Catalog excerpts
Digital Pressure Sensor DP-101(A) / 102(A) SERIES Ver. 2 Conforming to EMC Directive Pressure Sensor Evolutions To Come
Open the catalog to page 1Achieved further efficiency with 4 upgrades, keeping the same operability Note: The upgrade will be implemented from production in October 2013, based on stock status. Upgrade 1 Superior visibility Improved visibility in Digital Display Improvements to the digital display deliver a wide viewing angle along with increased clarity. The display pressure range and set pressure range have also been increased. Old DP-100 series Upgrade 2 Long-distance transmission of analog output Addition of analog current output capability to multifunctional models Users can now select either voltage output or...
Open the catalog to page 2Dual Display Direct setting “Current value” and “threshold value” can be checked at the same time! Current value Threshold value ect setting Dir Works like a dial control type sensor Main display Comparative Output 1 operation indicator Comparative Output 2 operation indicator Work as analog voltage output operation indicator in Multi-function type Mode selection key Dual display allows direct setting of threshold value Previous model with single display Threshold value setting method Equipped with a 30 mm 1.181 in square compact-sized dual display. The current value and the threshold value...
Open the catalog to page 3Copy function helps operation to be accurate and quick Copy function reduces man-hours and human error Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when machinery design are changed, there would be less change in work orders. Setting details can be copied. Master sensor Slave sensor Power supply +V Details transmitted Details received Note: Settings cannot be copied...
Open the catalog to page 4Setting is smooth and easy The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use. The setting levels are clearly separated into “RUN mode” for operation settings that are carried out daily, “MENU SETTING mode” for basic settings, and “PRO mode” for special and detailed setting. These make setting operations easy to understand and easy to carry out. RUN mode Settings such as threshold value adjustment and key lock operation can be carried out while the sensor is operating. Simple setting MENU SETTING mode MENU SETTING mode Basic settings such as output...
Open the catalog to page 5Full range of performance and functions in a compact body All lineup models are compound pressure types High performance accomplished No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 % F.S. repeatability, achieving high detection performance. Ideal for applications such as suction. No misoperations...
Open the catalog to page 6Equipped with auto-reference / remote zero-adjustment functions, More precise pressure management is achieved with a minimum of effort If the reference pressure of the device changes, two functions are selectable. One is auto-reference function, which partially shift the comparative output judgment level by the amount that the reference pressure shifts. The other is remote zero-adjustment function, which can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are required....
Open the catalog to page 7Other useful functions Sub display can be customized Setting details can be recognized at a glance The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. The DP-100 setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful such as when receiving technical support by telephone. What are the check codes for the setting? The code on the main display is 3205....
Open the catalog to page 8Installation is also easy! Tight installation to panels is possible An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. Tight installation is possible Neat and space saving Front protection cover available MS-DP1-3 A single mounting hole! An exclusive mounting bracket that supports tight installation is available Space savings can also be achieved even when an L-shaped mounting bracket is used. MS-DP1-1 Tight installation is possible Ceiling mounting Floor mounting Positioning bosses for easier mounting bracket installation Rear...
Open the catalog to page 9DP-100 Flat installation on the wall by shifting the direction For short pressure port type of the pressure port Rc1/8 conversion bushing is available. Compatible For short pressure port type with previous model By mounting the flat attachment to DP-10 -M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible. By equipping the push-in converter with DP-10 -M(-P), pressure port can be converted from M5 female thread to Rc1/8 female thread. Bore diameter conversion to the DP2 / DP3 series is...
Open the catalog to page 10DP-100 OPTIONS Connector attached cable Designation M8 connector attached cable Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. Allows installation to panels with thic ness of 1 to 6 mm 0.039 to 0.236 in. Multiple sensors can also be mounted closely. Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed set-up, please use panel mounting brac et MS-DP1-2 for panel mounting. Front protection cover Protects the adjustment...
Open the catalog to page 11All Panasonic Electric Works Europe catalogs and technical brochures
-
FM-200
12 Pages
-
Automation Controls Catalog
14 Pages
-
FPWIN Pro
8 Pages
-
Automation Controls Catalog
14 Pages
-
GX-F/H SERIES
16 Pages
-
FOR SENSORS PRODUCT FINDER
2 Pages
-
Short form SENSORS
124 Pages
-
Programmable Logic Controllers
32 Pages
-
IONIZER
36 Pages
-
PhotoMOS Catalog
354 Pages
-
Catalog Automotive Relays
210 Pages
-
AC Servo
155 Pages
-
Sensor short form
132 Pages
-
MINAS A5 SERVO DRIVES
28 Pages
-
HIGHLIGHTS FOR ECO INNOVATIONS
12 Pages
-
Catalogue-connectors
158 Pages
-
Fire alarm systems 2013
28 Pages
-
Shortform Temperature Controller
28 Pages
-
ELECTROMECHANICAL RELAYS
626 Pages
-
EY 7443 Auto Drill & Driver
2 Pages
-
Sealing Guns 2012/2013
8 Pages
-
New Products Autumn 2012
20 Pages
-
Catalog MINAS A5 series
85 Pages
-
FP-Safe catalog
12 Pages
-
Overview HMI
36 Pages
-
Overview Eco-POWER METERs
20 Pages
-
Panasonic Automation Products
28 Pages
-
Catalog built-in sensors
66 Pages
-
Catalog Microwave Devices
69 Pages
-
LC4H - digital counter
9 Pages
-
Limit switches AZH
14 Pages
-
Fire alarm system 2011/2012
28 Pages
-
Imagechecker P400XD
20 Pages
-
2D Code Reading Sensor PD60 / 65
12 Pages
-
FP-e: PLC for panel mounting
8 Pages
-
UJ30/35
12 Pages
-
GN-series touch terminals
36 Pages
-
Eco-power meters
16 Pages
-
Laser markers
28 Pages
-
Catalog timers & counters
160 Pages
-
Catalog limit switches
52 Pages
-
PHOTOMOS & SOLID STATE RELAYS
356 Pages
-
Catalog Switches
186 Pages
Archived catalogs
-
P400MA and P400 Imagecheckers
20 Pages
-
Turquoise switch series
28 Pages
-
Catalogue operation switches
156 Pages
-
R-1755 R-1650
2 Pages
-
Laserdrillable Prepreg
1 Pages
-
R-1566W R-1551W
1 Pages
-
MC-100EX/MS
1 Pages
-
Base 2324
2 Pages
-
Heat detectors 4375 and 4376
2 Pages
-
Multi detector 4350
2 Pages
-
Addressable siren 3377
2 Pages
-
External power supply 3366
2 Pages
-
Analog base 3312F / FL
2 Pages
-
Analog base 3312
2 Pages
-
Analog multi detector 4300
2 Pages
-
Analog heat detector 3308
2 Pages
-
Fire alarm system EBL128
2 Pages
-
Fire alarm system EBL512
2 Pages
-
Dicool
24 Pages
-
Eco-POWER METER KW4S
6 Pages
-
KW4M Eco-POWER METER
4 Pages
-
KW8M Eco-POWER METER
8 Pages
-
S1DX – analog timer
6 Pages
-
PM4H-W - analog timer - twin
5 Pages
-
PM4H - analog timer
6 Pages
-
PM5S - analog DIN-rail timer
7 Pages
-
QM4H - digital timer
4 Pages
-
LT4H-W
8 Pages
-
LT4H - digital timer
6 Pages
-
KR20 Wireless Unit
8 Pages
-
PV500 Imagechecker
20 Pages
-
Micro-Imagechecker AX30/AX40
16 Pages
-
PV310 Micro-Imagechecker
12 Pages
-
LightPix AE20
4 Pages
-
PD60/65 2D Code Readers
6 Pages
-
Panasonic Automation Products
12 Pages
-
Push Button Switches - ND Series
41 Pages
-
Push Button Switches - NS Series
11 Pages
-
AJ9 (J9) SWITCHES
6 Pages
-
AJ7 (J7) SWITCHES
8 Pages
-
AJ4 (J4) TOGGLE SWITCHES
6 Pages
-
TURQUOISE SNAP SWITCHES (AJN1/2)
10 Pages
-
Catalogue snap action relays
124 Pages
-
Electromechanical Relays
571 Pages
-
P400 and P400S
20 Pages
-
Micro-Imagechecker AX40
16 Pages
-
Brochure "2D Code Reader PD50"
12 Pages
-
A-Series
6 Pages
-
Brochure "LightPix AE20"
4 Pages
-
Imagechecker Brochure
32 Pages
-
Easy User Guide 'Matching'
5 Pages