Introduction
The document introduces the Parr Instrument Company's series of Oxygen Combustion Calorimeters, emphasizing their historical significance and technological advancements. Founded by Professor S.W. Parr in 1899, the company continues to innovate in calorimetry, offering a range of calorimeters for various laboratory needs.
Calorimeter Models Overview
The document provides an overview of several calorimeter models:
  • Model 6400 Automatic Isoperibol Calorimeter: High throughput with minimal operator time, allowing simultaneous operation of multiple units.
  • Model 6200 Isoperibol Calorimeter: Known for precision and accuracy, suitable for quality control and research.
  • Model 6100 Compensated Jacket Calorimeter: Ideal for testing alternative fuels with real-time corrected methods.
  • Model 6050 Compensated Jacket Calorimeter: Compact and automated, controlled via personal computer.
  • Model 1341 Plain Jacket Calorimeter: Cost-effective for basic testing and educational purposes.
  • Model 6725 Semimicro Calorimeter: Suitable for small sample combustion, often used in marine biology.
  • Model 6755 Solution Calorimeter: Measures enthalpy changes in solutions, used in educational settings.
  • Model 6790 Detonation Calorimeter: Measures heat of detonation for explosives research.
Quality Assurance and Standards
The company adheres to a robust Quality Assurance Program, certified under ISO 9001-2015, CSA, and CE standards. Their calorimeters comply with various international test methods, ensuring reliability and accuracy in calorific measurements.
Calorimeter Selection and Design
Selection depends on workload, precision requirements, standard methods, and budget. The document details different jacket designs and their impact on performance, including isoperibol and compensated jacket methods.
Specifications and Features
The document provides detailed specifications for various models, highlighting features like automatic oxygen filling, precision classifications, and specific applications. For example, the 6400 model supports up to four simultaneous operations with minimal operator time.
Applications and Recommendations
Removable bomb calorimeters are recommended for applications needing control over the test process or handling corrosive residues. The choice of bomb style depends on sample size and material requirements.
Procedures and Usage
The 6755 Solution Calorimeter is designed for measuring heats of reactions, mixing, solution, dilution, and wetting. It operates at ambient temperature and atmospheric pressure, suitable for both liquid-liquid and liquid-solid systems.
Detonation Calorimeter
The Parr 6790 Detonation Calorimeter is designed for measuring the heat of detonation of highly reactive materials, highlighting the challenges and differences in energy release compared to conventional combustion calorimetry.
Conclusion
Parr Instrument Company offers a diverse range of calorimeters, each designed to meet specific laboratory needs, from high precision research to educational purposes. Their commitment to quality and innovation ensures that their products remain at the forefront of calorimetric technology.
See more

Catalog excerpts

Series 6000 Oxygen Bomb Calorimeters-1

Parr Instrument Company Series 6000 Oxygen Combustion Calorimeters 6000 Designing and Building High Precision Combustion Calorimeters for 120 Years

 Open the catalog to page 1
Series 6000 Oxygen Bomb Calorimeters-2

Founded in 1899 by University of Illinois Professor S.W. Parr, Parr Instrument Company has consistently strived to provide for its customers the very best in product, service and support. Parr Instrument Company e are pleased to have this opportunity to tell you about our Oxygen Combustion Calorimeters. In 1899, Professor S.W. Parr introduced his first calorimeter intended for routine fuel testing. We believe we are continuing his tradition of applying the latest in technology to meet the real needs of today’s research and fuel testing laboratories. In these Calorimeters we have combined our...

 Open the catalog to page 2
Series 6000 Oxygen Bomb Calorimeters-3

Models Overview Model 6400 Automatic Isoperibol Calorimeter This calorimeter allows labs to achieve maximum productivity. Designed for laboratories that require high throughput, the 6400 is highly automated and requires only about one minute of operator time per test, freeing up the Lab Technician to run up to four 6400 Calorimeters simultaneously. The 6400 delivers excellent precision and accuracy. Table of Contents Table of Contents Quality Assurance . . . . . . . . . . . 4 Standard Test Methods . . . . . . . 4 Introduction . . . . . . . . . . . . . . . . . 5 Calorimeter Selection . . . . ....

 Open the catalog to page 3
Series 6000 Oxygen Bomb Calorimeters-4

Quality Assurance Standard Test Methods Compliance ISO 9001-2015 Certification Parr Instrument Company’s overall Quality Assurance System has been certified to be in compliance with ISO 9001-2015 by TÜV. ISO 9001-2015 covers the overall quality assurance and management compliance aspects of Parr’s activities as opposed to the certification of an individual product. ASTM Standard Test Methods - ASTM D240, “Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter” arr Instrument Company operates under a Quality Assurance Program. This program ensures that all...

 Open the catalog to page 4
Series 6000 Oxygen Bomb Calorimeters-5

Introduction: Bomb Calorimetry Calorimeter Selection omb calorimetry is a fundamental test of great significance to anyone interested in calorific measurements. The following list includes possible applications: - Coal and coke, all varieties and types Fuel oil, both heavy and light varieties Gasoline, all motor fuel and aviation types jet fuels, all varieties Combustible wastes and refuse disposal Foodstuffs and supplements for human nutrition Forage crops and supplements for animal nutrition Building materials Explosives and heat powders Rocket fuels and related propellants Thermodynamic studies...

 Open the catalog to page 5
Series 6000 Oxygen Bomb Calorimeters-6

Jacket Designs Time arr Series 6000 Oxygen Bomb Calorimeters described in this brochure feature a high degree of automation with touch screen operation, Linux operating system and fifth generation microprocessor control. Isoperibol Calorimetry An isoperibol calorimeter is one where the surrounding jacket is maintained at a constant temperature while Sample the temperature of the bomb Fired and bucket rise as Measured heat is released by the combustion. The Model Jacket 6400 and 6200 Calorimeters are true isoperibol calorimeters. In these implementations, a controlled temperature jacket,Calorimeter...

 Open the catalog to page 6
Series 6000 Oxygen Bomb Calorimeters-7

Parr Removable Bomb and Bucket Technology emovable bomb calorimeters are the more traditional design most users will recognize. In this design the oxygen bomb and bucket are removed from the calorimeter for loading the sample and filling the bucket with the carefully measured amount of water which absorbs the energy released in the combustion. The choice of bomb style may affect the calorimeter chosen. Bomb choice is dictated by sample size and alloy of construction. These bombs range in sample size from 500 to 12,000 calories per charge, and are offered in different alloys and designs for a...

 Open the catalog to page 7
Series 6000 Oxygen Bomb Calorimeters-8

Parr Fixed Bomb and Bucket Technology n the fixed bomb and bucket design used in the 6400 Automatic Isoperibol Calorimeter, the bomb and bucket are not removed from the calorimeter during routine operations. This design concept has made it possible to offer unique levels of automation for the entire calorimetric determination, not just the data collection and reporting steps. The result of this automation will save approximately five minutes of operator time per test when compared to any removable bomb calorimeter. Oxygen Charging and Release The fixed bomb and bucket design allow the oxygen...

 Open the catalog to page 8
Series 6000 Oxygen Bomb Calorimeters-9

Parr Calorimeter Selection Guide 6400 Automatic Isoperibol Calorimeter Type Operator Time per Test Precision Classification Bomb Type and Bucket Fixed Bomb and Bucket Design Removeable Bomb and Bucket Design Removeable Bomb and Bucket Design Removeable Bomb and Bucket Design Removeable Bomb and Bucket Design Removeable Bomb Dewar Flask Bucket Filling Oxygen Filling Bomb Washing Printer Connection Balance Connection Network Connection Temperature Resolution Page Number arr Instrument Company is committed to a process for continually upgrading our line of oxygen bomb calorimeters and their accessories....

 Open the catalog to page 9
Series 6000 Oxygen Bomb Calorimeters-10

6400 Automatic Isoperibol Calorimeter SPECIFICATIONS Model Number: 6–7 Operator Time Per Test: 1 Minute Precision Classification: 0.1% Class Jacket Type: Isoperibol, Water Jacket Oxygen Fill: Automatic Bucket Fill: Automatic Bomb Wash: Automatic Bomb Model Options: TCP/IP via Ethernet Dimensions (cm): 42w x 46d x 51h 6400 Automatic Isoperibol Calorimeter he 6400 Automatic Isoperibol Calorimeter represents the next evolutionary step in the Parr automated calorimeters. Inclusive and compact, the instrument incorporates a closed loop cooling subsystem into the calorimeter. This subsystem uses a...

 Open the catalog to page 10
Series 6000 Oxygen Bomb Calorimeters-11

1138 Oxygen Combustion Bomb Expanded System The 6420 Expanded System is a convenient way to order all of the components necessary for a complete system. The system includes the following parts: - Extra A1450DD Bomb Head Assembly 6400 Automatic Isoperibol Calorimeter open 6400 Automatic Isoperibol Calorimeter Ordering Guide Model No. 6400 Calorimeter with 1138 Oxygen Bomb of Alloy 20 6400 Calorimeter with 1138 Oxygen Bomb of Alloy G30 6420 Expanded System with 1138 Oxygen Bomb of Alloy 20 6420 Expanded System with 1138 Oxygen Bomb of Alloy G30 Parr Instrument Company

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.