1. Catalogs
  2. Parker Hydraulic and Industrial Filtration Divisio
  3. Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS
video corpo

Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS

Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS
1 / 34 PagesView full catalog

Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS

Product catalog summary
Overview: This document provides comprehensive information on Parker Hannifin's icount particle monitoring systems, specifically designed for aviation fuel and hazardous zones. It covers models such as the icountACM20, icountACM20 Z2, IPD, and IBS, detailing their features, specifications, and applications.
1. icountACM20 Aviation Fuel Monitor:
  • Monitors aviation fuel contamination in compliance with DEFSTAN 91-91 Issue 6 Jet A-1 fuel specification and Energy Institute Test Method IP 564.
  • Features a 2-minute test procedure, laser optical scanning analysis, and multi-standard ISO cleanliness reporting.
  • Portable with a built-in pump, suitable for various locations from refineries to aircraft fuel supply systems.
  • Specifications include a maximum working pressure of 420 bar, operating temperature range of +5°C to +80°C, and memory capacity for 300 tests.
2. icountACM20 Z2 ATEX Approved Monitor:
  • Designed for explosive and hazardous areas, compliant with ATEX Directive 94/9/EC.
  • Features a stainless steel enclosure, ATEX approved handset and keypad, and compatibility with mineral oil and petroleum-based fluids.
  • Specifications similar to the ACM20, with additional safety features for hazardous environments.
3. icountPD Online Particle Detector:
  • Used for continuous monitoring of particle contamination in fuels.
  • Detects solid particle contamination with features like automatic light sensors and moisture sensor readings.
  • Operates within a flow range of 40-140 ml/min and supports a viscosity range of 1-500 cSt.
  • Certified for use in explosive and hazardous areas (ATEX Zone 2).
4. icountBS Bottle Sampler:
  • Typically used for sampling and analyzing fuel contamination in laboratory settings.
Procedures and Communication:
  • The icountPD performs a self-diagnostic check upon startup and can be configured using the icountPD Setup Utility or Microsoft Windows HyperTerminal.
  • Supports RS232 communication with specific settings and can integrate with PC/PLC systems.
Moisture Sensor and Flow Control:
  • An optional moisture sensor reports fluid saturation levels from 5% to 100%.
  • An auxiliary flow control device extends operational range, compensating for pressure and viscosity changes.
Calibration and Performance:
  • Calibrated using recognized online methods with a recommended interval of 24 months.
  • Offers reproducibility better than 1 ISO code and operates within a temperature range of -30°C to +60°C.
Ordering Information:
  • Various configurations available for different fluid types, calibration standards, display types, and communication interfaces.
Company Background:
  • Parker Hannifin Corporation is a global leader in motion and control technologies, emphasizing engineering excellence and customer service.
Conclusion: Parker Hannifin's icount series offers advanced solutions for monitoring fuel contamination, ensuring compliance with industry standards and enhancing safety in aviation fuel handling and storage.
Contact Information:
Provides contact details for Parker Hannifin Corporation offices worldwide, including phone numbers and email addresses for various countries.
European Product Information Centre:
A free phone number is provided for European countries.
Bulletin Information:
Identified as Bulletin FDCB417UK, dated May 2010, and © 2009 Parker Hannifin Corporation.
See more

Catalog excerpts

Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-1

icount Particle Monitoring ACM20, ACM20 Z2, IPD and IBS Aviation fuel + hazardous zones monitoring

 Open the catalog to page 1
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-3

A unique product with pedigree DEFSTAN 91-91 Issue 6 Jet A-1Fuel Specification, adopts particle counting. Development work carried out by the CMC engineers, in conjunction with Exxon Mobil Aviation, highlighted the need for an alternative test method to determine the levels of dispersed contamination in Jet fuel. 5 years of field testing and development of the already established and successful icountLCM20 Hydraulic Laser Particle Counter saw the introduction of the Parker icountACM20 with enhanced software providing the user with a better understanding of the contamination present in a sample....

 Open the catalog to page 3
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-4

The Parker icountACM20 Portable Particle Counter has been developed from existing technology for monitoring contamination in AvTur and other hydrocarbon fuels, in accordance with the Energy Institute (EI) Method IP 564. In addition, the ACM can also be used to monitor various fuels from existing sampling points in locations from refineries, pipelines, distribution terminals, airport fuel supply systems all the way through to the point of uplift into aircraft*. * Hot works permit required for online sampling (ATEX Zone 2 unit available). Page 14. • Fuel Testing Laboratories – DEFSTAN 91-91 Issue...

 Open the catalog to page 4
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-5

397 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. icountACM20 - rear view Construction: ABS structural foam and injection moulded case Hand-held display - ABS Keypad flurosilicone rubber Mechanical Components: Brass, plated steel, stainless steel and aluminium Seals: Fluorocarbon Hoses: Nylon (Kevlar braided microbore). St. steel armoured ends Flow Rate: 25 - 28ml/min (dictated by CMP) 100ml/min with additional flush button Fluid Compatability: Hydrocarbon Fuel, Mineral Oil. For other fluids consult Parker Fuse: 1.25 amp fast blow fuse included for overload protection (spare supplied)...

 Open the catalog to page 5
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-6

398 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. DEFSTAN 91-91 Issue 6 Defence Standard 91-91 is the specification for aviation turbine fuel, which the United Kingdom Civil Aviation Authority (CAA) has agreed is under the technical authority of the Director of the Defence Fuels Group. IP 564 Laboratory determination of the level of dispersed contamination in aviation kerosene using an Automatic Particle Counter (APC). This standard describes a method for determining the level of dispersed contamination in aviation kerosene fuels, specifically dirt particles and water droplets in...

 Open the catalog to page 6
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-7

For use in explosive and hazardous areas icountACM20 Z2 is designed to be used to monitor various fuels from existing sampling points in hazardous locations such as refineries, pipelines, distribution terminals, airport fuel supply systems all the way through to the point of uplift into aircraft. With Zone 2 classification, the icount ACM20 Z2 is the worlds only ATEX approved particle counter. Product Features: • Assembled in an approved and certified stainless steel enclosure to comply with ATEX Directive 94/9/EC. • Can be used in explosive and hazardous areas, including offshore and mining...

 Open the catalog to page 7
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-8

402 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. icountACM20 Z2 ATEX Approved Portable Particle Counter Features & Benefits Test Time: 2 minutes. Repeat Test Time: Every 2 minutes (Manual testing) Every 6 minutes (Automatic). Principle of Operation: Optical scanning analysis and measurement of actual particles and inference to water presence. Primary Output: 4ì(c), 6ì(c), 14ì(c), 21ì(c), 25ì(c), 30ì(c) counts per ml. Secondary Diagnostic Output: % Volume Distribution, via graphical display on handset. International codes: ISO 7-22 in accordance with ISO 4406-1999 Data entry: 32...

 Open the catalog to page 8
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-9

Specification Using icountACM20 Z2 Construction: Unit: Stainless Steel Carrying case: ABS Hand-held display: ABS Keypad: polyester membrane Mechanical components: Brass, plated steel, stainless steel and aluminium Seals: Fluorocarbon Hoses: Nylon (Kevlar braided microbore) Fluid compatibility: All fuels. For other fluids consult Parker Internal rechargeable battery: Note: ONLY to be charged outside of the hazardous area, with the unit switched off Fuse: 1.25A fast blow fuse included for overload protection Return to Parker Hannifin if fuse is blown icountACM20 2032 technology: Unique optical...

 Open the catalog to page 9
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-10

Installation Details icountACM20 Z2 ATEX Approved Portable Particle Counter Product number Supersedes Description icountACM20 Z2 + online kit & UK battery charger icountACM20 Z2 + online kit & US battery charger icountACM20 Z2 + online kit & Euro battery charger icountACM20 Z2 + online & lab kit + UK battery charger icountACM20 Z2 + online & lab kit + US battery charger icountACM20 Z2 + online & lab kit + Euro battery charger UK battery charger US battery charger Euro battery charger 2m process cable assembly Parsmart downloader software Carry case Bottle assembly Throttle kit Millipore adaptor...

 Open the catalog to page 10
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-11

405 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. Applications in hydraulics Solutions in the offshore industry. In addition, the icountACM20 Z2 can be used in many hydraulic system applications as detailed below. In many industries, worker awareness needs to be maintained at a high level to ensure the safety of their operation. This is particularly relevant to offshore oil-drilling and gas-drilling crews, given the interactive and hazardous nature of their work. The Zone II ACM portable particle analyser is a tried and tested technology designed, proven and approved as a fluid...

 Open the catalog to page 11
Icount Condition Monitoring Product Catalogue. IPD, ACM20, ACM20 Z2 and icountBS-12

406 Parker Hannifin Hydraulic Filter Division Europe FDHB500UK. icountACM20 Z2 ATEX Approved Portable Particle Counter Average Particle Counts in AV System The table below gives estimated counts found in a typical aviation fuel distribution system, and is given as guidance, in which API/EI filtration equipment is installed. Receipt into Microfilter Expect 2,500 counts per ml or cleaner @ 4ì(c) Receipt into Microfilter 4ì(c) 6ì(c) 14ì(c) ISO Code - 4406 1999 High Count 2,500 350 10 High Count Code 18 15 10 MF Receipt into FWS (After MF) 4ì(c) 6ì(c) 14ì(c) ISO Code - 4406 1999 High Count 500 50...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.