PI/PD Series Medium Pressure Axial Piston Pumps Variable Displacement Catalog HY28-2665-01/P1/EN Effective:lNovember 2019l|lReplaces August 1,2014 ENGINEERING YOUR SUCCESS.
Open the catalog to page 1Axial Piston Pumps P1/PD Series WARNING - USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,...
Open the catalog to page 2Axial Piston Pumps P1/PD Series Variable displacement, axial piston pump for open-circuit applications Continuous operation at pressures up to 280 bar High drive speed models for mobile markets and low noise models for industrial markets Quiet and efficient control capability Cam bearing design Compact overall package size High power density Many different standard control options Modular controls for easy conversions High operating efficiency for lower power consumption and reduced heat generation Elastomer seals that eliminate gaskets and external leakage Simple hydraulic controls with “no-leak”...
Open the catalog to page 3Axial Piston Pumps P1/PD Series Single Configuration Shaft Seal Design Series Additional Control Options Displacement Stops Thru-Drive Mounting Pad & Coupling Special Features Pump Family Circuit Type Mounting & Ports Shaft Options 2 See controls options for design series selection Port Orientation 5 Not standard with thru drive. Contact factory for approval. Controls (B-Mod) Controls (A-Mod) 3 Requires application review. Consult factory. Work Port Type 6 On 60cc, only with SAE end ports Additional Control Options Thru-Drive Designation Description Special Features Pump Family Circuit Type Shaft...
Open the catalog to page 4Axial Piston Pumps P1/PD Series Mounting Designation Descriptions Parker Hannifin Corporation Hydraulic Pump and Power Systems Division Marysville, Ohio USA
Open the catalog to page 5Axial Piston Pumps P1/PD Series Shaft Torque Ratings NRD = No rear thru drive; RD = Rear thru drive Parker Hannifin Corporation Hydraulic Pump and Power Systems Division Marysville, Ohio USA
Open the catalog to page 6Axial Piston Pumps P1/PD Series Design Series Change Information The P1/PD has gone through a design series change for some control options. All the controls shown in this catalog except the Electronic Displacement and Pressure Control options (P, S, T, U, AG, AH) are now standard as Design Series B (B-mod). For the C, L, and AM controls, the controls were combined into a single universal control housing that can be used for any of the three options. Therefore, converting between those controls is very easy. For conversion details or other service information on the B-mod, please refer to the...
Open the catalog to page 7Axial Piston Pumps P1/PD Series Pressure Limiter Load Sensing and Pressure Limiter Adjustment Range = 26-280 bar (380-4060 psi) Pressure Limiter Adjustment Range = 26-280 bar (380-4060 psi) Differential Adjustment Range = 10-40 bar (150-580 psi) The "C0" pressure limiter control is used to limit the maximum system pressure. The control acts such that full pump displacement is achieved unless the system valve restricts the output flow or the load pressure reaches the maximum setting of the control. If pump flow is restricted by the system valve, the pump will provide only the flow demanded, but...
Open the catalog to page 8Axial Piston Pumps P1/PD Series The "AM" control allows the pump pressure compensator setting to be adjusted from a remote relief valve that is connected to the "X" port on the control. The control acts such that full pump displacement is achieved unless the system valve restricts the output flow or the load pressure reaches the maximum setting of the control. If pump flow is restricted by the system valve, the pump will provide only the flow demanded, but at the maximum pressure setting of the compensator control. If the outlet flow is completely blocked, the pump will destroke to zero displacement...
Open the catalog to page 9Control Options “AMT,” “ANT,” and “LOT” Torque Limiting Controls: (45-140cc only) AMT = Remote pressure limiting with torque limiting ANT = Pilot operated pressure limiting with torque limiting LOT = Load sense & pressure limiting with torque limiting These controls provide the benefit of pressure limiting control, plus the ability to limit the input torque when the power available from the prime mover is limited; or when the application power demand has both high flow/low pressure and low flow/high pressure operating conditions. “AMT” Control The "AMT" and "ANT" combine the pilot pressure limiter...
Open the catalog to page 10Axial Piston Pumps P1/PD Series Control Options “AE” and “AF” Electronic Proportional Pressure Limiting with Mechanical Pressure Limiter Minimum Pressure Default AE = 12 VDC Solenoid AF = 24 VDC Solenoid This control is the same as the AN control, but with the proportional relief valve included. It allows the pump pressure compensator setting to be adjusted by an on-board 4VP0150G24B1C1 (24V) or RE06M35W2N1KWXG087 (12V) proportional, electronic relief valve. The control acts such that full pump displacement is achieved unless the system pressure reaches the setting of the proportional relief...
Open the catalog to page 11Axial Piston Pumps P1/PD Series B-Mod Controls Information Electronic Unload/Cold Start C03 = Pressure limiting with 12VDC unload valve C06 = Pressure limiting with 24VDC unload valve L03 = Load sense & pressure limiting with 12VDC unload valve L06 = Load sense & pressure limiting with 24VDC unload valve “L03” & “L06” Controls - Load sensing & pressure limiting with unload function When the unload valve is in the spring position (de-energized), the pump is “loaded”. The load sense function requires the signal port be connected to load pressure, and the valve sends the load pressure to the spring...