video corpo

Condition Monitoring

Condition Monitoring
1 / 80 PagesView full catalog

Condition Monitoring

Product catalog summary
Introduction
Parker Filtration specializes in advanced filtration technologies aimed at energy conservation and pollution control across various industries. Their products are designed to improve system efficiency, minimize downtime, and facilitate predictive maintenance.
Product Offerings
  • Hydraulic, Lubrication & Coolant Filtration: High-performance systems for industrial, mobile, and military applications.
  • Compressed Air & Gas Filtration: A comprehensive range of filters for diverse industries.
  • Process & Chemical Fluid Filtration: Systems for beverage, chemical, and food processing.
  • Racor Fuel Conditioning & Filtration: Engine protection systems for various environments.
  • System Contamination Monitoring: Solutions for dynamic particle and fluid analysis.
Condition Monitoring Products
Parker offers a range of condition monitoring products, including the LaserCM Contamination Monitor and Icount PD Particle Detector, providing accurate filtration efficiency and system cleanliness indications.
LaserCM Portable Particle Counter
The LaserCM is a portable particle counter using microprocessor-controlled optical scanning for precise contaminant measurement. Key features include a 2-minute test time, compatibility with international codes, data retrieval capabilities, and a portable design.
Ordering Information
Parker has standardized its part numbering system to simplify product ordering, featuring a product configurator and cross-references to previous part numbers.
Conclusion
Parker Filtration's products and solutions cater to the diverse needs of equipment manufacturers and end-users, offering reliable and efficient filtration and monitoring solutions across various industries.
Specifications and Standards
The LaserCM is equipped with a stainless steel armoured hose, rechargeable battery pack, and a fast blow fuse. It supports micron channel analysis and includes a 3v character dot matrix LCD. The device is calibrated to ISO standards and is CSA certified.
Operation
The device is user-friendly, requiring only a start button press and a dial turn to initiate the test, suitable for monitoring corrosive fluids like phosphate ester-based lubricants.
Data Management
The Datum software links the LaserCM with computer management systems, offering features like graphic output and trend analysis.
Product Variants
The LCM 'Classic' is a cost-effective version of the LaserCM, available in various configurations.
Sampling Solutions
Offline and online sampling solutions, including the Universal Bottle Sampler, are designed for efficient fluid sampling and testing.
Applications and Benefits
The LaserCM provides immediate results with laboratory accuracy, aiding in early detection of potential system failures.
System 20 Features & Benefits
Suitable for drilling equipment, mining, and industrial hydraulics, System 20 provides accurate readings of flow, pressure, and temperature without system shutdown.
Monitors
Includes analogue and electronic monitors, offering digital display and data download capability.
Autoremote Particle Counter MCM20
Used in test rigs and industrial plants, featuring continuous particle counting and PC/PLC control.
Icount Particle Detector (IcountPD)
Designed for fluid condition monitoring, it uses laser diode optical detection and offers independent monitoring of system contamination trends.
H2Oil - Water in Oil Monitor and Moisture Sensor Range
These devices ensure effective oil maintenance and moisture detection in hydraulic and lubricating systems.
Pressure Transducers and Transmitters
The ASIC 'Performer' range offers pressure sensors for industrial applications, providing voltage or current signal outputs.
Aviation Fuel Contamination Monitoring
The ACM20 Lab Unit is a portable particle counter for monitoring contamination in aviation fuel.
Conclusion
The document serves as a comprehensive guide for selecting and using Parker Hannifin's fluid condition monitoring products, ensuring optimal performance and compatibility with various industrial applications.
See more

Catalog excerpts

Condition Monitoring-1

Fluid Condition Monitoring and Fuel Hydrocarbon Monitoring Solutions

 Open the catalog to page 1
Condition Monitoring-2

• Consistent quality • Technical innovation • Premier customer service Parkers technical resources provide the correct filtration technologies that conform to your requirements. That’s why thousands of manufacturers and equipment users around the world rely on Parker Filtration products and people. Worldwide Sales and Service Parker Filtration’s global reputation as a reliable supplier of superior filtration products is the result of a focused and integrated development and manufacturing system. Parker Filtration consolidates quality filtration products, manufactured by process filtration, air...

 Open the catalog to page 2
Condition Monitoring-3

Condition Monitoring Products Contents Fluid Condition Monitoring and Contamination Control 1 LaserCM Contamination Monitor 3 cniversal Bottle Sampler ww Single Point Sampler wk System vx Sensors and Monitors vw MCMvx Autoremote Monitor vk Icount PD Particle Detector 3w HvOil – Water in Oil Monitor 41 Moisture Sensor Range 45 Oilcheck Monitor m3 Fluid condition monitoring Asic ‘Performer’ mk Transducers & transmitters Parker Hannifin Hydraulic Filter Division Europe FDCB3kmct. Introduction Working with equipment manufacturers, hydraulic system designers and maintenance engineers, one of the key...

 Open the catalog to page 3
Condition Monitoring-4

Condition Monitoring Products Important changes to our product ordering information Standard Product Tables and a Product Configurator Parker Hannifin Hydraulic Filter Division Europe FDCB3kmct. v Parker Filtration has recently undertaken a review of its part numbering with a view to standardising on a common part number style for all Filtration products. As a result of the many acquisitions we have made over the past wx years, it became clear to us that there was a need to standardise on a clear format for our part numbers. Accordingly, in this new catalogue, you will find the new part number...

 Open the catalog to page 4
Condition Monitoring-5

Portable Particle Counter LaserCM Fluid Condition Monitoring Fluid condition monitoring 3

 Open the catalog to page 5
Condition Monitoring-6

Portable Particle Counter LaserCM Features & Benefits Test time: v minutes Particle counts: vz, mz, wmz, vmz, mxz and wxxz microns nz, lz, wnz, vwz, 3jz and kxz microns(c) International codes: ISO k-vv, NAS x-wv Data retrieval: Memory access gives test search facility Max. working pressure: nvx bar Max. flow rate: nxx I/min when used with system vx Sensors. Higher with single point sampler (consult Parker) Working conditions: LaserCM will operate with the system working normally Computer compatibility: Interface via RSv3v connection Y ilxx baud rate. Special ‘diagnostics’ are incorporated into...

 Open the catalog to page 6
Condition Monitoring-7

Fluid condition monitoring 5 Specification Automatic Particle Counters (APC’s), have been widely used for many years in condition monitoring of hydraulic fluids. However, it is only recently that APC’s have become flexible enough to enable the instruments to be taken out of the laboratory and used on-line in order to obtain the most credible form of results. cnusually, the move from fixed laboratory use, to portable field use has not been at the expense of accuracy or user flexibility, but has actually enabled the instruments to be used over a wider range of applications and situations. The most...

 Open the catalog to page 7
Condition Monitoring-8

Description Lexan, structural foam and ABS case ABS handheld display Mechanical composition Z Brass, plated steel, stainless steel and aluminium Fluorocarbon seals Perfluoroelastomer seals Nylon hoses (kevlar braided microbore) Stainless steel armoured hose ends w.vm fluid connection hose Rechargeable battery pack wvbdc power supply Fast blow fuse cnique optical scanning system Bonded glass optical window enclosed in SS plate Micron channels analysis (Six) Analysis range ISO k to vv incl. (NAS x to wv) 3v character dot matrix LCD. Alpha numeric keypad Data retrieval Calibration to ISO standards*...

 Open the catalog to page 8
Condition Monitoring-9

Fluid condition monitoring Operation k Operating the Parker LaserCM is as simple as pressing the start button and turning the dial. The test procedure is automatic and in the case of the LaserCM takes no more than v minutes to complete. LaserCM makes the difference in industry Fully accredited to BS EN lxjvm:wiiv and IEC lxjvm-w (safety of laser products) Standards, accredited to cSA Standards and achieving full ISO certification. LaserCM offers users advanced laser technology, a fast, dynamic and on-line v minute system test cycle. A LaserCM Aggressive Fluids model is also available, suitable...

 Open the catalog to page 9
Condition Monitoring-10

Portable Particle Counter LaserCM Why On-Site Fluid Contamination Monitoring? Datum Data Management Certification of fluid cleanliness levels. Early warning instrument to help prevent catastrophic failure in critical systems. Immediate results with laboratory accuracy. To comply with customer cleanliness requirements and specifications. New equipment warranty compliance. New oil cleanliness testing. Parker Hannifin Hydraulic Filter Division Europe FDCB3kmct. Section w 8 Laser CM Test ON LINE TEST TEST NcMBER xvv D M Y Date xn-x3-xl Time wm-mv ISO: vx/wm/xi Count / wxxml [n| (c) jvxkvw [l| (c)...

 Open the catalog to page 10
Condition Monitoring-11

Fluid condition monitoring Ordering Information (LaserCM and ‘Classic’ LaserCM) Introducing the new LCM ‘Classic’ i There is a new addition to the proven range Z the LCM ‘Classic’. Only available from Parker, the ‘Classic’ retains all the technology that made the LaserCM one of the most accurate, reliable and popular portable particle counters available. Our design engineers have re-configured the LaserCM specification in a way that has reduced our manufacturing costs. These savings have been passed onto LCM ‘Classic’ customers. How have we done this? First we talked to our existing customers...

 Open the catalog to page 11
Condition Monitoring-12

Parker Hannifin Hydraulic Filter Division Europe FDCB3kmct. wx Notes

 Open the catalog to page 12
Condition Monitoring-13

Offline Sampling Universal Bottle Sampler Fluid condition monitoring 11

 Open the catalog to page 13
Condition Monitoring-14

Offline Sampling Universal Bottle Sampler wv Typical Applications Batch sampling Aircraft rig certification Oil research Laboratory testing Transfer line monitoring Features & Benefits Simple operation Efficient testing procedure Clean and contamination free sampling Available for both mineral based and aggressive fluids Further advances the LCMvx’s flexibility into laboratory bottle sampling environments Can accept various different sized bottles Minimal working parts Internal auto setting fuse for overload protection Simple maintenance procedures Providing The Dynamic Link To All Portable Particle...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.