Catalog excerpts
icount Particle Monitoring ACM20, ACM20 Z2, IPD and IBS Aviation fuel + hazardous zones monitoring
Open the catalog to page 1A unique product with pedigree DEFSTAN 91-91 Issue 6 Jet A-1Fuel Specification, adopts particle counting. Development work carried out by the CMC engineers, in conjunction with Exxon Mobil Aviation, highlighted the need for an alternative test method to determine the levels of dispersed contamination in Jet fuel. 5 years of field testing and development of the already established and successful icountLCM20 Hydraulic Laser Particle Counter saw the introduction of the Parker icountACM20 with enhanced software providing the user with a better understanding of the contamination present in a...
Open the catalog to page 3The Parker icountACM20 Portable Particle Counter has been developed from existing technology for monitoring contamination in AvTur and other hydrocarbon fuels, in accordance with the Energy Institute (EI) Method IP 564. In addition, the ACM can also be used to monitor various fuels from existing sampling points in locations from refineries, pipelines, distribution terminals, airport fuel supply systems all the way through to the point of uplift into aircraft*. * Hot works permit required for online sampling (ATEX Zone 2 unit available). Page 14. • Fuel Testing Laboratories – DEFSTAN 91-91...
Open the catalog to page 4397 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. icountACM20 - rear view Construction: ABS structural foam and injection moulded case Hand-held display - ABS Keypad flurosilicone rubber Mechanical Components: Brass, plated steel, stainless steel and aluminium Seals: Fluorocarbon Hoses: Nylon (Kevlar braided microbore). St. steel armoured ends Flow Rate: 25 - 28ml/min (dictated by CMP) 100ml/min with additional flush button Fluid Compatability: Hydrocarbon Fuel, Mineral Oil. For other fluids consult Parker Fuse: 1.25 amp fast blow fuse included for overload protection (spare...
Open the catalog to page 5398 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. DEFSTAN 91-91 Issue 6 Defence Standard 91-91 is the specification for aviation turbine fuel, which the United Kingdom Civil Aviation Authority (CAA) has agreed is under the technical authority of the Director of the Defence Fuels Group. IP 564 Laboratory determination of the level of dispersed contamination in aviation kerosene using an Automatic Particle Counter (APC). This standard describes a method for determining the level of dispersed contamination in aviation kerosene fuels, specifically dirt particles and water droplets...
Open the catalog to page 6For use in explosive and hazardous areas icountACM20 Z2 is designed to be used to monitor various fuels from existing sampling points in hazardous locations such as refineries, pipelines, distribution terminals, airport fuel supply systems all the way through to the point of uplift into aircraft. With Zone 2 classification, the icount ACM20 Z2 is the worlds only ATEX approved particle counter. Product Features: • Assembled in an approved and certified stainless steel enclosure to comply with ATEX Directive 94/9/EC. • Can be used in explosive and hazardous areas, including offshore and...
Open the catalog to page 7402 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. icountACM20 Z2 ATEX Approved Portable Particle Counter Features & Benefits Test Time: 2 minutes. Repeat Test Time: Every 2 minutes (Manual testing) Every 6 minutes (Automatic). Principle of Operation: Optical scanning analysis and measurement of actual particles and inference to water presence. Primary Output: 4ì(c), 6ì(c), 14ì(c), 21ì(c), 25ì(c), 30ì(c) counts per ml. Secondary Diagnostic Output: % Volume Distribution, via graphical display on handset. International codes: ISO 7-22 in accordance with ISO 4406-1999 Data entry:...
Open the catalog to page 8Specification Using icountACM20 Z2 Construction: Unit: Stainless Steel Carrying case: ABS Hand-held display: ABS Keypad: polyester membrane Mechanical components: Brass, plated steel, stainless steel and aluminium Seals: Fluorocarbon Hoses: Nylon (Kevlar braided microbore) Fluid compatibility: All fuels. For other fluids consult Parker Internal rechargeable battery: Note: ONLY to be charged outside of the hazardous area, with the unit switched off Fuse: 1.25A fast blow fuse included for overload protection Return to Parker Hannifin if fuse is blown icountACM20 2032 technology: Unique...
Open the catalog to page 9Installation Details icountACM20 Z2 ATEX Approved Portable Particle Counter Product number Supersedes Description icountACM20 Z2 + online kit & UK battery charger icountACM20 Z2 + online kit & US battery charger icountACM20 Z2 + online kit & Euro battery charger icountACM20 Z2 + online & lab kit + UK battery charger icountACM20 Z2 + online & lab kit + US battery charger icountACM20 Z2 + online & lab kit + Euro battery charger UK battery charger US battery charger Euro battery charger 2m process cable assembly Parsmart downloader software Carry case Bottle assembly Throttle kit Millipore...
Open the catalog to page 10405 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. Applications in hydraulics Solutions in the offshore industry. In addition, the icountACM20 Z2 can be used in many hydraulic system applications as detailed below. In many industries, worker awareness needs to be maintained at a high level to ensure the safety of their operation. This is particularly relevant to offshore oil-drilling and gas-drilling crews, given the interactive and hazardous nature of their work. The Zone II ACM portable particle analyser is a tried and tested technology designed, proven and approved as a...
Open the catalog to page 11406 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. icountACM20 Z2 ATEX Approved Portable Particle Counter Average Particle Counts in AV System The table below gives estimated counts found in a typical aviation fuel distribution system, and is given as guidance, in which API/EI filtration equipment is installed. Receipt into Microfilter Expect 2,500 counts per ml or cleaner @ 4ì(c) Receipt into Microfilter 4ì(c) 6ì(c) 14ì(c) ISO Code - 4406 1999 High Count 2,500 350 10 High Count Code 18 15 10 MF Receipt into FWS (After MF) 4ì(c) 6ì(c) 14ì(c) ISO Code - 4406 1999 High Count 500...
Open the catalog to page 12All Parker Hydraulic and Industrial Filtration Divisio catalogs and technical brochures
-