Global FRL Air Preparation System
82Pages

{{requestButtons}}

Catalog excerpts

Global FRL Air Preparation System - 1

Global FRL Air Preparation System Fully Modular 1/4" to 3/4" Body Ports Catalogue PDE2676TCUK September 2020

Open the catalog to page 1
Global FRL Air Preparation System - 2

Parker Global Air Preparation System DECLARATION OF COMPLIANCE (ROHS) Following Ignition Hazard Assessments performed on the non-electrical Global Air Preparation products they are in accordance with the requirements of EN 13463-1:2009, it was considered that the equipment does not contain its own source of ignition, and therefore is not within the scope of directive 94/9/EC. European Directive 2011/65/EU – RoHS (Restriction us of certain Hazardous Substances in electrical and electronic equipment), restricts the use of the 6 substances in the manufacture of specified electrical equipment....

Open the catalog to page 2
Global FRL Air Preparation System - 3

Parker Hannifin Corporation Pneumatic Division - Europe

Open the catalog to page 3
Global FRL Air Preparation System - 4

Parker Global Air Preparation System Parker Global Air Preparation System Global. Modular. Performance you need, wherever you need it. Full featured particulate and coalescing filters, regulators, filter/regulators, and lubricators are available with a wide range of standard options to meet air preparation needs. The comprehensive Global Air Preparation System is available in three body sizes with either BSPP or NPT to accommodate thread type requirements. Individual units can easily be assembled into various combinations, utilizing patented modular lightweight body connectors. Parker...

Open the catalog to page 4
Global FRL Air Preparation System - 5

Parker Global Air Preparation System A completely modular air preparation system Soft Start / Dump Valve Easy to adjust non-rising knob with snap-lock, preventing accidental change of set pressure 2-piece Patented modular body connector US Patent number 5,383,689 Filter / Regulator Pressure gauge Ball Valve Aluminum body NPT or BSPP porting available Coalescing Filter Padlock slide Quick release bayonet-type integral bowl and bowl guard assembly Bowl guard with multiple viewing slots Manual drain with pipe-away, auto drain available Optional Tamperproof Kits • One facilitates the permanent...

Open the catalog to page 5
Global FRL Air Preparation System - 6

Parker Global Air Preparation System Together we can power your application with clean, dry air Fast cycle times, high product quality, and low downtime all require a clean, dry pneumatic system to function properly. Parker has what it takes to make sure pneumatic systems perform at their best. Clean, dry pneumatic systems with Parker Global Air Preparation As air is compressed to 7 bar (100 psig) and higher, the relative humidity quickly reaches 100% RH and air temperatures can reach between 110°C and 200°C (230°F and 392°F). 2 For every 11C (20F) that the air cools after leaving the heat...

Open the catalog to page 6
Global FRL Air Preparation System - 7

Parker Global Air Preparation System Bulk Liquid Removal Particulate Filtration Coalescing Filtration Basic pneumatic systems Basic pneumatic systems Systems requiring Systems requiring highest quality air. air with reduced moisture content Systems requiring highest quality air for critical applications Air leaving the compressor room at 93ºC (200ºF) releases 95% of its moisture into the piping system when it cools to 38ºC (100ºF) Removes bulk liquid contamination and protects filters where excess cooling takes place in the distribution piping Removes solid particulates down to 5 micron,...

Open the catalog to page 7
Global FRL Air Preparation System - 8

Parker Global Air Preparation System Specifying air quality (purity) in accordance with ISO8573-1:2010, the international standard for compressed air quality ISO8573-1 is the primary document used from the ISO8573 series as it is this document which specifies the amount of contamination allowed in each cubic metre of compressed air. ISO8573-1 lists the main contaminants as Solid Particulate, Water and Oil. The purity levels for each contaminant are shown separately in tabular form, however for ease of use, this document combines all three contaminants into one easy to use table. Solid...

Open the catalog to page 8
Global FRL Air Preparation System - 9

Parker Global Air Preparation System Application Guide FRL to Valve: The chart below contains recommendations for the correct selection of Global Air Preparation units to suit the number and size of valves in a typical application. P31 Mini Series Number of valves that would actuate at once 1 Moduflex 1 Isys Micro HB / Viking Xtreme Moduflex 2 HA / Global ISO See Larger Parker FRL Offering Actuator to FRL: The chart below contains recommendations for the correct selection of Global Air Preparation units suitable for each cylinder size. If you have a tube length over 2 m, choose one tube...

Open the catalog to page 9
Global FRL Air Preparation System - 10

Parker Global Air Preparation System Comprehensive Offering 1/4" ports 40mm body width • 5µ particulate, 1.0µ and 0.01µ coalescing, and adsorber available as standard • Available as stand alone, common port and electronic proportional • Transparent or metal bowl with manual or auto float drains standard • Both relieving and nonrelieving versions available P33 Standard Series 1/2" and 3/4" 73mm body width Filter / Regulators • Compact design for space savings • Available with all the same standard options as the filters and regulators • Proportional oil delivery over a wide range of air...

Open the catalog to page 10
Global FRL Air Preparation System - 11

Parker Global Air Preparation System Air Preparation P31 Mini Series 40mm body width 1/4" Ported Flows up to: dm3/s Filter 12 Coalescer 3,6 Regulator 32 Filter/Regulator 35 Lubricator 25 Features: • Space saving integral gauge • Manifold style regulators available • OSHA compliant shut-off valves • Soft-Start & Quick Dump valves • Electronic Proportional Regulator P32 Compact Series 60mm body width 1/4", 3/8", & 1/2" Ported dm3/s Flows up to: Filter 39 Coalescer 17 Regulator 78 Filter/Regulator 77 Lubricator 42 Features: • Manifold style regulators available • OSHA Compliant shut-off valves...

Open the catalog to page 11
Global FRL Air Preparation System - 12

Parker Global Air Preparation System Popular Combinations: Filter + Regulator + Lubricator Combinations, Poly bowl 5 micron element, 8 bar (116 psig) regulator + gauge and wall mounting brackets Port size Manual drain 27 (scfm) Pulse drain Filter/Regulator + Lubricator Combinations, Poly bowl 5 micron element, 8 bar (116 psig) regulator + gauge and wall mounting brackets Port size 1/4" Manual drain Pulse drain Ball Valve + Filter + Regulator + Lubricator Combinations, poly bowl 5 micron element, 8 bar (116 psig) regulator + gauge and wall mounting brackets Port size Manual drain 27 (scfm)...

Open the catalog to page 12

All Parker Pneumatic Division Europe catalogs and technical brochures

  1. Dryer Products