Catalog excerpts
12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 12CS Series features a Parker, replaceable coreless Ecoglass lll element in a re-usable bowl for easy used element removal and disposal. Maximum pressure 35 bar and the Ecoglass element offers a low environmental impact in landfills. Parker Hannifin Hydraulic Filter Division Europe European Product Information Centre Freephone: 00800 27 27 5374 (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com • 12CS features a Parker quality, replaceable coreless Ecoglass lll element. • Re-usable bowl design for easy element removal. • Maximum pressure 35 bar. • An eco filter solution for hydraulic systems. Parker Hannifin Hydraulic Filter Division Europe FDHB500UK/12CS
Open the catalog to page 1gallons of discarded residual Waste oil. The Smart Alternative to Spin-on Cans! Features: Parker engineers have developed an innovative alternative to the age old spin-on style can. This new design provides all of the benefits of high efficiency, long life Ecoglass III filtration, without the environmental impact. The new environmentally-friendly 12CS hydraulic filters feature a reuseable bowl and a quality filter element constructed primarily of nylon and fiberglass. The element core is permanently attached as part of the filter bowl. When replaced, the element reduces costs, eliminates...
Open the catalog to page 2Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 35 bar (500 psi) Fatigue: 27.6 bar (400 psi) 1,000,000 cycles: 27.6 bar Design Safety Factor: 2.5:1 Operating Temperatures: Buna: -40°C to 107°C Element Collapse Rating: 10.3 bar (150 psid) Element Condition Indicators: For predictive maintenance, 3 types of indicator are available: An electrical analogue or switch type indicator or a battery operated visual LED indicator. 12CS-2 MINIMUM ELEMENT REMOVAL CLEARANCE Drawings are for reference only. Contact factory for current version. Port Option Parker Hannifin Hydraulic Filter...
Open the catalog to page 3Coreless Spin-on Filters 12CS Series Beta Rating Capacity grams Results typical from Multi-pass tests run per test standard ISO 16889 @ 15 gpm to 50 psid terminal - 10 mg/L BUGL Refer to Appendix for relationship to test standard ISO 4572. Flow vs Pressure Loss Empty Housing Parker Hannifin Hydraulic Filter Division Europe FDHB500UK/12CS FDHB500UK.
Open the catalog to page 4Parts List Service Instructions 12CSFilter Service Index Head Filter element should be replaced as indicated by filter indicator gauge,or at specified service intervals recommended by the OEM. Replacement element procedure A. Shut down system and release pressure in the filter line. B. Loosen bowl and remove rotating counter clockwise. C. Remove dirty element from filter head and discard. D. Lubricate element seals on clean element and install on filter head element locator. E. Install reuseable bowl onto element and filter head. Electrical Switch or Analog Sensor Element Condition...
Open the catalog to page 5Coreless Spin-on Filters 12CS Series How To Order Select the desired symbol (in the correct position) to construct a model code. Example: BOX 1: Basic Assembly Symbol Description Coreless Spin-On, 75 l/min nominal G¾" BSPP (ISO 220) integral threads BOX 3: Element Media Symbol Description *Porting recommended for best delivery. Consult Parker for additional seal options Replacement Elements (Ecoglass) Filter Model - Nitrile seals Media Parker Hannifin Hydraulic Filter Division Europe FDHB500UK/12CS FDHB500U