Purpose: The PCS direct acting solenoid valves are designed for global applications, constructed from widely accepted materials, and available in carbon or stainless steel. They offer threaded or welded end connections and standard coil options for global use.
Product Features: Suitable for various refrigerants, available in plated steel or stainless steel housing, replaceable seat for easy service, interchangeable coil with other P-Series offerings, and available with Neoprene or HNBR O-rings.
Technical Data: Liquid temperature range for Neoprene is -60°C to 120°C, and for HNBR is -46°C to 120°C. Ambient temperature range is -60°C to 70°C. Maximum Rated Pressure (MRP) is 28 bar, with burst pressure over 5 times MRP. Coil classification includes IP65 and IP67 ratings.
Function and Design: The PCS is a direct acting normally closed solenoid valve, ideal for oil or liquid feed applications. It operates without pressure drop, opening when the coil is energized.
Installation: Valves should be installed in accessible locations, protected from damage, and insulated properly. Disassembly is required before welding to protect internal components.
Maintenance and Service: Periodic cleaning or replacement of components may be necessary. The system should be safely conditioned before maintenance. Disassembly involves removing the coil and operator, with care taken to avoid damage.
Electrical: The solenoid coil is designed for long life and powerful opening force, with IP67 and IP65 ratings. Coils are available for various voltages and frequencies, and must be connected to matching electrical lines.
Dimensional Information: Detailed dimensions and connection types are provided for various port sizes and connection methods.
Parts Kit Reference: Lists service parts and kits available for maintenance and repair.
Safe Operation: Personnel must be qualified and familiar with the system and valves. Precautions are necessary to avoid damage from liquid expansion in cold refrigerant lines.
Installation and Safety Procedures: When working on sections involving gaskets, pipes, or valves, ensure all hand valves isolating these sections are marked to prevent accidental closing. These valves should not be closed until the liquid is removed. Check valves should not be installed upstream of solenoid valves or regulators with electric shut-off. Hand valves upstream of solenoid valves or downstream of check valves should remain open until the liquid is removed. Relief devices should be installed in sections where liquid expansion might occur. Avoid piping or control setups that could cause thermal or pressure shock. Before opening or removing any valve, strainer, or device, ensure all refrigerant is removed from the section to protect people and products. Flanges with ODS connections are unsuitable for ammonia service.
Warranty Information: Refrigerating Specialties products are warranted against defects in workmanship and materials for one year from the shipment date. This warranty is valid only if products are properly installed, assembled, maintained, and operated as specified in Refrigerating Specialties Catalogs or Bulletins for normal refrigeration applications, unless otherwise approved in writing. Defective products returned with prepaid transportation charges and found defective upon inspection will be repaired or replaced free of charge. The warranty does not cover products altered, repaired in the field, damaged in transit, or subjected to accidents, misuse, or abuse. Products disabled by dirt or foreign substances are not considered defective. This express warranty is the only applicable warranty and replaces all other warranties, including any implied warranties of merchantability or fitness for a particular purpose. Refrigerating Specialties is not responsible for any consequential damages. No other person is authorized to provide warranties or assume liability on behalf of Refrigerating Specialties.
See more

Catalog excerpts

Parker Compact Solenoid-1

Parker Compact Solenoid Product Bulletin 30-80 A Type: PCS Purpose: The PCS direct acting solenoid valves are designed to work in a variety of applications around the world. The PCS is constructed from globally accepted materials and is available in carbon or stainless steel versions. This valve is also offered with either a threaded or welded end connection to allow for use in a variety of applications. The standard coil offering allows the PCS to be used anywhere in the world simply by specifying the needed voltage and frequency. Contact Information: Product Features: Parker Hannifin Corporation Refrigerating Specialties Division 2445 South 25th Avenue Broadview, IL 60155-3891 phone (708) 681-6300 fax (708) 681-6306 www.parker.com/refspec • Suitable for ammonia, CO2, R-22, R-134a, R-404a, R-410a, R-507 and other common refrigerants • Available as a plated steel or stainless steel housing to increase product lifecycles • Replaceable seat ensures easy service and long life • Coil interchangeable with other P-Series offerings • Coil options to meet various applications • Available with Neoprene or HNB

 Open the catalog to page 1
Parker Compact Solenoid-2

Table of Contents Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Technical Data Liquid Temp. Range Neoprene . . . . . -60°C to 120°C (-76°F to 248°F) Maximum Rated Pressure (MRP). . . . . . . . . . . . . . . . 28 bar (400 psig) Liquid Temp. Range HNBR . . . . . . . . -46°C to 120°C (-51°F to 248°F) Ambient Temperature Range . . . . . . . -60°C to 70°C (-76°F to 158°F) Coil Classification. . . . . . . . IP65(DIN) / IP67 (Leaded); NEMA 4; CE Connection inch Flow Coefficient Function and Design The PCS is a direct acting normally closed...

 Open the catalog to page 2
Parker Compact Solenoid-3

Installation Remove the solenoid tube and operator. Care should be taken as the operator is spring loaded into the solenoid tube and the two components will come apart. All valves are packed for a maximum protection. Unpack carefully. Check the carton to make sure all items are unpacked. Save the enclosed instruction for the installer and eventual user. Do not remove the protective coverings from the inlet and outlet of the valve until the valve is ready to be installed. Protect the inside of the valve from dirt and chips before and during installation. The valve should be installed in a location...

 Open the catalog to page 3
Parker Compact Solenoid-4

Bulletin 30-80 A Process Connections: The preferred mounting method for the PCS series valves is in the upright horizontal position. The valve must be installed with the arrow pointing in the direction of flow for the valve to function properly. Prior to welding protect the inside of the valve body from welding debris and dirt. Socket welding, where allowed, is the preferred connection. This connection helps to reduce the amount of welding debris in the piping system. Remove welding debris and any dirt from the pipes and valve body before reassembling the valve. In the event the valve is left...

 Open the catalog to page 4
Parker Compact Solenoid-5

Electrical The solenoid coil must be connected to electrical lines with Volts and Hertz same as stamped on coil. The supply circuits must be properly sized to give adequate voltage at the coil leads even when other electrical equipment is operating. The coil is designed to operate with line voltage from 85% to 110% of rated coil voltage. Operating with a line voltage above or below these limits may result in coil burn‑out. Also, operating with line voltage below the limit will definitely result in lowering the valve’s maximum opening pressure differential. Power consumption during nor al m operation...

 Open the catalog to page 5
Parker Compact Solenoid-6

Port Size Thread Type 1/4" National Pipe Thread Female Thread Type 3/8" National Pipe Thread Female 1/4" British Standard Pipe Taper Female 3/8" British Standard Pipe Taper Female 3/8" National Pipe Thread Female 3/8" British Standard Pipe Taper Female Socket Weld (SW) ANSI Port Size Nameplate Information Port Size Name Plate Image Name Plate 1. Valve Model Number (Smart Part Number) 2. Serial Number (S/N) 3. Connection Type and Size 4. Temperature Range 5. Year of Manufacture

 Open the catalog to page 6
Parker Compact Solenoid-7

Parts Kit Reference PCS Service Parts List Item Tube Assembly, Solenoid O-Ring, Tube (Neoprene) Seat, Solenoid Pilot Tool, Tube Assembly Tube Kit (Neoprene) 5 ⁄32” Orifice 1 ⁄8” Orifice Tube Assembly, Solenoid O-Ring, Tube (HNBR) Seat, Solenoid Pilot Tool, Tube Assembly Tube Kit (HNBR) 5 ⁄32” Orifice 1 ⁄8” Orifice Nut, Coil Spring Washer, Coil Coil Tool, Tube Assembly Consult Factory 1 Encapsulated coils are available in a variety of styles and voltages. Contact factory for coil options and part number.

 Open the catalog to page 7
Parker Compact Solenoid-8

Safe Operation (See Bulletin RSBCV) People doing any work on a refrigeration system must be qualified and completely familiar with the system and the Refrigerating Specialties Division valves involved, or all other precautions will be meaningless. This includes reading and understanding pertinent Refrigerating Specialties Division Product Bulletins and Safety Bulletin RSB prior to installation or servicing work. Where cold refrigerant liquid lines are used, it is necessary that certain precautions be taken to avoid damage which could result from liquid expansion. Temperature increase in a piping...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.