1. Catalogs
  2. Parker Quick Coupling Division
  3. CNG Vehicle and Fueling Products from Parker's Quick Coupling Division
video corpo

CNG Vehicle and Fueling Products from Parker's Quick Coupling Division

CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division
1 / 14 PagesView full catalog

CNG Vehicle and Fueling Products from Parker's Quick Coupling Division

Product catalog summary
Overview: The document is a catalog from Parker's Quick Coupling Division, focusing on products for CNG vehicle and fueling systems. It includes specifications, features, and safety guidelines for fueling nozzles, vehicle receptacles, and breakaway systems.
NGV1 Receptacles: Designed for rigid mounting on CNG vehicles, these receptacles are suitable for fast-fill and time-fill applications. They meet ANSI/NGV1 standards and include a differential pressure-actuated valve and an internal check valve for unidirectional flow. Constructed from stainless steel with a special nitrile compound seal.
Filtered Receptacles: These receptacles include a filter element to protect against contaminants, which is field replaceable, extending the life of downstream components.
High Flow Receptacles: Allow for higher flow rates, reducing fill times. They are compact and feature a superior poppet check valve design, compatible with any NGV1 compliant nozzle.
Push-to-Connect Refueling Nozzles: Certified to ANSI/CSA/NGV1 standards, these nozzles are suitable for both fast-fill and time-fill services. They feature a durable ball locking design and a non-marring polyurethane sleeve to protect vehicle surfaces.
Nozzle Dock: Provides a secure and clean location for nozzles when not in use. Made from corrosion-resistant aluminum, it is compatible with all ANSI/CSA/NGV1 fueling nozzles.
Breakaway Systems: Designed to safely disconnect in the event of a "drive off," preventing damage and leakage. They are reusable after minimal inspection and certified to relevant standards.
Safety Guide: Offers comprehensive instructions for selecting and using quick action couplings, emphasizing fail-safe design, user responsibility, and adherence to specifications and standards. Key considerations include pressure, fluid compatibility, temperature, size, and environmental factors.
Introduction: Provides safety guidelines, installation instructions, maintenance procedures, and terms and conditions for using Parker quick action couplings and related accessories. Highlights potential risks associated with improper use.
Safety Guide:
  • Vacuum Applications: Ensure compatibility with system pressure.
  • Fire Resistant Fluids: Some fluids require non-standard seals.
  • Radiant Heat: Nearby heat sources can damage couplings and cause fires.
  • Welding and Brazing: Heating above 450°F can emit harmful gases and damage seals.
Installation Instructions:
  • Pre-Installation Inspection: Verify correct style, material, and catalog number. Test coupling halves before final installation.
  • Mixed Manufacturer Assemblies: Do not exceed the lowest pressure rating of the combined halves.
  • Fitting Installation: Use compatible sealants and avoid excessive torque to prevent damage.
  • Caps and Plugs: Use them to protect uncoupled parts from contamination.
  • Coupling Location: Ensure accessibility without exposing operators to hazards.
  • Hose Whips: Use to reduce damage risk and isolate mechanical vibrations.
Maintenance Instructions:
  • Visual Inspection: Replace couplings with cracks, leaks, or damaged parts immediately.
  • Functional Test: Test at maximum pressure to check for malfunctions and leaks.
  • Replacement Intervals: Consider based on service life, recommendations, or risk potential.
Terms and Conditions:
  • Price and Payment: Prices are valid for 30 days, excluding taxes. Payment is due within 30 days of invoice.
  • Delivery and Risk: Title and risk pass to the buyer upon shipment. Seller is not liable for delivery delays.
  • Warranty: Products are warranted against defects for 12 months or 2,000 hours of use.
  • Claims: Must be reported within specified timeframes. Actions must commence within 12 months of breach.
  • Limitation of Liability: Seller's liability is limited to repair, replacement, or refund of the purchase price.
  • User Responsibility: Users must ensure product suitability and compliance with standards.
  • Force Majeure: Seller is not liable for delays due to uncontrollable events.
  • Governing Law: The agreement is governed by Ohio law, with disputes resolved in Cuyahoga County courts.
Intellectual Property and Liability: The seller controls defense against intellectual property infringement allegations. If a product infringes on third-party rights, the seller may allow continued use, replace, modify, or accept the return of the product with depreciation. The seller is not liable for infringement claims based on buyer-provided information or modifications.
Entire Agreement: States that the agreement is the complete and exclusive expression of the terms of sale, merging all prior negotiations.
Compliance with Laws: The buyer must comply with applicable laws, including the U.K. Bribery Act and U.S. Foreign Corrupt Practices Act, and indemnify the seller against violations. The buyer certifies adherence to these laws, particularly regarding payments to influence purchases.
Contact Information: Provides contact details for various divisions of Parker Hannifin Corporation, including Quick Coupling, Fluid Control, Hose Products, Parflex, Tube Fittings, and Filtration Divisions, along with their addresses, phone numbers, and fax numbers.
See more

Catalog excerpts

CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-1

climate control process control sealing & shielding CNG Vehicle and Fueling Products from Parker's Quick Coupling Division Fueling Nozzles, Vehicle Receptacles, In-line Vent ENGINEERING YOUR SUCCESS.

 Open the catalog to page 1
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-2

CNG A leader in the design and manufacture of products and systems that convey and utilize compressed natural gas (CNG), Parker is a natural for natural gas. Our proven products for CNG dispensing and vehicle fueling provide improved service, reduced risk and global interchangeability.

 Open the catalog to page 2
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-3

Parker FMS Series receptacles are designed for rigid mounting on a compressed natural gas vehicle. Receptacles can be employed in both fast-fill and time-fill dispensing applications. The ANSI/NGV1 standard used by FMS Series receptacles allows vehicle fueling to be accomplished with all CNG nozzles conforming to the ANSI/NGV1 standard. Features: •  FMS Series receptacles are certified to ANSI/CSA/NGV1 standards •  Receptacle employs a differential pressure-actuated valve •  Internal check valve provides unidirectional flow-natural gas will only flow from dispenser to vehicle •  Seal is a special...

 Open the catalog to page 3
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-4

Part Number 1/4" A-Lok Bulkhead 3/8" A-Lok Bulkhead 1/2" A-Lok Bulkhead 6mm A-Lok Bulkhead 8mm A-Lok Bulkhead Part Number Contact the Quick Coupling Division for other port configurations.

 Open the catalog to page 4
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-5

Parker FMS Series receptacles are designed for rigid mounting on a compressed natural gas vehicle. Receptacles can be employed in both fast-fill and time-fill dispensing applications. The filter element eliminates contaminants from the environment and unclean compressed natural gas sources. It serves both as a prefilter to on-board vehicle components and protection for the FMS receptacle valving and seals. Features: •  FMS receptacles are certified to ANSI/CSA/NGV1 standards •  Filter element protects valving and seals from external contaminants that can be introduced during fueling •  Filter...

 Open the catalog to page 5
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-6

Parker FMS Series high flow receptacles are designed to meet or exceed the requirements of ANSI/NGV1 standards for compressed natural gas vehicle fueling devices. The high flow receptacles allow transfer of CNG fuel to the vehicle at a significantly higher flow rate than standard receptacles. High Flow Features: •  Compact size •  High flow rates •  Superior poppet check valve design •  Connects with any NGV1 compliant nozzle •  Allows for decreased fill times while using conventional NGV1 fueling nozzles Materials of Construction Body Stainless Steel Stainless Steel Stainless Steel Specification...

 Open the catalog to page 6
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-7

FUELING STATION Nozzles Push-to-Connect Refueling Nozzles Located on CNG fueling dispensers, Parker’s NGVC2 Nozzle easily connects with FMS Series receptacles and others certified to ANSI/CSA/NGV1 standards. Features: •  Certified to ANSI/CSA/NGV1 standards •  This nozzle can be classified as type 2 or 3 and can be used for both fast-fill and time-fill service •  Left-hand thread configurations are available for use on home refueling dispensers •  Push-to-connect, manually retract sleeve to disconnect •  Non-marring polyurethane sleeve protects vehicle body from surface damage •  Durable ball...

 Open the catalog to page 7
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-8

FUELING STATION Nozzle Dock Parker’s NGVND Nozzle Dock provides a secure location on the fueling dispenser for the nozzle to reside when not in use. The Nozzle Dock keeps the nozzle clean, contained and readily accessible. Features: •  Material is corrosion resistant aluminum •  Lock washer keeps the dock secure for repeated use •  Compatible with all ANSI/CSA/NGV1 fueling nozzles Part Number NGVND

 Open the catalog to page 8
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-9

FUELING STATION Breakaway - Fill Line Parker’s NGVBCN2-P50 fill line breakaway provides an important safety feature for CNG dispensing systems. It is certified to ANSI/NGV4.4/CSA12.54 standards for breakaway devices used on natural gas dispensing hoses and systems. It allows the hose to safely disconnect, preventing damage to the dispenser in the event of a "drive off" and sealing the CNG in the fill line to effectively prevent leakage or hose whip. Features: •  Exclusive design •  Pressure balanced •  Reliable consistent performance •  Compact size •  Reusable following breakaway (with minimal...

 Open the catalog to page 9
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-10

FUELING STATION Breakaway - Vent Line Parker’s vent line breakaway provides an important safety feature for CNG dispensing systems. It allows the vent line hose to safely disconnect, preventing damage to the dispenser in the event of a "drive off" and allows any CNG remaining in the vent line to bleed off safely. Features: •  Reliable consistent performance •  Compact size •  Reusable following breakaway (with minimal inspection) Materials of Construction Brass and Stainless with Nitrile and Urethane Seals Service Pressure 3600 psi with the Coupler Outlet Port open to atmosphere If Coupler Outlet...

 Open the catalog to page 10
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-11

SAFETY GUIDE SAFETY GUIDE FOR SELECTING AND USING QUICK ACTION COUPLINGS AND RELATED ACCESSORIES DANGER: Failure or improper selection or improper use of quick action couplings or related ac­ es­ o­ ies can c s r cause death, personal injury and property damage. Pos­ i­ le consequences of failure or improper selection or sb improper use of quick action cou­ lings or related accessories include but are not limited to: p • Couplings or parts thrown off at high speed. • Dangerously whipping hose. • High velocity fluid discharge. • Contact with conveyed fluids that may be hot, • Explosion or burning...

 Open the catalog to page 11
CNG Vehicle and Fueling Products  from Parker's Quick Coupling Division-12

SAFETY GUIDE 2.10 Vacuum:  Not all quick action couplings are suitable or rec­ m­ end­ d for vacuum service. Quick action couplings used o m e for vacuum applications must be selected to ensure that the quick actions couplings will withstand the vacuum and pressure of the system. 2.11  Fire Resistant Fluids:  Some fire resistant fluids require seals other than the standard nitrile used in many quick action couplings. 2.12  Radiant Heat:  Quick action couplings can be heated to destruction or loss of sealability without contact by such nearby items as hot manifolds or molten metal. The same heat...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.