Overview: The Parker Balston FT-IR purge gas generator is designed to convert standard compressed air into a clean, dry, and CO2-free purge gas. It serves as an efficient alternative to nitrogen, enhancing the quality of background spectra and reducing analysis time.
Key Features:
  • Provides a continuous supply of purge gas for FT-IR systems at a lower cost than nitrogen.
  • Compatible with FTIR microscopes and accessories.
  • Eliminates the need for nitrogen cylinders in laboratories.
  • Improves signal-to-noise ratio, resulting in cleaner spectra in less time.
  • Simple and low-cost annual maintenance.
Technical Specifications:
  • Utilizes filtration and pressure swing adsorption (PSA) technology.
  • Removes contaminants down to 0.01 micron.
  • Produces ultra-pure dry air with a dew point of -73°C and CO2 concentration of less than 1 ppm.
  • Available models: 75-45, 75-52, 75-62 with flow rates of 14 lpm, 28 lpm, and 85 lpm respectively.
  • Operates at inlet/outlet pressure of 4.1 to 8.6 bar.
  • Electrical requirements: 230 VAC - 50Hz - 12VDC, 100 Watts.
  • Operating ambient temperature: 10 to 35°C.
Model Specifications:
  • Model 75-45: Dimensions: 330 x 320 x 180 mm, Weight: 10 Kg.
  • Model 75-52: Dimensions: 710 x 320 x 220 mm, Weight: 24 Kg.
  • Model 75-62: Dimensions: 1120 x 320 x 220 mm, Weight: 36 Kg.
Maintenance: Maintenance kits are available for each model, ensuring optimal performance and longevity.
Contact Information: Parker Hannifin (UK) Limited, Process Air and Gas Business Unit, Hermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT. Phone: +44 (0)1622 723300, Email: [email protected], Website: www.parker.com/pag
See more

Catalog excerpts

S3.2.012a - FT-IR 75-45_52_62 "FT-IR Purge Gas Generators for Fourier Transform-Infrared"-1

FT-IR Purge Gason Demand, up to 85 lpm FT-IR Purge Gason Demand, up to 85 lpm FT-IR Purge Gason Demand, up to 85 lpm The Parker Balston FT-IR purge gas generator is engineered to transform standard compressed air into a clean supply of dry (-73 The Parker Balston FT-IR purge gas generator is engineered to transform standard compressed air into a clean supply of dry (-73 > The Parker Balston FT-IR purge gas generator is engineered to transform standard compressed air into a clean supply of dry (-73 The Parker Balston FT-IR purge gas generator is engineered to transform standard compressed air into a clean supply of dry (-73 The Parker Balston FT-IR purge gas generator is engineered to transform standard compressed air into a clean supply of dry (-73 а а c), CO c), CO > c), CO c), CO c), CO 2 2 2 2 2 free (<1 ppm) purge gas. The FT-IR gas generators are an ideal alternative to nitrogen, producing cleaner background spectra in a shorter time. Payback periods are typically less than one year. By removing CO free (<1 ppm) purge gas. The FT-IR gas generators are an ideal alternative to nitrogen, producing cleaner background spectra in a shorter time. Payback periods are typically less than one year. By removing CO > free (<1 ppm) purge gas. The FT-IR gas generators are an ideal alternative to nitrogen, producing cleaner background spectra in a shorter time. Payback periods are typically less than one year. By removing CO free (<1 ppm) purge gas. The FT-IR gas generators are an ideal alternative to nitrogen, producing cleaner background spectra in a shorter time. Payback periods are typically less than one year. By removing CO free (<1 ppm) purge gas. The FT-IR gas generators are an ideal alternative to nitrogen, producing cleaner background spectra in a shorter time. Payback periods are typically less than one year. By removing CO 2 2 2 2 2 and water vapour the signal to noise ratio allows more accurate analysis, particularly from 1,200-2,000, 2,400 and 3,600- 4,000 wave numbers. and water vapour the signal to noise ratio allows more accurate analysis, particularly from 1,200-2,000, 2,400 and 3,600- 4,000 wave numbers. > Product Features: Product Features: Product Features: Parker Hannin (UK) Limited Parker Hannin (UK) Limited Parker Hannin (UK) Limited Parker Hannin (UK) Limited Parker Hannin (UK) Limited Process Air and Gas Business Unit Process Air and Gas Business Unit Process Air and Gas Business Unit Process Air and Gas Business Unit Process Air and Gas Business Unit Hermitage Court, Hermitage Lane Maidstone, Kent ME16 9NT Hermitage Court, Hermitage Lane Maidstone, Kent ME16 9NT > Օ Produces a continuous supply of purge gas for FT-IRs at a fraction of the cost of nitrogen ҕ Can supply FTIR with microscopes and other accessories Eliminate costly nitrogen cylinders in the laboratory Օ Recommended and used by all leading FT-IR manufacturers Improve signal-to-noise ratio even on non-purge systems - cleaner spectra in a shorter timeՕ Simple, low cost annual maintenance Produces a continuous supply of purge gas for FT-IRՒs at a fraction of the cost of nitrogen Can supply FTIR with microscopes and other accessoriesՕ Eliminate costly nitrogen cylinders in the laboratory Recommended and used by all leading FT-IR manufacturersՕ Improve signal-to-noise ratio even on non-purge systems - cleaner spectra in a shorter time Simple, low cost annual maintenance Օ Produces a continuous supply of purge gas for FT-IRs at a fraction of the cost of nitrogen ҕ Can supply FTIR with microscopes and other accessories Eliminate costly nitrogen cylinders in the laboratory Օ Recommended and used by all leading FT-IR manufacturers Improve signal-to-noise ratio even on non-purge systems - cleaner spectra in a shorter timeՕ Simple, low cost annual maintenance phone +44 (0)1622 723300fax +44 (0)1622 728703 [email protected] phone +44 (0)1622 723300fax +44 (0)1622 728703 [email protected] phone +44 (0)1622 723300fax +44 (0)1622 728703 [email protected] phone +44 (0)1622 723300fax +44 (0)1622 728703 [email protected] phone +44 (0)1622 723300fax +44 (0)1622 728703 [email protected] www.parker.com/pag www.parker.com/pag > Analytical Gas Systems Analytical Gas Systems Analytical Gas Systems size="-1">

 Open the catalog to page 1
S3.2.012a - FT-IR 75-45_52_62 "FT-IR Purge Gas Generators for Fourier Transform-Infrared"-2

FT- IR purge gas is produced by utilising a combination of ltration and pressure swing adsorption (PSA) technology. An external supply of compressed air is ltered by high eciency coalescing lters to remove all contaminants down to 0.01 micron. e air then passes through two columns lled with molecular sieve which adsorb moisture and CO FT- IR purge gas is produced by utilising a combination of ltration and pressure swing adsorption (PSA) technology. An external supply of compressed air is ltered by high eciency coalescing lters to remove all contaminants down to 0.01 micron. e air then passes...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.