video corpo cad

Air Oil Coolers
18Pages

{{requestButtons}}

Catalog excerpts

Air Oil Coolers - 1

Air Oil Coolers LAC with AC Motor for Industrial Use

Open the catalog to page 1
Air Oil Coolers - 2

CADE – Cylinder and Accumulator Division Europe Made in Europe - serving all markets and industries Parker CADE UK Sandycroft, (Chester) Parker CADE Sweden Falköping Parker CADE France Colombes Parker CADE Poland Wroclaw Parker CADE Italy Arsago & Turin Parker CADE Germany Cologne Our product range - click for more detail: Bladder Accumulators Piston Accumulators Parker Hannifin Diaphragm Accumulators Hydraulic Accumulator Pulsation Dampers Technology and Service Center Industrial Hydraulic Cylinders Mill-type Cylinders This is to certify that Kohler GmbH Accessories Air-Oil Cooler...

Open the catalog to page 2
Air Oil Coolers - 3

Air Oil Cooler Range As a global player specializing in innovative, efficient system solutions for temperature optimization and energy storage, Parker’s products are used for the most diverse environments and applications all over the world. In hydraulic systems energy is transformed and transmitted. During this process, efficiency losses occur, i.e. mechanical and hydraulic energy is converted into heat. It is the purpose of the cooler to dissipate this heat and to maintain the thermal balance of the hydraulic fluid. Parker’s high performance coolers are equipped with axial fans and IE3...

Open the catalog to page 3
Air Oil Coolers - 4

For industrial use – maximum cooling capacity 300 kW The LAC air oil cooler with single-phase or three-phase AC motor is optimized for use in the industrial sector. Together with a wide range of accessories, the LAC cooler is suitable for installation in most applications and environments. The maximum cooling capacity is 300 kW at ETD 40 °C. Parker’s Air Oil cooler range also includes the following versions: LAC-X ( ATEX version ) MAC ( Marine applications ). The LAC-X version is approved for applications where there may be an explosive environment above ground. The MAC is especially...

Open the catalog to page 4
Air Oil Coolers - 5

The Olaer Group has been part of Parker Hannifin since July 1st, 2012. With manufacturing and sales in 14 countries in North America, Asia and Europe, the Olaer Group expands Parker’s presence in geographic growth areas and offers expertise in hydraulic accumulator and cooling systems for target growth markets such as oil and gas, power generation and renewable energy. YOUR VALUE • Easy to maintain and easy to retrofit in many applications • Cooler matrix with low pressure drop and high cooling capacity • Clever design and the right choice of materials and components produce a long useful...

Open the catalog to page 5
Air Oil Coolers - 6

Calculate the Cooling Capacity Requirement Cooling capacity requirement? Installed capacity Flow? Pressure? Pump capacity? Measure in your existing unit Theoretical capacity losses ... suggested solution Parker Hannifin Cylinder and Accumulator Division Europe

Open the catalog to page 6
Air Oil Coolers - 7

Better energy consumption means not only less environmental impact, but also reduces operating costs, i.e. more cooling per € invested. with precise calculations and our engineers’ support Optimal sizing produces efficient cooling. Correct sizing requires knowledge and experience. Our calculation program, combined with our engineers’ support, gives you access to this very knowledge and experience. The result is more cooling per € invested. The user-friendly calculation program can be downloaded from www.parker.com/acde. Valuable system review into the bargain A more wide-ranging review of...

Open the catalog to page 7
Air Oil Coolers - 8

The cooling capacity curves are based on the inlet oil temperature and the ambient air temperature. An oil temperature of 60 °C and an air temperature of 20 °C produce a temperature difference of 40 °C. Multiply by kW/°C for total cooling capacity. Pressure drop Parker Hannifin Cylinder and Accumulator Division Europ

Open the catalog to page 8
Air Oil Coolers - 9

Catalogue MSG10-6001/UK Cooling capacity Cooling capacity kW/°C kW/°C 4.00 4.00 3.50 3.50 Cooling capacity Cooling capacity kW/°C kW/°C 0.80 0.80 50 50 Cooling capacity tolerance ± 10% kW. Parker Hannifin Cylinder and Accumulator Divis

Open the catalog to page 9
Air Oil Coolers - 10

Acoustic pressure level LpA dB(A) 1m* * = Noise level tolerance ± 3 dB(A). Parker Hannifin Cylinder and Accumulator Division Europe

Open the catalog to page 10
Air Oil Coolers - 11

OUTLET (With by-pass type S) Parker Hannifin Cylinder and Accumulator Divisio

Open the catalog to page 11
Air Oil Coolers - 12

Acoustics pressure level LpA dB(A) 1m* * = Noise level tolerance ± 3 dB(A) Parker Hannifin Cylinder and Accumulator Division Europe

Open the catalog to page 12
Air Oil Coolers - 13

Cooling capacity Pressure drop LAC 200 at 30 cSt (single-pass) Parker Hannifin Cylinder and Accumulator Division Europe

Open the catalog to page 13
Air Oil Coolers - 14

Cooler Size Number of Poles / Motor Thermo Contact Cooler Matrix Matrix Guard S: stone guard, D: dust guard, P: dust and stone guard Standard / Special Configure your product on

Open the catalog to page 14
Air Oil Coolers - 15

Technical Specifications Fluid Combinations Mineral Oil HL/HLP in accordance with DIN 515 HFA, HFB in accordance with CETOP RP 77H Water glycol HFC in accordance with CETOP RP 77H Phosphate ester HFD-R in accordance with CETOP RP 77H Material Cooler matrix Glass fibre reinforced polypropylene / Aluminium Other parts Surface treatment Electrostatically powder-coated Technical Data, Cooler Matrix Technical Data for 1-Phase Motor Maximum static operating pressure Insulation class Dynamic operating pressure Heat transfer limit Protection class Maximum oil inlet temperature Technical Data for...

Open the catalog to page 15
Air Oil Coolers - 16

With our specialist expertise, industry knowledge and advanced technology, we can offer a range of different solutions for coolers and accessories to meet your requirements. Take the Next Step - choose the right accessories Supplementing a hydraulic system with a cooler, cooler accessories and an accumulator gives you increased availability and a longer useful life, as well as lower service and repair costs. All applications and operating environments are unique. A wellplanned choice of the following accessories can thus further improve your hydraulic system. Please contact Parker Hannifin...

Open the catalog to page 16
Air Oil Coolers - 17

Fast Track Check out Parker’s Fast Track Programme includes many options for LAC coolers Accumulators and Coolers Distributor Catalogue Air Oil Cooler with AC Motor - LAC Series Suitable for most Industrial applications, the LAC air oil cooler series offers an efficient and robust design and is available in a range of cooling capacities from 1 kW to 300 kW. Part Number For industrial applications Cooling capacity up to 300 kW Robust construction Low service and maintenance Wide variety of specifications For the complete product range see: www.parker.com Parker Hannifin Cylinder and...

Open the catalog to page 17

All Parker Hannifin France SAS catalogs and technical brochures

  1. Needle Valves

    48 Pages

  2. OSPP-Classic

    37 Pages