Catalog excerpts
5,500kN Injection Molding Machine Circle Core magnetic clamp (Slim model) & Valve stand
Open the catalog to page 1.BHDMBNQUIBUDPOTVNFTMFTTFOFSHZ 'PSB L/NPMEJOHNBDIJOFXJUIB.BH$MBNQ FMFDUSJDJUZDPTUTZFOQFSNPMEDIBOHF &MFDUSJDJUZJTPOMZSFRVJSFEXIFODMBNQJOHPSVODMBNQJOH
Open the catalog to page 54VQFSTUSPOH/FPEJVNNBHOFUTTFDVSFMZDMBNQNPMET 5IFTUBOEBSENPMEXFJHIUGPSB L/NPMEJOHNBDIJOFJTUPOT BOEUIFDMBNQJOHGPSDFSFRVJSFEGPSB.BH$MBNQJTL/ UPOT
Open the catalog to page 7IOTUBOUMZDMBNQTNPMET TFDPOETUPDMBNQGPSB L/NPMEJOHNBDIJOF TFDPOETUPDMBNQGPSB L/ QFSQMBUF
Open the catalog to page 11.VMUJ.BH$MBNQ JEFBMDMBNQJOHEFWJDFGPSNVMUJQMF NPMEJOHNBDIJOFTBUNJOJNBMDPTU
Open the catalog to page 13Temperature of mold plate The Mag clamp is designed for reliabilty and economic eciency. It is more ecomomical than the Square core mag clamp Standard model Clamping force Moving platen Slim model Standard model Clamping force Fixed platen Moving platen Slim model This model is about 10% more economical than the standard type
Open the catalog to page 16Temperature of mold plate Economical model that allows one controller to operate multiple Mag Clamps Clamping force 3,500kN IMM Sharing the same controller Standard model Slim model This model is about 10% more economical than the standard type
Open the catalog to page 17Temperature of mold plate Select a Square Core Mag Clamp for applications with high temperatures above 120℃ Clamping force Fixed platen Fixed platen Moving platen Moving platen See page → 44 for details ※ 52mm plate thickness for machines that are 4,500kN or la
Open the catalog to page 20Temperature of mold plate A 35mm thick plate is available for machines up to 1,500kN Clamping force Fixed platen Fixed platen Moving platen Moving platen
Open the catalog to page 21Temperature of mold plate Square core models are suitable for vertical molding machines in view of Mag clamp functionality.
Open the catalog to page 22of 4RVBSF$PSF.BH$MBNQGPSB .VMUJ$PMPS I.. Temperature mold plate 80150180℃ Square core models are suitable for 2-color molding machines in view of Mag clamp functionality. Fixed platen Fixed platen Moving platen Moving platen
Open the catalog to page 23"VUPNBUFNPMEDMBNQJOHPQFSBUJPOT Mounting and demounting molds with eight bolts using wrenches is hard work. Working underneath the molds is dangerous. The Mag clamp can clamp and unclamp molds safely and easily, instantaneously reducing production times and heavy workloads, resulting in increased productivity and a more comfortable work environment. Taking time to fasten/loosen the screw Dicult working posture Mag clamp clamps and unclamps molds in 0.5 to 4.5 seconds. Operation panel Simply push the button
Open the catalog to page 24"VUPNBUFEDMBNQJOHSFHBSEMFTTPGNPMETJ[F No standardizing the mold size and thickness of mold plate is necessary. Use the machine platen area to the maxium No interferences with the wire or hose Extra space is not necessary to mount conventional clamps on the machine platen and molds can be designed without any dimensional constraints. Extra space is required to mount manual or hydraulic clamps on the platen, and core cylinders, electrical connectors, couplers and hoses can create interferences.
Open the catalog to page 25;FSPFOFSHZDMBNQJOHJTBDDPNQMJTIFE XJUITVQFSTUSPOHOFPEZNJVNNBHOFUT No electric power is required when clamping the mold, and an air compressor and hydraulic pump motor are not necessary. Structure Clamp Eective height of magnetic ux : Approx 20mm Neodymium magnet Lines of magnetic ux S N Electromagnetic coil Polarity of alnico magnet is inverted. Alnico magnet Polarity is inverted by electromagnetic coil Clamp plate ① Electromagnetic coil is energized for 0.5 sec. ① Electromagnetic coil is energized for 0.5 sec. ② Polarity of alnico magnet is inverted. ② Polarity of alnico magnet is inverted....
Open the catalog to page 26When the mold is displaced or the mold floats above the clamp plate due to a rare mis-set ejector pin, mis-set nozzle touch, or guide pin getting stuck, the mold dislacement detection system detects the abnormality and stops the machine immediately. Displacement or lifting of the mold can be detected by the electromagnetic coils that are built in the magnet core located near the center of clamp plate. When the mold moves, these electromagnetic coils detect an induction current signal. Normal clamping status When the mold moves or lifts The mold is secured close to the magnet core. Clamp...
Open the catalog to page 27Circle Core magnetic clamp
Open the catalog to page 28Standard model Fixed platen Moving platen Slim model Fixed platen Circle Core magnetic clamp Moving platen The model about 10% more economical than the standard type
Open the catalog to page 29Fixed platen side Moving platen side Locate ring Clamp plate Circle Core magnetic clamp Mold fall protection hook (option) Mounting bolt Block for mold fall protection Laterally long mold Specifications Model Plate shape Standard model Clamping force Operating temperature 20 (mold plate material SS400) Plate thickness Power voltage Mold displacement detection system (Fixed and moving platen) Plate mounting method Bolting with the tap holes of machine platens ● Operating temperature indicates the temperature on the surface of the clamp plate ● Additional tap holes are necessary in the center...
Open the catalog to page 30Clamp plate Weight kg Voltage Min. mold capacity size Fixed platen Moving side platen side Eye bolt on mold Model Max. Allowable load per hook Circle Core magnetic clamp Mold fall protection hook(optional) ● Reference value ● Capacity when 200/220VAC power voltage. Ask Pascal for 380, 440 and 480VAC. ● Reference value under normal production conditions, not guaranteed. ● The size of eye bolt on the mold is determined according to th e size of the hook. Make sure that the allowable load of the eye bolt is greater than the mold weight. ● The number of eye bolts on mold side indicates o
Open the catalog to page 31$JSDMF$PSFNBHOFUJDDMBNQ4MJNNPEFMClamping force 750 - 6,500 kN Fixed platen side Moving platen side Locate ring Clamp plate MFA Circle Core magnetic clamp Mold fall protection hook (option) Mounting bolt Mold that ts between the tie bar Block for mold fall protection Specifications Model Plate shape Slim model Clamping force Operating temperature 20 (mold plate material SS400) Plate thickness Power voltage Mold displacement detection system (Fixed and moving platen) Plate mounting method Bolting with the tap holes of machine platens ● Operating temperature indicates the temperature on the...
Open the catalog to page 32All Pascal Engineering Inc. catalogs and technical brochures
-
Pascal auto coupler
60 Pages
-
Pascal mold change system
68 Pages
-
Mold clamping system
136 Pages
-
Press machine system
48 Pages
-
Stamping die clamping system
254 Pages
-
Pascal N2 gas springs
28 Pages
-
mini Gas springs
40 Pages
-
N2 gas springs
86 Pages
-
Pascal Products Introductions
76 Pages
-
Expansion clamp
142 Pages
-
air Work clamping system
130 Pages
-
35MPa Work clamping system
177 Pages
-
Pal system
106 Pages
-
7MPa Work clamping system
256 Pages