Group: Spectris

Catalog excerpts

HPD III High Pressure Diffuser Aerosol Monitoring Accessory BENEFITS • Measures gases from 5 to 100 psi (range dependent on model) • No external flow meters needed • Low contamination, < 5% of ISO Class 5 cleanliness • Economical monitoring of pressurized gases with atmospheric pressure particle counters • Can be used with Clean Dry Air (CDA), argon, nitrogen, carbon dioxide or other non-toxic inert gases • Seven different versions for 0.1 CFM, 1.0 CFM, 50 LPM, and 100 LPM flow rates F E AT U R E S High Pressure Diffusers (HPDs) have been developed to address the challenge of sampling pressures of 5 – 100 psi, and the possible damage that can result from connecting pressurized air or gas to a particle counter. HPDs reduce the pressure of the gas to near atmospheric pressure by allowing some of the gas to diffuse out of the system, allowing the particle counter’s flow-metering system to function as designed. The HPD III Aerosol Monitoring Accessory is compatible with nontoxic, non-flammable gases such as Clean Dry Air (CDA), argon, nitrogen and carbon dioxide. The higher pressure gases are reduced to a level acceptable to particle counters designed to operate at atmospheric pressure. • No moving parts to wear • Connects via male 4-VCR fitting • Exhaust filter prevents possible room contamination • Mounting clamps supplied • Stainless steel construction A P P L I C AT I O N S • Nano-ID® NPC10 nanoparticle counter • Lasair® III particle counter models 310B, 310C, 350C, and 5100 • Airnet® II particle sensor models 301, 501, 510, and 510XR • IsoAir® 310P particle counter
Open the catalog to page 1
HPD III High Pressure Diffuser Aerosol Monitoring Accessory High Pressure 20 – 100 psi for 0.1 CFM, 1.0 CFM, 50 LPM flow rates 60 – 100 psi for 100 LPM flow rate Low Pressure 5 – 25 psi for 1.0 CFM and 50 LPM flow rates 20 – 60 psi for 100 LPM flow rate Flow rate Particle size range Temperature range Enclosure: 316L stainless steel body, exhaust filter Gaskets: 316 stainless steel, Buna-N O-rings Dry, inert, non-toxic, non-flammable gases (CDA, nitrogen, argon, carbon dioxide) NOTE : For carbon dioxide sampling, contact Particle Measuring Systems. Inlet fitting Male 4-VCR fitting, #4 size,...
Open the catalog to page 2All Particle Measuring Systems catalogs and technical brochures
-
Pharmabilities
9 Pages
-
EL Capabilities
15 Pages
-
BioCapt SU
8 Pages
-
Aerosol Manifold II
2 Pages
-
Pharmabilities Brochure
9 Pages
-
UltraChem 40
2 Pages
-
MiniCapt Mobile
2 Pages
-
Facility Pro
4 Pages
-
AirNet II
2 Pages
-
Ultra DI® 20
2 Pages
Archived catalogs
-
Lasair III Particle Counter
2 Pages