Introduction
Parker Hannifin Precision Fluidics Division introduces the X-Flow™ Mass Flow Controller, designed for various applications including instrumentation, lab, and process needs. It offers high accuracy flow control using Constant Thermal By-Pass Mass Measurement Technology and supports popular digital communication protocols.

Key Features
  • Constant Heat Thermal By-Pass Sensor: Reliable technology with minimal pressure impact and low pressure drop.
  • Proportional Valve: Utilizes solenoid technology, orientation independent, and digitally controlled.
  • Laminar Flow Element & Turbulence Filter: Ensures accurate measurements despite flow disturbances.

Applications
Suitable for analytical instrumentation, pharma/bio-pharma, emissions monitoring, and process industry needs.

Software and Asset Management
  • Parker Floware: Free software for monitoring flow signals and setting alarms.
  • Parker Tracking System (PTS): Asset management system for tracking conditions and documentation.

Product Specifications
  • Accuracy: ±1.0% Full Scale
  • Turndown Ratio: 50:1
  • Operating Temperature: 32 to 122°F (0 to +50°C)
  • Operating Pressure: 145 PSIG (10 Barg)
  • Material: Stainless Steel 316L or comparable, FKM seals
  • Power Supply: +15-24 Vdc
  • Digital Communication: RS232, Modbus-RTU, Modbus-ASCII (RS485)

Ordering Information
Includes various gas flow ranges and accessories for different applications. The product supports a wide range of gases, ensuring compatibility with diverse needs.

Recommendations
Users should conduct tests to determine product suitability for specific applications. Parker provides guidance on application design and material selection based on available data.
See more

Catalog excerpts

X-Flow™-1

X-Flow™ Mass Flow Controller ENGINEERING YOUR SUCCESS.

 Open the catalog to page 1
X-Flow™-2

X-Flow™ Mass Flow Controller Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow™, a new easy to use general purpose mass flow controller for your instrument, lab, or process needs. X-Flow™ delivers fast, repeatable, and reliable high accuracy flow control through proven Constant Thermal By-Pass Mass Measurement Technology coupled with our most popular digital communication protocols. Constant Heat Thermal By-Pass Sensor • Proven and reliable technology • Great low range flow measurements • Minimal impacts from pressure changes • Low pressure drop and blockage...

 Open the catalog to page 2
X-Flow™-3

X-Flow™ Mass Flow Controller Designed and Produced with Simplicity in Mind for: • Analytical Instrumentation • Pharma / Bio Pharma • Emissions Monitoring • Process Industry Needs Included asset management system Parker Tracking System (PTS) • Reduce downtime with automatic reminders based on your calibration cycle • Track your asset’s specific conditions • Centralized location for all documentation Learn more at www.parker.com/PTS Parker Floware: Included free software tools to get the most out of your unit: • View your Flow Signal, Set Point and Output Signal on a graph • Flexibility around...

 Open the catalog to page 3
X-Flow™-4

Measurement / Control System Accuracy Turndown Repeatability Controller Settling Time Control Stability Controllable Flow Range Full Scale Calibration Range Operating Temperature Operating Pressure Temperature Sensitivity Zero Leak Integrity (External) Warm-Up Time Control Valve ±1.0% Full Scale 50:1 <0.2% of Reading 1 second (Nominal) <±0.1% Full Scale (typical for 1 l/min N2) 0.8 ml/min to 20 l/min 40 ml/min to 20 l/min 32 to 122°F, 0 to +50°C 145 PSIG, 10 Barg <0.1% Full Scale/°C; span: <0.1% Reading/°C Tested < 2 x 10-9 mbar l/s He ±2% Full Scale after 2 min, ±1.0% Full Scale after 30 min...

 Open the catalog to page 4
X-Flow™-5

X-Flow™ Mass Flow Controller Gas Flow Range The selected orifice of the control valve may limit the rangeability Standard accuracy (based on actual calibraiton): +/- 1% FS Factors for gas not in the above table are available from the factory All flow ranges are standard conditions of 14.7 PSIA and 0oC Base Model--------- Nitrogen Full Scale Equivalent Flow Range4 •Btandaid DondttariB of 14.7 PBIAand 0"C 00 Hone i i-------------- Supply Voltage D +15-24 Vdlc Analog I/O A 0-5 Vdc G 4-20 mAdc Sourcing Communication (I/O) A Analog + RS232 or ModBus™ Accessories B-1562-039V: 1/8” Compression Fitting...

 Open the catalog to page 5
X-Flow™-6

X-Flow™ Mass Flow Controller Chemical Compatibility Chart X-Flow’s robust proven sensor technology offers a wide variety of gasses that are compatible for use.

 Open the catalog to page 6
X-Flow™-7

X-Flow™ Mass Flow Controller Serving a broad spectrum of life science, air quality, and process instrumentation OEM fluidic needs Providing Pressure and Vacuum: Broad range of diaphragm pumps for Gas and Liquid Gas Flow Control: High to Low Flow Proportional Valves On/Off & Channel Selection Capabilities: Gas and Liquid Solenoid Valves High Precision Thermal Flow Control: Mass Flow Controllers and Meters

 Open the catalog to page 7
X-Flow™-8

Learn More at: solutions.parker.com/X-Flow Below are some common specifications that are helpful to have on hand to accelerate your product selection: • Gas Type • Standard Reference Conditions • Maximum Flow Rate • Process Connection Size and Type • Inlet and Outlet Pressures • Set Point Signal • Operating Temperature • Digital Communication Protocol Preferences For more information call +1 603 595 1500 or email [email protected] Visit www.parker.com/precisionfluidics Recommendations on application design and material selection are based on available technical data and are offered as suggestions...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.