Condition Monitoring Products & Custom Solutions ENGINEERING YOUR SUCCESS.
Open the catalog to page 1The Parker Hannifin Filtration Group assures: Hydraulic, Lubrication & Coolant Filtration High-performance filtration systems for production machinery in industrial, mobile and military/marine. Consistent quality Technical innovation Premier customer service Parker’s technical resources provide the right filtration technologies that conform to your requirements. That’s why thousands of manufacturers and equipment users around the world rely on Parker Filtration products and people. Complete line of compressed air/gas filtration products; coalescing, particulate and adsorption filters in many...
Open the catalog to page 2Introduction Parker Hannifin is comprised of eight global groups: Aerospace, Climate & Industrial Controls, Fluid Connectors, Seal, Hydraulics, Filtration, Automation and Instrumentation. The Filtration Group consists of ten technical sales and service locations: Finite Filter, Hydraulic Filter Division North America, Hydraulic Filter Division Europe (two locations), Process Filter, Racor, Parker Hannifin Brazil and Parker Hannifin Korea. Quality Is Top Priority Parker Filtration has had a total quality management system in place for years, as well as a Director of Corporate Quality for all of Parker....
Open the catalog to page 4icountLCM20 Fluid Condition Monitoring Portable Particle Counter A portable particle counter designed to be used in the field icountLCM20 is a proven answer to fluid system contamination monitoring. Multi-standard ISO and NAS cleanliness reporting, data entry, data graphing and integral printing are all standard on this world proven contamination monitor. Product Features • icountLCM20 is a proven answer to fluid system contamination monitoring. • 2-minute test procedure. • Multi-standard ISO, NAS and AS4059 cleanliness reporting. • Data entry, data graphing and integral printer. • 6,000 PSI...
Open the catalog to page 5Test time: Particle counts: International codes: Data retrieval: Max. working pressure: Max. flow rate: Working conditions: Computer compatibility: 2 minutes MTD 4+, 6+, 14+, 21+, 38+ and 70+ microns(c) ACFTD 2+, 5+, 15+, 25+, 50+ and 100+ microns ISO 7-22, NAS 0-12 Memory access gives test search facility 6000 psi (420 bar) 106 GPM when used with system 20 Sensors. Higher with single point sampler LCM will operate with the system working normally Interface via RS232 connection @ 9600 baud rate. • Data entry allows individual equipment test log details to be recorded. • Data retrieval of test...
Open the catalog to page 6icountLCM20 Specifications Automatic Particle Counters (APC), have been widely used for many years in condition monitoring of hydraulic fluids. However, it is only recently that APCs have become flexible enough to enable the instruments to be taken out of the laboratory and used on-line in order to obtain the most credible form of results. Unusually, the move from fixed laboratory use, to portable field use has not been at the expense of accuracy or user flexibility, but has actually enabled the instruments to be used over a wider range of applications and situations. The most common monitoring...
Open the catalog to page 7*Note: In compliance with international standards, all Parker portable particle counters can meet the ISO Medium test dust standards. The icountLCM’s, in addition to the complete range of Condition Monitoring products, are capable of achieving certification to ISO 4406:1999 and with traceability to ISO 11171 for SRM 2806, via ISO 11943. Accessory Kit for icountLCM Classic
Open the catalog to page 8• Certification of fluid cleanliness levels. • Early warning instrument to help prevent catastrophic failure in critical systems. • Immediate results with laboratory accuracy. • To comply with customer cleanliness requirements and specifications. • New equipment warranty compliance. • New oil cleanliness testing. Data Download Management Dedicated software, provides the link between an icountLCM20 and your computer management system. 16-column printer for hard copy data. A feature of the icountLCM is the on-board printout data graphing option developed to support predictive maintenance procedures....
Open the catalog to page 9icountLCM20 Portable Particle Counter Introducing the new icountLCM ‘Classic’ There is a new addition to the proven range - the aa^fc teountixiM20 icountLCM ‘Classic’. Only available from Parker, the ‘Classic’ retains all the technology that made the icountLCM one of the most accurate, reliable and popular portable particle counters available. Our design engineers have re-configured the icountLCM specification in a way that has reduced our manufacturing costs. These savings have been passed onto icountLCM ‘Classic’ customers. How have we done this? Parker listened to our existing customers and...
Open the catalog to page 10icountACM20Aviation Fuel Contamination Monitoring DEFSTAN 91-91 Issue 6 Jet A-1Fuel Specification, adopts particle counting. The first fully functional particle counter approved for use on aviation fuel. After 5 years of development work carried out by Parker UK and partner, the ACM20 has passed all technical barriers and is now approved for aviation fuel quality per DEFSTAN 91-91 Issue 6. Parker has consistently provided technically superior products to all fluid conditioning applications. Product Features • icountACM20 monitors aviation fuel contamination to DEFSTAN 91-91 Issue 6 Jet A-1 fuel...
Open the catalog to page 11Test Time: 2 minutes Repeat Test Time: Every 2 minutes (Manual testing), every 6 minutes (automatic) Principle of Operation: Optical scanning analysis and measurement of actual particles and inference to water presence Primary Output: >4g(c), >6g(c), >14g(c), >21g(c), >25g(c), >30p(c) counts per ml Secondary Diagnostic Output: % Volume Distribution, via graphical display on handset and printout (printout not available on icountACM20Z) International codes: ISO 7-22 in accordance with ISO 4406-1999 Data entry: 32 character two line dot matrix LCD. Full alpha numeric entry facility on keypad Data...