Contact Information
Parker-Hannifin Corporation, domnick hunter, Process Filtration - North America, 2340 Eastman Avenue, Oxnard, California, USA 93030. Toll-free: +1 877 784 2234, Phone: +1 805 604 3400, Fax: +1 805 604 3401, Email: [email protected], Website: www.parker.com/processfiltration.
Product Overview
The Fulflo® Mega-Flow™ Plus Filter Cartridges are designed for high flow applications requiring absolute particle removal. Each cartridge can handle up to 175 gpm (662 lpm), reducing the number of cartridges and housing size needed. The cartridges feature a 6-inch diameter and are equivalent to eight standard cartridges. They include a positive O-ring seal and built-in handle for easy installation. Available with pleated polypropylene media, they offer absolute ratings from 1 μm to 150 μm.
Applications
  • Potable Water
  • Vegetable Oil
  • Wastewater
  • Lubricants
  • Food and Beverage
  • Coolants
Benefits
  • High flow capacity reduces cartridge count and change time
  • Smaller housing requirements
  • Easy and safe cartridge change with built-in handle
  • O-ring seal ensures filtration integrity
  • Polypropylene media enhances fluid compatibility
  • Low pressure drop and long service life due to high surface area pleated design
  • Compliance with FDA regulations per CFR Title 21
  • Available in horizontal and vertical housings for flow rates up to 3325 gpm (12,586 lpm)
  • Minimizes process interruptions
Specifications
  • Absolute Filtration Ratings: Polypropylene (1-70 μm), Cellulose (10-150 μm)
  • Materials: Polypropylene microfiber, Cellulose with phenolic binder, Glass Filled Polypropylene end caps
  • O-Rings: Buna-N, EPR, Silicone, Fluoroelastomer
  • Operating Conditions: Change Out Differential Pressure - 35 psid (2.4 bar), Max Flow Rate - 175 gpm (662 lpm), Max Temperature - 200°F (93°C), Max Differential Pressure - 150 psid (10 bar)
  • Dimensions: 6 in. OD, 3.5 in. ID, 40 in. long
  • Surface Area: 55 - 60 ft² (5.1 - 5.6 m²)
Ordering Information
Cartridge codes and specifications are provided for different micron ratings and media types, including flow factors and efficiency ratings.
See more

Catalog excerpts

Fulflo Mega-Flow Plus Filter Cartridges-1

Fulflo® Mega-Flow ™ Plus Filter Cartridges Absolute-rated, high-flow capacity pleated cartridge Parker's Fulflo® Mega-Flow™ Plus cartridges are Ideally suited for high flow applications where aPsolute particle removal Is required. Each Mega-Flow Plus cartridge can handle significantly reducing the numPer of cartridges required as well as the housing size. Each 6 inch (152 mm) diameter Mega-Flow+ cartridge has flow capacity equal to 8 standard 2 1/2 Inch OD X 40 Inch long cartridges. Positive O-rlng seals and a built In handle make cartridge Installation reliable, fast and easy. Mega-Flow Plus cartridges are available with pleated polypropylene media for use in a wide variety of fluids. Absolute ratings range Contact Information Benefits Parker-Hannifin Corporation domnick hunter Process Filtration - North America High flow capacity means fewer cartridges and less time to change High flow capacity allows smaller Built in handle makes change fast, O-ring seal assures filtration Choice of polypropylene media expands fluid compatibility High surface area pleated design provides low pressure drop and long service life Polypropylene cartridges comply with FDA regs. per CFR Title 21 Horizontal and vertical housings available for flow rates up to Reduces process interruptions • Potable Water ENGINEERING YOUR SUCCESS.

 Open the catalog to page 1
Fulflo Mega-Flow Plus Filter Cartridges-2

Fulflo® Mega-Flow™ Plus Filter Cartridges Absolute Filtration Ratings • Polypropylene microfiber (P Code) • Cellulose with phenolic binder (C Code) Support Layers • Glass Filled Polypropylene • Buna-N, EPR, Silicone, Fluoroelastomer Recommended Operating Conditions: Change Out Differential Pressure Maximum Flow Rate Maximum Temperature Maximum Differential Pressure Surface Area Ordering Information Flow Rate and Pressure Drop Formulas Flow Rate (gpm) = Clean AP x Viscosity X Flow Factor Clean AP = Flow Rate x Viscosity x Flow Factor 1. Clean AP is psi differential at start. 2. Viscosity Is centistokes....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.