Laboratory Membrane Air Dryers
3Pages

{{requestButtons}}

Catalog excerpts

Laboratory Membrane Air Dryers - 1

Laboratory Membrane Air Dryers ▲ Low dewpoint instrument air - prevents analytical instrument contamination electricity required - low operating costs refrigerants or freons - environmentally sound moving parts or motors - silent operation The Parker Balston® 64-01, 64-02 and 64-10 Membrane Air Dryers will supply oil and particulate free dry compressed air to atmospheric dewpoints as low as -40°F (-40°C), and at flow rates of up to 25 SCFM. Parker Balston Membrane Air Dryers are engineered for easy installation, operation, and long term reliability. The dryers incorporate the highest efficiency membrane available, offering low cost operation and minimal maintenance. Parker Balston Membrane Air Dryers are designed to operate continuously, 24 hours per day, 7 days per week. The only maintenance required is changing the prefilter cartridge once each year. This annual maintenance takes approximately 5 minutes. The dryers are lightweight, compact, and can be easily installed on an existing air line. In a vertical or horizontal orientation (depending upon model), a high efficiency coalescing prefilter is installed directly upstream from the dryer module to protect the membrane from potential contamination caused by pipe scale, liquids, or other solids. Parker Balston Membrane Air Dryers require no electrical connections, making them ideal for remote and point-of-use installations or for installation in hazardous areas. Water Vapor Water vapor quickly permeates the membrane, and is released harmlessly to atmosphere. Air flows along the membrane fiber as a separate product stream.

Open the catalog to page 1
Laboratory Membrane Air Dryers - 2

Notes: 1 Dewpoint specified with inlet air at 100°F (38°C) saturated at 100 psig. Principal Specifications Membrane Air Dryers Min/Max Inlet Air Temp. (2) Recommended Operating Temp. Range Min/Max Inlet Pressure Maximum Pressure Drop Wall Mountable Inlet/Outlet Port Size Electrical Requirements 1/4” NPT (female) 1/4” NPT (female) 1/2” NPT (female) Shipping Weight 2 Inlet compressed air dewpoint must not exceed the ambient air temperature. Ordering Information for assistance, call 800-343-4048, 8 to 5 Eastern Time Description Model Number Parker Balston Membrane Dryer Pressure Regulator...

Open the catalog to page 2
Laboratory Membrane Air Dryers - 3

Ultra Dry Gas Generator ▲ Supplies ultra-dry, purified compressed air to NMR Spectrometers and other analytical instruments gas supply for spindle and automatic sample changer eliminates costly, inconvenient nitrogen dewars - never pay for or change out another dewar design frees up valuable laboratory floor automatic - plug it in and forget about it The Parker Balston® Model UDA-300NA Compressed Air Dryer provides ultra-dry, purified compressed air to analytical instruments. The model UDA-300 reduces the dewpoint to -100°F (-73°C) without operator attention. Each system is delivered...

Open the catalog to page 3