1. Catalogs
  2. Particle Measuring Systems
  3. APSS-2000 Parenteral Particle Counter
video corpo

APSS-2000 Parenteral Particle Counter

APSS-2000 Parenteral Particle Counter

APSS-2000 Parenteral Particle Counter

Product catalog summary
Overview
The APSS-2000 is an Automated Parenteral Sampling System designed to size and count suspended particulate matter in various liquids, complying with USP, EP, and JP standards. It includes an SLS-2000 syringe sampler, a LiQuilaz® II E Series spectrometer, and SamplerSight Pharma software, ensuring adherence to 21 CFR Part 11 regulations.

Benefits
  • Defect Reduction: Ensures 100% sample volume accuracy with precise volume control, repeatable results, and comprehensive validation documentation.
  • User-Friendly: Features recipes for consistent sample processing, automated calibration, quality control alarms, and automated data backup.
  • Comprehensive System: Offers easy navigation, security features, customizable reports, and electronic approvals.

Features
  • Particle size measurement from 1.5 to 125 µm with 15 selectable channels.
  • Sample volumes range from 0.4 ml to 1 liter.
  • Includes adapters for SVI and IV bag testing and automated sensor calibration.

Applications
  • Pharmaceutical parenteral monitoring.
  • Medical device cleanliness testing.
  • Laboratory water sampling and filter efficiency testing.

Specifications
  • Liquid Sensor: LiQuilaz® II E-20P and E-15P with size ranges of 2-125 µm and 1.5-125 µm respectively, 15 size channels, and a flow rate of 20 ml/min.
  • Liquid Sampler: SLS-2000 with syringe sizes of 1, 5, 10, and 25 ml, vacuum sampling mode, and minimum sample volume of 0.4 ml.
  • Software: SamplerSight Pharma compatible with Windows® 10.

Contact Information
Headquarters: Boulder, Colorado, USA. Global offices in Austria, Benelux, Brazil, China, France, Germany, Italy, Japan, Korea, Mexico, Nordic, Puerto Rico, Singapore, Switzerland, and Taiwan.
See more

Catalog excerpts

APSS-2000 Parenteral Particle Counter-1

Automated Parenteral Sampling System Sizes and counts suspended particulate matter in a wide range of liquids to meet regulation standards BENEFITS The APSS-2000 syringe sampling system sizes and counts suspended particulate matter in a wide range of liquids and meets or exceeds all current USP, EP, and JP requirements. Recipe functions allow the APSS-2000 to adapt to future regulatory changes. The APSS-2000 system consists of an SLS-2000 syringe sampler, a LiQuilaz® II E Series light obscuration spectrometer, and SamplerSight Pharma software, allowing reports to meet 21 CFR Part 11 regulations. Defect Reduction • 100% sample volume for greater accuracy • A precise sample volume within 0.4 ml is achieved with the syringe sampler, producing repeatable results • SamplerSight Pharma software comes with a Validation Information Notebook, providing comprehensive software development documentation and full IQ, OQ, and PQ protocols • SamplerSight Pharma complies with FDA 21 CFR 11 User-Friendly • Reduce operator error and ensure process accuracy with recipes for repeat sample processing to USP, EP, or JP standards • Automated particle counter calibration wizard for full calibration or routine verification • Alarm levels for pass/fail criteria ensure quality control • Automated backup scheduling ensures enhanced data integrity Comprehensive System • Easy-to-use pull-down menus • Active Directory security password maintains system integrity • Particle measurements are reported per ml or per container values • Small sample volume minimizes waste of expensive product • Various custom report formats are available • Electronic report approval Particle size capability from 1.5 to 125 µm Fifteen user-selectable sizing channels Meets and exceeds all USP, EP and JP requirements Sample volumes from 0.4 ml to 1 liter Adapters for SVI and IV bag testing Automated sensor calibration Plug and play ultrasonic bath and magnetic stirrer options available A P P L I C AT I O N S • Pharmaceutical parenteral monitoring to USP, EP, JP and FDA • • • • standards Parts/medical device cleanliness testing Laboratory water sampling Water for Injection (WFI) and Pu

 Open the catalog to page 1
APSS-2000 Parenteral Particle Counter-2

Automated Parenteral Sampling System Liquid Sensor Size Range Size Channels Flow Rates Volume Sampled Maximum Concentration Sample Temperature Zero-count Level Capillary Size Maximum Pressure Maximum Sample Viscosity Laser Source Laser diode Wetted Surface Materials 1 Fused Silica, Black Quartz, Teflon, Kel-F®, Kalrez® Greater than 90% accuracy (less than 10% coincidence loss) at maximum recommended concentration. Liquid Sampler Syringe Size Sampling Mode Minimum Sample Volume Wetted Surface Materials Glass, Teflon 17.1 x 9 x 15 in (43.4 x 22.9 x 38.1 cm) Including particle counter Weight (Particle...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.