Parker icount Oil Sampler
12Pages

{{requestButtons}}

Catalog excerpts

Parker icount Oil Sampler - 1

climate control process control sealing & shielding Parker icount Oil Sampler (IOS) Portable condition monitoring for hydraulic ENGINEERING YOUR SUCCESS.

Open the catalog to page 1
Parker icount Oil Sampler - 2

Accurate condition monitoring made quick, simple and cost effective quality of hydraulic oils and hydrocarbon fuels in many different applications: from renewable energy, marine and mobile, agriculture, military and Compact, lightweight and robust, the truly portable IOS makes field analysis simple, quick and easy. fuel tank or from a high pressure online hydraulic system with the addition of a pressure reducing the most adaptable contamination service tool available today. The system is completely self contained, with laser detection particle counter, battery and pump plus memory with web...

Open the catalog to page 2
Parker icount Oil Sampler - 3

Wherever, whenever you need to be 100% sure of oil and fuel quality With its robust carrying case, sealed to IP67, and proven laser and diagnostics technologies, the IOS is the perfect tool for maintenance and plant engineers to use with all fixed and mobile plant and machinery. IOS technology is proven in many different applications, under the most demanding conditions, and is used by leading companies around the world. sector, IOS is ideally suited to service and fluid monitoring of essential equipment and services. provides essential condition monitoring support for mission critical...

Open the catalog to page 3
Parker icount Oil Sampler - 4

monitor for hydraulic oils and hydrocarbon fuels uses advanced technology to produce extremely repeatable results. sophisticated laser detector, using a light obscuration flow cell, providing continuous measurement of fluid flow passing through a sample tube. Measurements are taken every second as standard, although measurement intervals and test user, with results being reported real time. Data is displayed on a built-in OLED digital display and can also be stored for subsequent upload page interface connecting through Proven laser detection technology Parker's experience in developing...

Open the catalog to page 4
Parker icount Oil Sampler - 5

Dimensions are given in mm (inches) Low pressure connection setup We recommend that the IOS is positioned in a safe, stable area, as close as possible to the system output and only the hose fittings provided are used. High pressure connection setup (Optional equipment needed) (High pressure is defined for this unit as more than 2.5 bar, with a maximum of 350 bar) We recommend that the IOS is positioned in a safe, stable area, as close as possible to the system output and only the hose fittings provided are used. For pressure systems (more than 2.5 bar) one high pressure hose assemblies:...

Open the catalog to page 5
Parker icount Oil Sampler - 6

Features that boost your productivity

Open the catalog to page 6
Parker icount Oil Sampler - 7

Proven laser detecton technology The IOS uses light obscuration, light blockage technology. A light source is projected through a moving column of oil or fuel. Contaminants in the fluid interrupt the light beam, casting images on a photo diode cell, where the resulting change in light intensity produces a directly proportional change in electrical output. High onboard test data storage capacity Class leading onboard memory provides storage capacity for up to 250,000 sets of test results. Data is displayed instantly, stored or downloaded to a PC or laptop for analysis via a standard IP68 RJ...

Open the catalog to page 7
Parker icount Oil Sampler - 8

The IOS is a unique product in that which means that the stored data Utilising a computer's Internet Explorer utility, simply plug in the supplied network cable, open Explorer and enter the IOS's unique IP/MAC address. Home page Product description =B *m » COTILHI Mwvlu'Hf talk* bay^ii \m§ mliw-p nhrtr^lj a InUt iipnl * pr¥**i4r>] tytHtr am4 i LMpMfC hiiWni ttjmm t*m aataMMMtag tw kt+wrt ai íwwftrm *ñ n ty&aum. lu&-iHO-> anl+awi rrM0ta T-m»Ttm *«a 1ST EE«nn ** ; am Tcaw- -r- r^ trane iiWi b> Mot jnmis »,Ttm rH tw1-i>k -unni- E^vfrc «rd Emfepui «Am r' ^i"f' *A*H«-«vCÎ*AHi»JiH'-*r.r-ii i >im...

Open the catalog to page 8
Parker icount Oil Sampler - 9

Unit status page The Unit Status page is a list of current values Configuration page Alarm limit settings for: Alarm limit setting for Relative Humidity Measurement period Data logging interval Unit name Unit location set report standard page Confirm the selected standard

Open the catalog to page 9
Parker icount Oil Sampler - 10

Technical Specifications Important Information WARNING-USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. - This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. - The user, through their own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all...

Open the catalog to page 10
Parker icount Oil Sampler - 11

Ordering Information Accessory Part Numbers Part number (includes one power pack, pressure hose connectors) Pressure Reducing Valve (PRV) Power Pack (UK 2m cable) Power Pack (EUR 2m cable) Power Pack (US 2m cable) (Standard with Carry Strap High Pressure Hose Assembly Verification Fluid Part number The Carry Strap option (Standard with

Open the catalog to page 11
Parker icount Oil Sampler - 12

Parker Worldwide Europe, Middle East, Africa AE - United Arab Emirates, AT - Austria, Wiener Neustadt Wiener Neustadt BE/LU - Belgium, Nivelles CZ - Czech Republic, Klecany ES-Spain, Madrid FR - France, Contamine s/Arve PT - Portugal, Leca da Palmeira parker. portugal ©parker.com SK - Slovakia, Banská Bystrica SL - Slovenia, Novo Mesto UK - United Kingdom, Warwick ZA - South Africa, Kempton Park North America CA - Canada, Milton, Ontario Asia Pacific AU - Australia, Castle Hill KR - South Korea, Seoul MY - Malaysia, Shah Alam South America AR - Argentina, Buenos Aires BR - Brazil, Sao Jose...