Catalog excerpts
© 2013 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies. Parker Hannifin Corporation Velcon Filtration Division 1210 Garden of the Gods Road Colorado Springs, CO 80907 USA tel +1 719 531 5855 www.velcon.com
Open the catalog to page 2aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Parker Velcon ENGINEERING YOUR SUCCESS.
Open the catalog to page 3The Velcon Filtration Division of Parker Hannifin manufactures a wide range of filtration and separation solutions and fuel condition monitoring products for use in assuring clean dry aviation fuel. Velcon’s product range includes micronic filters, fiberglass coalescers, separators, water absorbent cartridges, and clay canisters designed to meet required industry standards. This includes a complete line of cartridges qualified to the latest editions of EI specifications (EI 1581, EI 1583 & EI 1590). Velcon’s research, testing and product development team continues to seek solutions to many...
Open the catalog to page 4pressure of filter monitor or filter water separator vessels FDPM® MKII – Flow Differential Pressure Module, Mark II – provides automatic reporting of corrected differential pressure for varying flow rates. VCA® – Velcon Contaminant Analyzer for real-time fuel quality analysis in the field. For more information about any of Velcon’s products and to discuss your specific filtration requirements and fuel handling needs, please contact your local Velcon Representative. VCA-CV – the VCA combined with a Cla-Val valve. Sump Recovery System – for fuel savings and environmentally sound...
Open the catalog to page 5Filter/Separators are two-stage vessels designed to remove dirt and separate water from aviation fuel at refineries, product terminals, fuel farms, and on refueling vehicles. They continuously coalesce and separate water, which collects in the vessel sump where it can be drained. Velcon Filter/ Separators have passed numerous tests qualifying them to the latest EI 1581 edition. Construction is to ASME Code and EI1596 Specifications. Units qualified to military specifications are also available. ilitary Vessels Fixed Installations VV Vertical Vessels HV Horizontal Vessels V Vertical...
Open the catalog to page 6Micronic Filtration Micronic vessels offer economical particulate prefiltration upstream of clay units or Filter/Separators. Units meet EI1590 Specifications. Construction is to ASME Code Section VIII. Vessels Fixed Installations VF, VFAP (EI1590) Vertical Filter Vessels HF Horizontal Filter Vessels Pleated Filter Corrugated pleated media with large surface area for filtration of granular n f granular l contaminants. Also available in threaded base design. Fiberglass Filter Progressively finer layers of fiberglass filter colloidal or slimy my contaminants. Commissioning Cartridges...
Open the catalog to page 7Fuel Condition Monitoring & Control Velcon’s line of fuel condition monitoring solutions range from fixed on-line systems such as the Velcon Contaminant Analyzer (VCA®) to portable in-field systems such as the icountACM20, icountOS, and icountBSplus. All are designed to provide reliable accurate results in very short time. The VCA is an on-line monitoring system with the capability of detecting solid and liquid contaminants and can be configure d to shut off flow when contaminant levels exceeds your defined threshold. In addition, the telemetry option allows for remote monitoring on a...
Open the catalog to page 8icountACM20 STATEOFTHEART FUEL CONTAMINATION MONITORING. THE FIRST FULLY FUNCTIONAL PARTICLE COUNTER APPROVED FOR USE ON AVIATION FUELS. The icountACM20 Portable Particle Counter has been developed from existing technology for monitoring contamination in AVTur and other hydrocarbon fuels, in accordance with Energy Institute (EI) Method IP 564. In addition, the ACM can also be used to monitor fuels from existing sampling points in locations from refineries, pipelines, distribution terminals, fuel supply storage. APPLICATIONS Fuel Testing Laboratories - DEFSTAN 91-91 Issue 6 ...
Open the catalog to page 9Latin America Parker Comercio Ltda. Filtration Division Sao Paulo, Brazil +55 12 4009 3500 www.parker.com/br Pan American Division Miami, FL 305 470 8800 www.parker.com/panam Africa Aeroport Kempton Park, South Africa +27 11 9610700 www.parker.com/africa © 2014 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies. Parker Velcon Parker Hannifin Corporation Velcon Filtration Division 1210 Garden of the Gods Road Colorado Springs, CO 80907 USA tel +1 719 531 5855 www.velcon.com
Open the catalog to page 10i Automatic Air Eliminator Provides air vent to permit escape of trapped air during filling of vessel. When unit is completely filled with fuel, air eliminator automatically closes. 2 Check Valve Prevents air from siphoning into the vessel through the air eliminator. 3 Pressure Relief Valve This valve can be set to open at a desired pressure to exhaust excess pressure built up in the system, due to thermal expansion in a non-flow condition. 4 Coalescer Element Designed to remove solid contaminants, to break the emulsion of water in the product into droplets, and to enlarge these droplets so...
Open the catalog to page 119 Float Control Rides the interface between fuel and water, and by its up and down movement, opens and closes ports to generate hydraulic signals to automatic valves. Velcon recommends the “ballast” type float control for easier checking of the integrity of the float ball. 10 Pressure Gauge The direct reading differential pressure gauge is used to measure the pressure difference between the inlet and outlet of a filter/separator, thus providing an indication of element condition. © 2014 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective...
Open the catalog to page 12V and VV Series Vertical Filter/Separators Compact Filter/Separator Vessels for Fixed Installations FEATURES Compact Design Code Qualification Simplified Maintenance Field Proven Performance DESCRIPTION Units are designed for ease of maintenance with one piece threaded base coalescers and reusable one-piece Teflon® coated screen separators. The 85 Series coalescer cartridges used in most of these vessels have been field proven to give exceptionally long service life. NOTE: These vessels were previously qualified to API 1581 3rd Edition, which has been superseded by EI 1581 5th...
Open the catalog to page 13All Parker Racor Division catalogs and technical brochures
-
Low Lead Brass Valves
24 Pages
-
Racor Filter Division Europe
36 Pages
-
Turbine Series - 500FG
2 Pages
-
ECO III Air Filtration
8 Pages
-
FBO-14-HTR Heater Kit
2 Pages
-
Hydrocarbon Filtration Products
24 Pages
-
AFCS Series
2 Pages
-
Air Filtration
36 Pages
-
AFAP Series
2 Pages
-
Racor Filtration Division Europe
36 Pages
-
Filtres Racor Europe
32 Pages
-
Crankcase Ventilation
12 Pages
-
CCV4500
2 Pages
-
AF M701212
2 Pages
-
Air Filtration Systems
30 Pages
Archived catalogs
-
Hydraulic Filtration Solutions
20 Pages
-
Parker_in_Romania
15 Pages
-
Ground Fuel Handling Solutions
20 Pages
-
Fuel Filtration Systems
28 Pages
-
Hydrocarbon Filtration Products
24 Pages
-
Off-Highway Market
4 Pages