Group: Parker
Catalog excerpts
Axial Piston Pumps Series eP2/eP3 - Electronic Controls Variable Displacement
Open the catalog to page 1Axial Piston Pumps Series eP2/eP3 - Electronic Controls Parker Hannifin Pump & Motor Division Europe Chemnitz, Germany
Open the catalog to page 2Axial Piston Pumps Series eP2/eP3 - Electronic Controls General Information Introduction Parker’s P2 / P3 series has been designed to meet the specific demands of heavy duty mobile applications throughout the following markets: – Material Handling Equipment (e.g Reachstacker, HD Lift Trucks, AT Cranes) – Construction Equipment (e.g. Articulated Dump Trucks, Wheel Loaders) – Mining and Drilling (e.g. Dump Trucks, Drill Rigs) – Forestry Equipment (e.g. Forwarder, Harvester) By featuring an optimized envelope and a unique port layout the product line provides for a cost saving direct mount on...
Open the catalog to page 3Axial Piston Pumps Series eP2/eP3 - Electronic Controls Ordering Code P Axial piston pump, variable displacement Code P2 P3 Pump Series standard supercharged Shaft Type SAE B-B Spline SAE C Spline SAE C-C Spline SAE C Spline (w/o undercut) SAE D Spline SAE D Spline (w/o undercut) DIN 5480 Spline, W50 Paint Option no paint Parker black primer no paint Parker black primer Multiple Pump Option shipped as individual pump Port Location and Threads Side ports, UNC threads Side ports, metric threads Side ports, UNC threads Side ports, metric threads Mounting Flange Control Option (failsafe option)...
Open the catalog to page 4Electronic Control Options Axial Piston Pumps Series eP2/eP3 - Electronic Controls Electronic Displacement Controls EC and EF Closed loop working principle: Electronically displacement controlled eP2 / eP3 provides an output flow defined by a displacement input command and maintains its swash angle (and thereby output flow level) until a new displacement command is received. Under static displacement control conditions - i.e. as long as actual pump displacement (actual value) corresponds to displacement command (nominal value) - the control spool of the pump‘s control valve is held at...
Open the catalog to page 5Axial Piston Pumps Series eP2/eP3 - Electronic Controls Electronic Control Options Control Functions and Options Control Schematics As an option eP2 / eP3 can be equipped with a pressure sensor to either grant for pressure monitoring or to realize electronic pressure limitation. Pressure limitation function as well as secondary control options such as variable input torque limitation and speed compensation / flow control require the usage of a Parker supplied Pump Control Module (PCM). PCM command inputs can be both analog (0..5V) or CAN (J1939). Displacement control w/o Parker supplied PCM...
Open the catalog to page 6Axial Piston Pumps Series eP2/eP3 - Electronic Controls Electronic Control Options Displacement control with optional pressure limitation (main: D / DP) w/ Parker supplied PCM w/ Pressure sensor • Optional torque limitation (secondary: T) • Optional speed compensation / flow control (secondary: S) • External speed sensor (not pump mounted, outside scope of supply) or CAN speed feedback required for speed compensation Displacement control (main: D) w/ Parker supplied PCM Example: 0% default setting (EC), standard valve position P P Example: 0% default setting (EC), standard valve position...
Open the catalog to page 7Electronic Control Options Axial Piston Pumps Series eP2/eP3 - Electronic Controls Technical Data Proportional control valve General Model Design Connector Mating connector Protection class Wiring recommendation Parker D1FB series Direct operated proportional DC valve (4/2 design) Deutsch DT04-2P Deutsch DT06-2S IP 67 in accordance with EN 60529 (with correctly installed and mounted mating connector) Stranded wire cable, min. 0.75 mm² (AWG 18) Electrical characteristics Supply voltage Current consumption Nominal resistance (at 20 °C) Recommended dither frequency Recommended dither amplitude...
Open the catalog to page 8Electronic Control Options Axial Piston Pumps Series eP2/eP3 - Electronic Controls Pump Control Module - PCM Ordering Code 1450039 • • • • • Task oriented controller with eP2 / eP3 specific firmware Covers all primary and secondary control functions (see page 6) Can be operated as both stand alone module (analog inputs) or CAN module (J1939) High reliability connectors system for harsh mobile environment CE certified Technical Data General Model Design Weight Temperature range Protection class Connector Parker PCM IQAN task oriented controller with pump specific firmware 350 g [-40…+85]°C...
Open the catalog to page 9Axial Piston Pumps Series eP2/eP3 - Electronic Controls Pump shown is a CW rotation eP2075 with proportional control valve and swash angle sensor. Dimensions for EC and EF control option are identical. CCW pump will have inlet and outlet gage port on opposite side of rear cover. If required by installation the control valve and the swashangle sensor can be positioned at opposite side of the pump. Please consult manufacturer for details. Outlet gage port thread see table SAE-C 2 bolt mounting flange 2 places Ø17.58 SAE-C 4 bolt mounting flange Ø14.35 drain port thread see table Inlet gage...
Open the catalog to page 10Axial Piston Pumps Series eP2/eP3 - Electronic Controls Lifting hook (3/8-16 UN-2B thread) 115 Thread size see table Outlet port 1" 4-bolt flange standard pressure series (code 62) Ripple chamber plug Do not remove! 51 77 81 Optional drain port 195 204.7 Dimensions will be reversed on a CCW pump "Weep hole" both sides seal option D,Q and T Thread size see tabel Inlet port 2" 4-bolt flange standard pressure series (code 61) For thru drive dimensions and shaft information please check catalogue MSG30-2800/UK (Axial Piston Pumps – Series P2 / P3). 11 Parker Hannifin Pump & Motor Division...
Open the catalog to page 11Axial Piston Pumps Series eP2/eP3 - Electronic Controls eP2075 w/ pressure sensor Pump shown is a CW rotation eP2075 with proportional control valve, swash angle sensor and pressure sensor. Port option C (pump with UNC threads) Lifting hook (3/8-16 UN-2B thread) Thread size see table Outlet port 1" 4-bolt flange standard pressure series (code 62) Port option D (pump with metric threads) Lifting hook (3/8-16 UN-2B thread) Port & threads option Thread size see table Outlet port 1" 4-bolt flange standard pressure series (code 62) Drain port Inlet port Outlet port Inlet & outlet gage port...
Open the catalog to page 12All Parker Hannifin France SAS catalogs and technical brochures
-
MPI™ Medium Pressure Products
20 Pages
-
Needle Valves
48 Pages
-
Phastite® Tube Connectors
36 Pages
-
Quick Coupling Products
230 Pages
-
Ball and Plug Valves
72 Pages
-
Aluminium Roller Guides
20 Pages
-
OSPP-Classic
37 Pages
-
Valve Products Isys ISO Series
42 Pages
-
2A Pneumatic Cylinders
48 Pages
-
Stainless Steel Valves
72 Pages
-
Global FRL and P3Y Series
122 Pages
-
MMB Hydraulic Cylinders
24 Pages
-
PWO Water/oil cooler
12 Pages
-
QDC - Quiet DC Cooler
56 Pages
-
Air Oil Coolers
18 Pages
-
Hydraulic Valves Industrial Standard
817 Pages
-
Quick Couplings Catalog
185 Pages
-
Crankcase Ventilation
12 Pages
-
Condition Monitoring
72 Pages
-
Screw-Driven Positioners
111 Pages
-
Belt Driven Positioners
151 Pages
-
GVI Global Vehicle Inverter
16 Pages
-
GVM142 Global Vehicle Motor
16 Pages