54 COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES S1DX S1DX 3 operation modes added for fuller lineup Now, operation modes include not only On Delay, but Flicker, One Shot, and One Cycle modes as well. Operation can be checked easily Power supply: Red Operation: Green LED display Easier than ever to read and use Large-sized transparent dial makes setting time easy! High precision Repeatability error: 1% Output contact relay construction Available contact relay output types: 2C and 4C Output terminal A plug-in terminal and printed circuit terminal are provided. Panels can be installed In addition to conventional DIN rail installation, panels can be installed using an installation frame. The compact timer size means that larger panels can be used. CE markings accommodated EMC directive (EN50081 - 2/EN50082 - 2) Low-voltage directive (VDE0435/Part 2021) Features 24V AC Part number S1DX-A2C0.5S-AC24V S1DX-A2C1S-AC24V S1DX-A2C3S-AC24V S1DX-A2C5S-AC24V S1DX-A2C10S-AC24V S1DX-A2C30S-AC24V S1DX-A2C60S-AC24V S1DX-A2C3M-AC24V S1DX-A2C10M-AC24V S1DX-A2C30M-AC24V S1DX-A2C60M-AC24V S1DX-A2C3H-AC24V S1DX-A4C0.5S-AC24V S1DX-A4C1S-AC24V S1DX-A4C3S-AC24V S1DX-A4C5S-AC24V S1DX-A4C10S-AC24V S1DX-A4C30S-AC24V S1DX-A4C60S-AC24V S1DX-A4C3M-AC24V S1DX-A4C10M-AC24V S1DX-A4C30M-AC24V S1DX-A4C60M-AC24V S1DX-A4C3H-AC24V 100 to 120V AC Part number S1DX-A2C0.5S-AC120V S1DX-A2C1S-AC120V S1DX-A2C3S-AC120V S1DX-A2C5S-AC120V S1DX-A2C10S-AC120V S1DX-A2C30S-AC120V S1DX-A2C60S-AC120V S1DX-A2C3M-AC120V S1DX-A2C10M-AC120V S1DX-A2C30M-AC120V S1DX-A2C60M-AC120V S1DX-A2C3H-AC120V S1DX-A4C0.5S-AC120V S1DX-A4C1S-AC120V S1DX-A4C3S-AC120V S1DX-A4C5S-AC120V S1DX-A4C10S-AC120V S1DX-A4C30S-AC120V S1DX-A4C60S-AC120V S1DX-A4C3M-AC120V S1DX-A4C10M-AC120V S1DX-A4C30M-AC120V S1DX-A4C60M-AC120V S1DX-A4C3H-AC120V 200 to 220V AC Part number S1DX-A2C0.5S-AC220V S1DX-A2C1S-AC220V S1DX-A2C3S-AC220V S1DX-A2C5S-AC220V S1DX-A2C10S-AC220V S1DX-A2C30S-AC220V S1DX-A2C60S-AC220V S1DX-A2C3M-AC220V S1DX-A2C10M-AC220V S1DX-A2C30M-AC220V S1DX-A2C60M-AC220V S1DX-A2C3H-AC220V S1DX-A4C0.5S-AC220V S1DX-A4C1S-AC220V S1DX-A4C3S-AC220V S1DX-A4C5S-AC220V S1DX-A4C10S-AC220V S1DX-A4C30S-AC220V S1DX-A4C60S-AC220V S1DX-A4C3M-AC220V S1DX-A4C10M-AC220V S1DX-A4C30M-AC220V S1DX-A4C60M-AC220V S1DX-A4C3H-AC220V 220 to 240V AC Part number S1DX-A2C0.5S-AC240V S1DX-A2C1S-AC240V S1DX-A2C3S-AC240V S1DX-A2C5S-AC240V S1DX-A2C10S-AC240V S1DX-A2C30S-AC240V S1DX-A2C60S-AC240V S1DX-A2C3M-AC240V S1DX-A2C10M-AC240V S1DX-A2C30M-AC240V S1DX-A2C60M-AC240V S1DX-A2C3H-AC240V S1DX-A4C0.5S-AC240V S1DX-A4C1S-AC240V S1DX-A4C3S-AC240V S1DX-A4C5S-AC240V S1DX-A4C10S-AC240V S1DX-A4C30S-AC240V S1DX-A4C60S-AC240V S1DX-A4C3M-AC240V S1DX-A4C10M-AC240V S1DX-A4C30M-AC240V S1DX-A4C60M-AC240V S1DX-A4C3H-AC240V Time range 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.1 to 3 min 0.5 to 10 min 1 to 30 min 3 to 60 min 0.1 to 3 h 0.05 to 0.5 s 0.1 to 1 s 0.1 to 3 s 0.2 to 5 s 0.5 to 10 s 1 to 30 s 3 to 60 s 0.1 to 3 min 0.5 to 10 min 1 to 30 min 3 to 60 min 0.1 to 3 h Time-out 2 Form C type Time-out 4 Form C type Product types • Plug-in terminal Power ON-delay AC operating type * Wire springs (ADX18005) are included. UL File No.: E122222 CSA File No.: LR39291 02/2003

Open the catalog to page 1
S1DX – analog timer - 3

56 S1DX Specifications Time accuracy (max.) Min. power off time Operating time fluctuation & Power off time change error Temperature error Voltage error Setting error [Except 0.5s & 1s types] ±1% [0.5s type]: ±(2%+10ms) [1s type]: ±(1%+10ms) [Except 0.5s & 1s types] ±1% [0.5s type]: ±(2%+10ms) [1s type]: ±(1%+10ms) (power off time change at the range of 0.1 s to 1 h) ±5% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F) (at the operating voltage changes between –20 to +10%) ±10% (Full-scale value) 100ms 24V, 100 to 120V, 200 to 220V, 220 to 240V 80 to 110% of rated...

Open the catalog to page 3
S1DX – analog timer - 4

57 Data 10 100 1,000 0.01 0.1 1 5 7 10 2 Form C type 4 Form C type Load voltage, V Load current, A Load current, A 2 4 6 8 0 100 200 300 400 500 1,000 No. of operations, ×104 No load life No load life: Min. 107 ope. Rated load life: Min. 2×105 ope. 2 Form C type 4 Form C type –0.1 –0.2 0.2 0.1 Voltage error, % 80 Applied voltage, 100 110 %V –0.1 –0.2 0.2 0.1 Voltage error, % 80 Applied voltage, 100 110 %V –0.5 –1 20 50 0.5 1 –10 Temperature error, % Ambient temperature, °C –0.5 –1 20 50 0.5 1 –10 Temperature error, % Ambient temperature, °C –0.5 –1 20 50 0.5 1 –10 Temperature error, %...

Open the catalog to page 4
S1DX – analog timer - 5

58 S1DX Operation mode and color Scale intervals Operation type Description Time chart Power ON-delay Power Flicker Power One-shot Power One-cycle Operation mode indicator color OFF OFF OFF ON ON ON (NC) (NO) Timed-out contact Timed-out contact Power supply (NC) (NO) Timed-out contact Timed-out contact Power supply (NC) (NO) Timed-out contact Timed-out contact Power supply (NC) (NO) Timed-out contact Timed-out contact Power supply T T T t < T OFF T T T T t OFF ON OFF ON OFF OFF ON OFF ON OFF ON ON ON OFF T OFF OFF ON ON ON OFF T OFF One pulse time: Approx. 1 s OFF ON ON ON Yellow Blue Green...

Open the catalog to page 5
S1DX – analog timer - 6

59 Precautions during usage The typical surge absorption elements include a varistor, a capacitor, and a diode. If a surge absorption element is used, use an oscilloscope to see whether or not the foreign surge exceeding the specified value appears. Operation voltage 100 to 120V AC 200 to 220V AC 220 to 240V AC Surge voltage 4,000V 24V AC 12V DC 24V DC 1,000V 0 0 1.2 50 30 50 Time Crest value 100 90 (ìs) Crest value (%) • Single-pole, full-wave voltage for surge waveform [±(1.2 × 50) ìs] S1DX • HC2 slim DIN terminal socket • HC2 DIN high terminal socket • HC4 DIN high terminal socket • HC4...

Open the catalog to page 6

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages