1. Catalogs
  2. Parker Chomerics Division
  3. P1/PD Series Medium Pressure Axial Piston Pumps
video corpo

P1/PD Series Medium Pressure Axial Piston Pumps

P1/PD Series Medium Pressure Axial Piston Pumps
1 / 72 PagesView full catalog

P1/PD Series Medium Pressure Axial Piston Pumps

Product catalog summary
General Information & Technical Specs
The P1/PD Series are medium pressure axial piston pumps with variable displacement, designed for open-circuit applications. They operate continuously at pressures up to 280 bar and are available in high drive speed models for mobile markets and low noise models for industrial markets. Key features include quiet and efficient control capability, compact size, high power density, and modular controls for easy conversions. The pumps are equipped with elastomer seals to eliminate gaskets and external leakage, and they offer fast and stable compensator response. They are compatible with SAE and ISO standard mounting flanges and ports.
Ordering Information
The ordering code for the P1/PD Series includes options for shaft type, rotation, seal material, thru-drive mounting pad and coupling, displacement, port orientation, and control options. Various configurations are available to suit different applications, including mobile (P1), industrial (PD), and universal (45–140cc & B-mod only) configurations.
Shaft Technical Data
The document provides detailed specifications for shaft options, including torque ratings, radial and axial shaft load ratings, and shaft rotational stiffness. Maximum allowable shaft loads and moment ratings are also specified for different displacement models.
Performance Data
Performance data includes typical pump outlet flow, shaft input power, shaft bearing life, and noise characteristics. These metrics are crucial for assessing the suitability of the pump for specific applications.
Dimensional Data
Dimensional data is provided for various models (P1/PD 018, 028, 045, 060, 075 & 085, 100, 140), detailing the physical dimensions and mounting configurations.
Installation Information
Guidelines for proper installation are provided to ensure optimal performance and longevity of the pumps.
Offer of Sale
The document includes an offer of sale, outlining the terms and conditions under which the pumps are sold by Parker-Hannifin Corporation and its authorized distributors.
Warning - User Responsibility
A warning is issued regarding the user's responsibility for proper selection and use of the products to prevent potential hazards such as death, personal injury, and property damage. Users are advised to conduct their own analysis and testing to ensure all performance, endurance, maintenance, safety, and warning requirements are met.
Design Series Changes
The P1/PD series has undergone a design change for certain control options. Most controls are now standard as Design Series B (B-mod), with a universal control housing for C, L, and AM controls, facilitating easy conversion between these options.
Control Options
The document details various control options available for the pumps, including:
  • Pressure Limiter Control (C0): Limits maximum system pressure with an adjustment range of 26-280 bar.
  • Load Sensing and Pressure Limiter (L0, L2): Matches pump flow and pressure to system demands, reducing horsepower losses.
  • Remote Operated Pressure Limiter (AM): Allows remote adjustment of the pressure compensator setting.
  • Torque Limiting Controls (AMT, ANT, L0T): Combine pressure limiting with torque limiting functions to manage power demands efficiently.
  • Electronic Proportional Pressure Limiting (AE, AF): Uses a proportional relief valve for pressure adjustment, with options for 12VDC and 24VDC solenoids.
  • Electronic Unload/Cold Start (C03, C06, L03, L06): Features an unload function to reduce torque during cold starts.
Performance and Specifications
The document includes performance curves and response times for different control options, highlighting the pump's ability to adjust displacement and maintain pressure under various conditions.
Recommendations
For electronic controls, specific driver modules and amplifiers are recommended to ensure optimal performance.
Conclusion
The P1/PD Series pumps offer versatile control options to meet diverse hydraulic system requirements, with design improvements enhancing ease of use and adaptability.
Shaft Bearing Life
The document presents graphs showing the L-10 and B-10 life expectancy of shaft bearings at various RPMs and duty cycle pressures for different models (P1/PD 018, 028, 045, 060, 075, 085, 100, 140). The life expectancy varies significantly with changes in RPM and pressure, highlighting the importance of operating conditions on pump longevity.
Noise Characteristics
Anechoic sound pressure readings are provided for various models under zero and full flow conditions using ISO VG 32 fluid at 50°C inlet oil temperature. The sound levels are depicted across different RPMs and pressures, indicating the acoustic performance of the pumps.
Installation and Dimensional Data
Detailed dimensions for input shafts, mounting flanges, and port sizes are provided for models P1/PD-018 and P1/PD-028. The document specifies the standards conformed to, such as SAE and ISO, and provides measurements for various components, ensuring proper installation and compatibility.
Key Specifications
- Maximum speed rating for PD series is 1800 RPM.
- Various spline configurations and dimensions are detailed for different models.
- Port sizes and threading options are specified for both SAE and metric standards.
Recommendations
Proper adherence to specified installation dimensions and operating conditions is crucial for optimal performance and longevity of the pumps. Regular monitoring of noise levels and bearing life can help in predictive maintenance and avoiding unexpected downtimes.
Specifications
  • Port Conformance: SAE flanged ports conform to SAE J518, SAE o-ring ports to SAE J514, metric flanged ports to ISO 6162, metric o-ring boss ports to ISO 6149-1, and BSPP ports to ISO 228-1.
  • Port Sizes: Detailed port sizes are provided for each pump model, specifying inlet and outlet dimensions, thread types, and applicable standards.
Dimensional Data
  • Mounting Options: Information on SAE-A, SAE-B, and SAE-C mounting options is provided, including spline specifications such as number of teeth, pitch, pressure angle, and diameter measurements.
  • Input Shaft Dimensions: Dimensions for input shafts are detailed for each pump model, including major and minor diameters, pitch diameters, and key widths.
Key Data from Tables
  • Port Sizes: The document lists specific port sizes for each pump model, indicating the compatibility with various standards and thread types.
  • Spline Details: Spline specifications are provided for different mounting options, detailing the class, fit, and dimensional attributes.
Critical Information
  • Compliance: The document emphasizes compliance with international standards for hydraulic connections, ensuring compatibility and reliability in various applications.
  • Dimensional Precision: Detailed measurements ensure precise installation and integration into hydraulic systems.
Installation and Operation Guidelines
- Avoid side loading on the shaft; consult PARKER if unavoidable.
- Connect inlet and outlet lines to the pump's port block, ensuring maximum case pressure does not exceed 2 bar continuous or 4 bar intermittent.
- Ensure case pressure does not exceed inlet pressure by more than 0.5 bar.
- Drain plumbing should pass above the pump before reaching the reservoir, and the case leakage line must prevent back pressure over 2 bar.
- Use adequately sized and strong fluid lines to ensure free flow; flexible hoses are recommended.
- Clean and flush all system piping before pump installation.
- Do not use galvanized pipes due to flaking risks.
- System relief valves are recommended for safety.
Fluid and Maintenance Recommendations
- Use petroleum-based fluid with oxidation inhibition and anti-rust properties as per PARKER standard HF-1.
- Maintain fluid cleanliness at ISO 20/18/14 level to extend component life.
- Fluid temperature should not exceed 110°C at the case drain.
- Regularly change filters and ensure all fittings are tight.
Product Offering Overview
- Parker offers a wide range of hydraulic products including motors, pumps, power units, valves, and controls.
- The P1/PD series pumps are part of a broad line of energy-efficient hydraulic pumps.
Terms and Conditions
- Prices are valid for 30 days and may change due to various factors.
- Delivery dates are approximate; title and risk pass to the buyer upon carrier tender.
- Products are warranted to be free from defects for 18 months from delivery.
- Claims for shortages must be reported within 10 days of delivery.
- Seller's liability is limited to repair, replacement, or refund of the purchase price.
- Buyer is responsible for the final selection and application of the products.
- The agreement is governed by the laws of Ohio, with disputes settled in Cuyahoga County courts.
Indemnity for Infringement of Intellectual Property Rights
The seller is responsible for defending and indemnifying the buyer against allegations of infringement of U.S. intellectual property rights, provided the buyer notifies the seller within ten days of becoming aware of such allegations. The seller has the sole control over the defense and settlement negotiations. The seller may choose to procure the right for the buyer to continue using the product, replace or modify it, or accept its return with a refund minus depreciation. The seller is not liable for infringement claims based on buyer-provided information or modifications made by the buyer.
Taxes
Prices and charges exclude taxes such as excise, sales, use, property, or occupational taxes unless otherwise indicated.
Equal Opportunity Clause
For government contracts exceeding $10,000, equal employment opportunity clauses from Executive Order 11246 and related regulations are incorporated.
Product Updates and Warnings
The document includes updates on the P1/PD Series Axial Piston Pumps, such as added controls, model codes, and dimensional updates. A warning is provided about exposure to chemicals known to cause cancer and reproductive harm, in compliance with California's Proposition 65.
See more

Catalog excerpts

P1/PD Series Medium Pressure Axial Piston Pumps-1

PI/PD Series Medium Pressure Axial Piston Pumps Variable Displacement Catalog HY28-2665-01/P1/EN Effective:lNovember 2019l|lReplaces August 1,2014 ENGINEERING YOUR SUCCESS.

 Open the catalog to page 1
P1/PD Series Medium Pressure Axial Piston Pumps-2

Axial Piston Pumps P1/PD Series WARNING - USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,...

 Open the catalog to page 2
P1/PD Series Medium Pressure Axial Piston Pumps-3

Axial Piston Pumps P1/PD Series Variable displacement, axial piston pump for open-circuit applications Continuous operation at pressures up to 280 bar High drive speed models for mobile markets and low noise models for industrial markets Quiet and efficient control capability Cam bearing design Compact overall package size High power density Many different standard control options Modular controls for easy conversions High operating efficiency for lower power consumption and reduced heat generation Elastomer seals that eliminate gaskets and external leakage Simple hydraulic controls with “no-leak”...

 Open the catalog to page 3
P1/PD Series Medium Pressure Axial Piston Pumps-4

Axial Piston Pumps P1/PD Series Single Configuration Shaft Seal Design Series Additional Control Options Displacement Stops Thru-Drive Mounting Pad & Coupling Special Features Pump Family Circuit Type Mounting & Ports Shaft Options 2 See controls options for design series selection Port Orientation 5 Not standard with thru drive. Contact factory for approval. Controls (B-Mod) Controls (A-Mod) 3 Requires application review. Consult factory. Work Port Type 6 On 60cc, only with SAE end ports Additional Control Options Thru-Drive Designation Description Special Features Pump Family Circuit Type Shaft...

 Open the catalog to page 4
P1/PD Series Medium Pressure Axial Piston Pumps-5

Axial Piston Pumps P1/PD Series Mounting Designation Descriptions Parker Hannifin Corporation Hydraulic Pump and Power Systems Division Marysville, Ohio USA

 Open the catalog to page 5
P1/PD Series Medium Pressure Axial Piston Pumps-6

Axial Piston Pumps P1/PD Series Shaft Torque Ratings NRD = No rear thru drive; RD = Rear thru drive Parker Hannifin Corporation Hydraulic Pump and Power Systems Division Marysville, Ohio USA

 Open the catalog to page 6
P1/PD Series Medium Pressure Axial Piston Pumps-7

Axial Piston Pumps P1/PD Series Design Series Change Information The P1/PD has gone through a design series change for some control options. All the controls shown in this catalog except the Electronic Displacement and Pressure Control options (P, S, T, U, AG, AH) are now standard as Design Series B (B-mod). For the C, L, and AM controls, the controls were combined into a single universal control housing that can be used for any of the three options. Therefore, converting between those controls is very easy. For conversion details or other service information on the B-mod, please refer to the...

 Open the catalog to page 7
P1/PD Series Medium Pressure Axial Piston Pumps-8

Axial Piston Pumps P1/PD Series Pressure Limiter Load Sensing and Pressure Limiter Adjustment Range = 26-280 bar (380-4060 psi) Pressure Limiter Adjustment Range = 26-280 bar (380-4060 psi) Differential Adjustment Range = 10-40 bar (150-580 psi) The "C0" pressure limiter control is used to limit the maximum system pressure. The control acts such that full pump displacement is achieved unless the system valve restricts the output flow or the load pressure reaches the maximum setting of the control. If pump flow is restricted by the system valve, the pump will provide only the flow demanded, but...

 Open the catalog to page 8
P1/PD Series Medium Pressure Axial Piston Pumps-9

Axial Piston Pumps P1/PD Series The "AM" control allows the pump pressure compensator setting to be adjusted from a remote relief valve that is connected to the "X" port on the control. The control acts such that full pump displacement is achieved unless the system valve restricts the output flow or the load pressure reaches the maximum setting of the control. If pump flow is restricted by the system valve, the pump will provide only the flow demanded, but at the maximum pressure setting of the compensator control. If the outlet flow is completely blocked, the pump will destroke to zero displacement...

 Open the catalog to page 9
P1/PD Series Medium Pressure Axial Piston Pumps-10

Control Options “AMT,” “ANT,” and “LOT” Torque Limiting Controls: (45-140cc only) AMT = Remote pressure limiting with torque limiting ANT = Pilot operated pressure limiting with torque limiting LOT = Load sense & pressure limiting with torque limiting These controls provide the benefit of pressure limiting control, plus the ability to limit the input torque when the power available from the prime mover is limited; or when the application power demand has both high flow/low pressure and low flow/high pressure operating conditions. “AMT” Control The "AMT" and "ANT" combine the pilot pressure limiter...

 Open the catalog to page 10
P1/PD Series Medium Pressure Axial Piston Pumps-11

Axial Piston Pumps P1/PD Series Control Options “AE” and “AF” Electronic Proportional Pressure Limiting with Mechanical Pressure Limiter Minimum Pressure Default AE = 12 VDC Solenoid AF = 24 VDC Solenoid This control is the same as the AN control, but with the proportional relief valve included. It allows the pump pressure compensator setting to be adjusted by an on-board 4VP0150G24B1C1 (24V) or RE06M35W2N1KWXG087 (12V) proportional, electronic relief valve. The control acts such that full pump displacement is achieved unless the system pressure reaches the setting of the proportional relief...

 Open the catalog to page 11
P1/PD Series Medium Pressure Axial Piston Pumps-12

Axial Piston Pumps P1/PD Series B-Mod Controls Information Electronic Unload/Cold Start C03 = Pressure limiting with 12VDC unload valve C06 = Pressure limiting with 24VDC unload valve L03 = Load sense & pressure limiting with 12VDC unload valve L06 = Load sense & pressure limiting with 24VDC unload valve “L03” & “L06” Controls - Load sensing & pressure limiting with unload function When the unload valve is in the spring position (de-energized), the pump is “loaded”. The load sense function requires the signal port be connected to load pressure, and the valve sends the load pressure to the spring...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.