CNG Vehicle and Fueling Products from Parker's Quick Coupling Division
14Pages

{{requestButtons}}

Catalog excerpts

CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 1

climate control process control sealing & shielding CNG Vehicle and Fueling Products from Parker's Quick Coupling Division Fueling Nozzles, Vehicle Receptacles, In-line Vent ENGINEERING YOUR SUCCESS.

Open the catalog to page 1
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 2

CNG A leader in the design and manufacture of products and systems that convey and utilize compressed natural gas (CNG), Parker is a natural for natural gas. Our proven products for CNG dispensing and vehicle fueling provide improved service, reduced risk and global interchangeability.

Open the catalog to page 2
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 3

Parker FMS Series receptacles are designed for rigid mounting on a compressed natural gas vehicle. Receptacles can be employed in both fast-fill and time-fill dispensing applications. The ANSI/NGV1 standard used by FMS Series receptacles allows vehicle fueling to be accomplished with all CNG nozzles conforming to the ANSI/NGV1 standard. Features: •  FMS Series receptacles are certified to ANSI/CSA/NGV1 standards •  Receptacle employs a differential pressure-actuated valve •  Internal check valve provides unidirectional flow-natural gas will only flow from dispenser to vehicle •  Seal is a...

Open the catalog to page 3
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 4

Part Number 1/4" A-Lok Bulkhead 3/8" A-Lok Bulkhead 1/2" A-Lok Bulkhead 6mm A-Lok Bulkhead 8mm A-Lok Bulkhead Part Number Contact the Quick Coupling Division for other port configurations.

Open the catalog to page 4
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 5

Parker FMS Series receptacles are designed for rigid mounting on a compressed natural gas vehicle. Receptacles can be employed in both fast-fill and time-fill dispensing applications. The filter element eliminates contaminants from the environment and unclean compressed natural gas sources. It serves both as a prefilter to on-board vehicle components and protection for the FMS receptacle valving and seals. Features: •  FMS receptacles are certified to ANSI/CSA/NGV1 standards •  Filter element protects valving and seals from external contaminants that can be introduced during fueling • ...

Open the catalog to page 5
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 6

Parker FMS Series high flow receptacles are designed to meet or exceed the requirements of ANSI/NGV1 standards for compressed natural gas vehicle fueling devices. The high flow receptacles allow transfer of CNG fuel to the vehicle at a significantly higher flow rate than standard receptacles. High Flow Features: •  Compact size •  High flow rates •  Superior poppet check valve design •  Connects with any NGV1 compliant nozzle •  Allows for decreased fill times while using conventional NGV1 fueling nozzles Materials of Construction Body Stainless Steel Stainless Steel Stainless Steel...

Open the catalog to page 6
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 7

FUELING STATION Nozzles Push-to-Connect Refueling Nozzles Located on CNG fueling dispensers, Parker’s NGVC2 Nozzle easily connects with FMS Series receptacles and others certified to ANSI/CSA/NGV1 standards. Features: •  Certified to ANSI/CSA/NGV1 standards •  This nozzle can be classified as type 2 or 3 and can be used for both fast-fill and time-fill service •  Left-hand thread configurations are available for use on home refueling dispensers •  Push-to-connect, manually retract sleeve to disconnect •  Non-marring polyurethane sleeve protects vehicle body from surface damage •  Durable...

Open the catalog to page 7
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 8

FUELING STATION Nozzle Dock Parker’s NGVND Nozzle Dock provides a secure location on the fueling dispenser for the nozzle to reside when not in use. The Nozzle Dock keeps the nozzle clean, contained and readily accessible. Features: •  Material is corrosion resistant aluminum •  Lock washer keeps the dock secure for repeated use •  Compatible with all ANSI/CSA/NGV1 fueling nozzles Part Number NGVND

Open the catalog to page 8
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 9

FUELING STATION Breakaway - Fill Line Parker’s NGVBCN2-P50 fill line breakaway provides an important safety feature for CNG dispensing systems. It is certified to ANSI/NGV4.4/CSA12.54 standards for breakaway devices used on natural gas dispensing hoses and systems. It allows the hose to safely disconnect, preventing damage to the dispenser in the event of a "drive off" and sealing the CNG in the fill line to effectively prevent leakage or hose whip. Features: •  Exclusive design •  Pressure balanced •  Reliable consistent performance •  Compact size •  Reusable following breakaway (with...

Open the catalog to page 9
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 10

FUELING STATION Breakaway - Vent Line Parker’s vent line breakaway provides an important safety feature for CNG dispensing systems. It allows the vent line hose to safely disconnect, preventing damage to the dispenser in the event of a "drive off" and allows any CNG remaining in the vent line to bleed off safely. Features: •  Reliable consistent performance •  Compact size •  Reusable following breakaway (with minimal inspection) Materials of Construction Brass and Stainless with Nitrile and Urethane Seals Service Pressure 3600 psi with the Coupler Outlet Port open to atmosphere If Coupler...

Open the catalog to page 10
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 11

SAFETY GUIDE SAFETY GUIDE FOR SELECTING AND USING QUICK ACTION COUPLINGS AND RELATED ACCESSORIES DANGER: Failure or improper selection or improper use of quick action couplings or related ac­ es­ o­ ies can c s r cause death, personal injury and property damage. Pos­ i­ le consequences of failure or improper selection or sb improper use of quick action cou­ lings or related accessories include but are not limited to: p • Couplings or parts thrown off at high speed. • Dangerously whipping hose. • High velocity fluid discharge. • Contact with conveyed fluids that may be hot, • Explosion or...

Open the catalog to page 11
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division - 12

SAFETY GUIDE 2.10 Vacuum:  Not all quick action couplings are suitable or rec­ m­ end­ d for vacuum service. Quick action couplings used o m e for vacuum applications must be selected to ensure that the quick actions couplings will withstand the vacuum and pressure of the system. 2.11  Fire Resistant Fluids:  Some fire resistant fluids require seals other than the standard nitrile used in many quick action couplings. 2.12  Radiant Heat:  Quick action couplings can be heated to destruction or loss of sealability without contact by such nearby items as hot manifolds or molten metal. The same...

Open the catalog to page 12

All Parker Quick Coupling Division catalogs and technical brochures

  1. NSG series

    2 Pages

  2. UQD series

    2 Pages

  3. 2600 Series

    1 Pages

  4. ST Series