Catalog excerpts
Explosion Proof Servo Motors
Open the catalog to page 1WARNING — USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. • This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. • The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and...
Open the catalog to page 2Explosion Proof Servo Motor Standards Hazardous Areas Classification6 Compliance with North American Standards7 Operating category and marking of EY servomotors8 Operating category and marking of EX servomotors9 Explosion Proof Motor for Zone 2 - EY Series Overview11 EY Servo Motors - CE Marked for Explosive Atmospheres12 Drive Associations14 Dimensions16 Order Code17 Explosion Proof Motor for Zone 1 - EX Series Overview19 EX Servo Motors - CE Marked for Explosive Atmospheres20 Drive Associations22 Dimensions (Resolver Version)
Open the catalog to page 3Parker Hannifin The global leader in motion and control technologies A world class player on a local stage Global Product Design Parker Hannifin has more than 40 years experience in the design and manufacturing of drives, controls, motors and mechanical products. With dedicated global product development teams, Parker draws on industry-leading technological leadership and experience from engineering teams in Europe, North America and Asia. Local Application Expertise Parker has local engineering resources committed to adapting and applying our current products and technologies to best fit...
Open the catalog to page 4Explosion Proof Servo Motor ATEX/IECEx, KOSHA Max Speed Ingress protection level Power Supply UL 674 standard: Electric Motors and Generators for use in Division 1 Hazardous (Classified) Locations
Open the catalog to page 5Explosion Proof Servo Motor Hazardous Areas Classification Standards Hazardous Areas Classification Dangerous Areas Identification European directive 99/92/EC makes explicit the responsibility of employers to protect employees who may be exposed to risk of ATEX environments (Explosive Atmosphere). The employer must assess the risk and classify potentially dangerous areas. Equipment and materials must also be suited for use in dangerous areas in accordance with ATEX directive 2014/34/EU. EX Series Hazard Definition Permanent Explosive atmospheres present continuously, for long periods or...
Open the catalog to page 6Explosion Proof Servo Motor Compliance with North American Standards Compliance with North American Standards EX servomotors are CLASS 1, division 1, Groups C and D, explosion-proof apparatus designed to operate in explosive atmospheres in accordance with standard UL674 and UL1004 for electrical parts. Marking in accordance with Standard UL674 Class I Explosive Class I Gas, atmospheres vapour and liquids can exist all the time or some of the time under Class II Dust normal operating conditions Class III Fibers Suitable for Parker UL servomotors Compliance with China Standards Marking...
Open the catalog to page 7Explosion Proof Servo Motor Operating category and marking of EY servomotors Operating category and marking of EY servomotors ATEX gazeous atmospheres II 3 G Ex nA IIC T3 Gc IP65 II nA nC Equipment with protection against sparks M2 High level of protection M1 Very high level of protection nR Equipment with restricted breathing 1 Very high level of protection 2 High level of protection nA Equipment II Surface not generating sparks 3 Normal level of protection Mb High level of protection Ga Very high level of protection Ma Very high level of protection Protection against explosions Gb High...
Open the catalog to page 8Explosion Proof Servo Motor Operating category and marking of EX servomotors Operating category and marking of EX servomotors ATEX/IECEx gazeous atmospheres II2 G Ex db IIB T4 Gb IP64 – Group IIA or IIB – category 2G– zone 1 and 2. II Ga Very high level of protection Mb High level of protection 2 High level of protection Ma Very high level of protection Protection against explosions Gb High level of protection 1 Very high level of protection M2 High level of protection M1 Very high level of protection 3 Normal level of protection Gc Normal level of protection * Maximum surface temperature...
Open the catalog to page 9Explosion Proof Servo Motor - EY Series www.parker.com/eme/ey Explosion Proof Motor for Zone 2 - EY Series Overview Description The EY series is a range of permanent magnet explosion-proof brushless servo motors designed for use in explosive atmospheres in zone 2 for gas and dust at 40°C or 60°C ambient temperature. The EY series of servo motors are characterized by excellent motion quality, dynamic acceleration/deceleration capabilities and high torque output over a wide speed range. Various winding variants and numerous options are available to offer maximum flexibility. This range is in...
Open the catalog to page 11Explosion Proof Servo Motor - EY Series Technical Data EY Servo Motors - CE Marked for Explosive Atmospheres Technical Data Peak Torque Rated Power Rated Torque 230 VAC power supply - single or three-phased Rated Speed Peak Torque M peak Peak Current I peak
Open the catalog to page 12Explosion Proof Servo Motor - EY Series Technical Data 400 VAC power supply - three-phased Rated Torque Mn Peak Torque M peak Peak Current I peak
Open the catalog to page 13Explosion Proof Servo Motor - EY Series Drive Associations Drive Associations 230 VAC power supply Motor Associated Drive Sizes(1) Compax3 SLVD‑N With 40°C ambiant temperature - 230 VAC power supply EY310EAP With 60°C ambiant temperature - 230 VAC power supply EY310EAP
Open the catalog to page 14Explosion Proof Servo Motor - EY Series Drive Associations 400 VAC power supply Motor With 40°C ambiant temperature - 400 VAC power supply EY310EAP With 60°C ambiant temperature - 400 VAC power supply EY310EAP
Open the catalog to page 15Explosion Proof Servo Motor - EY Series Dimensions Shaft diameter x length Mounting Flange centering / interaxis hole [mm] Without Brake With Brake
Open the catalog to page 16All Parker Electromechanical and Drives Division Europ catalogs and technical brochures
-
AC15 Variable Speed Drive
16 Pages
-
Belt Driven
32 Pages
-
SensoNODETM
2 Pages
-
Medical solutions
2 Pages
-
RS and AXEM Series
14 Pages
-
DC590P
28 Pages
-
AC890
25 Pages
-
HPLA Linear Actuators
40 Pages
-
AC10 Variable Speed Drive
26 Pages
-
AC30 Variable Speed Drive
42 Pages
-
Parker Automation Controller
20 Pages
-
Parker Gearboxes
36 Pages
-
GVI Global Vehicle Inverter
16 Pages
-
RTS, RS, RX and AXEM Series
24 Pages
-
TMW Series Torque Motors
32 Pages
-
PSD1 Parker Servo Drive
16 Pages
-
ETH Electro Cylinder_2019
60 Pages
-
DC590+ Product Catalog
20 Pages
-
Torque Motors – Kit version
111 Pages
-
Frameless Servo Motors
44 Pages
-
HKW Series
133 Pages
-
GVM Global Vehicle Motor
24 Pages
-
PSD1 Parker Servo Drive
12 Pages
-
Belt Driven Positioners
151 Pages
-
PS / RS Series
16 Pages
-
PTN Planetary Gearbox
4 Pages
-
PE Series
12 Pages
-
Motion Solutions
16 Pages
-
ETHERNET Powerlink
20 Pages
-
SMB Motors
28 Pages
Archived catalogs
-
ETH Electro Cylinder_2012
56 Pages