 6/ 60 1 m section to be ordered separately. M6 terminal with special cable shoe for single core cables; 35 mm2 (up to cable Ø 8.5 mm) for 140 A, 25 mm2 (up to cable Ø 8.2 mm) for 100 A - 120 A, or feed bolts for 60 A powerail Opening for cable outlet Cable outlet double-sided Line feed VNS with terminal box Cable gland: STR - M 63 x 1,5 for Ø = 28-45 STR - M 20 x 1,5 for Ø = 5-13 Connection cable to be supplied by customer Cable connection: Main current: M10 Control current:...

Open the catalog to page 10
Compact Conductor System VKS10 - 11

TRANSFER FUNNELS VKS 10 Transfer funnel (1) for current collector KESL 32-63/14 max. speed v= 100 m/min. Conductor rails for funnels (all cross sections 25 mm2, length 1365 mm) Type No. of conductors 4 No. of conductors 5 No. of conductors 6 No. of conductors 7 No. of conductors 8 No. of conductors 9 No. of conductors 10 775 Auxiliary support and fixing claw to be ordered seperately Powerail VKS 10 to be ordered seperately Type see table above 1365 Support profile Transfer funnel only in combination with powerail section. Higher speeds on request.

Open the catalog to page 11
Compact Conductor System VKS10 - 12

TANGENTIAL ENTRY FUNNEL, POWERAIL SECTION ISOLATION VKS 10 Tangential entry funnel for collector KSTU 30 - 55 max. entry speed v = 100 m/min. Copper cross section min. 25 mm2 92 47 For cross travel and terminal lines max. height- and lateral off-set: ± 2 mm max. air gap between the transfer guides: 5 mm Powerail isolating section(1) The position of the isolating sections are to be identified in the order. VSTS 1/10-60 M VSTS 1/ 100 M VSTS 1/ 120 M VSTS 1/ 140 M M = factory assembled; L = supplied loose For specification of the powerail profile see page 6 Length of the conductor dead section...

Open the catalog to page 12
Compact Conductor System VKS10 - 13

CURRENT COLLECTOR VKS 10 Compact current collector KESR 32/55 for reverse run Distance between conductors: max. current flat plug bolted connection Flat plug 6,3 x 0,8 for FLA or bolted connection Lift and swivel ± 15 mm Contact pressure: approx. 3.5 N per carbon brush PE (ground) on No. 4, other combinations possible The ground collector always moves first when entering the powerail. KESR-F for connecting cables with flat plug see table 1 page 16 Type KESR 32-55 F 4-14 HS KESR 32-55 F 5-14 HS KESR 32-55 F 6-14 HS KESR 32-55 F 7-14 HS KESR 32-55 F 8-14 HS KESR 32-55 F 9-14 HS KESR 32-55 F...

Open the catalog to page 13
Compact Conductor System VKS10 - 14

CURRENT COLLECTOR VKS 10 Compact current collector KESL 32-63 for reverse run Distance between conductors: flat plug bolted connection Lift and swivel ± 30 mm Contact pressure: approx. 7 N per carbon brush PE (ground) on no. 4, other combinations possible The ground collector always moves first when entering the powerail. Flat plug 6,3 x 0,8 for FLA or bolted connection KESL-F for connecting cables with flat plug see table 1 page 16 Type KESL 32-55 F 4-14 HS KESL 32-55 F 5-14 HS KESL 32-55 F 6-14 HS KESL 32-55 F 7-14 HS KESL 32-55 F 8-14 HS KESL 32-55 F 9-14 HS KESL 32-55 F 10-14 HS 4-pole...

Open the catalog to page 14