31 Features • 24-240V AC/DC free-voltage input • Built-in Screw terminals • 6 different operation modes: (PM5S-A) • Multiple time ranges — 1 s to 500 h (Max.) • Slim body — DIN 22.5 mm .886 inch • 0 setting instantaneous output operation • UL/C-UL/CE approval 75.0 2.953 22.5 .886 98.5 3.878 mm inch Product types Type PM5S-M PM5S-A PM5S-S Operation mode Contact arrangement Time range Rated operating voltage Protective construction Part number PM5S-A-24-240V PM5S-S-24-240V PM5S-M-24-240V 16 selectable ranges 1s to 500h Relay Timed-out 1 Form C Instantaneous 1 Form C Relay Timed-out 2 Form C Relay Timed-out 2 Form C 6 operation modes • Pulse ON-delay • Pulse Flicker • Pulse ON-flicker • Signal OFF-delay • Pulse One-shot • Pulse One-cycle Power ON-delay 6 operation modes (With instantaneous contact) • Pulse ON-delay • Pulse Flicker • Pulse ON-flicker • Signal OFF-delay • Pulse One-shot • Pulse One-cycle IP40 24 to 240V AC/DC PM5S-A/PM5S-S/PM5S-M All types of PM5S timer have multi-time range. 16 time ranges are selectable. 1s to 500h (Max. range) is controlled. Time range 1 Scale Time unit 0.1s to 1s sec min hrs 10h 0.1 min to 1 min 0.1h to 1h 1.0h to 10h 5 Control 0.5s to 5s time range 0.5 min to 5 min 0.5h to 5h 5h to 50h 10 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h 50 5s to 50s 5 min to 50 min 5h to 50h 50h to 500h Note: 0 setting is for instantaneous output operation. C-UL File No.: E59504 (Vol. 3) DIN24 SIZE MULTI-RANGE ANALOG TIMER PM5S-A PM5S-S PM5S-M PM5S-A/S/M 02/2003
Open the catalog to page 132 CHARACTERISTICS WIRING DIAGRAMS Item Type PM5S-A PM5S-S Rated operating voltage 24 to 240V AC/DC 50/60Hz common 5A 250V AC (resistive load) Power ON-delay Pulse ON-delay Pulse Flicker Pulse ON-Flicker Signal OFF-delay Pulse One-shot Pulse One-cycle Pulse ON-delay Pulse Flicker Pulse ON-flicker Signal OFF-delay Pulse One-shot Pulse One-cycle (with instantaneous contact) Rated frequency Output rating 1s to 500h (Max.) 16 time ranges switchable ±0.3% (power off time change at the range of 0.1s to 1h) ±10% (Full-scale value) ±0.5% (at the operating voltage changes between 85 to 110%) Max....
Open the catalog to page 234 OPERATION MODE PM5S-A/M Note: Keep 0.1s or more for power off time. Keep 0.05s or more for signal, input time. Operation mode Operation Time chart Power supply Signal A1-B1 Relay output (NO contact) OUT. LED POWER LED ON ON ON T T Power supply Signal A1-B1 Relay output (NO contact) OUT. LED POWER LED ON ON ON T T t1 T t2 Power supply Signal A1-B1 Relay output (NO contact) OUT. LED POWER LED ON ON ON T T t1 T T Power supply Signal A1-B1 Relay output (NO contact) OUT. LED POWER LED ON ON ON T t1 t2 LED lighting LED flickering T: Setting time t1, t2.ÿ . ÿ Turn the operation selector to ....
Open the catalog to page 435 Note: Keep 0.1s or more for power off time. Keep 0.05s or more for signal, input time. Operation mode Operation Time chart Turn the operation selector to . Timing operation starts when terminals A1 – B1 are connected while power is ON. Control output is turned on after the set time, the pulse is 0.5 to 1.0 s. OC PM5S-S Operation mode Operation Time chart When power is applied continuously, the time cycle begins. The output contacts change state after the time delay is completed. Power ON-delay ON ON T T t1 0.5-1.0S Power supply Signal A1-B1 Relay output (NO contact) OUT. LED POWER LED ON...
Open the catalog to page 536 INPUT CONNECTIONS The inputs of the PM5S-A/M are voltage (voltage imposition or open) inputs. MOUNTING AND DISMOUNTING The PM5S should be mounted as horizontally as possible. When mounting the PM5S on a socket mounting track, hook portion (A) of the Timer to an edge of the track first, and then depress the Timer in the direction of (B). When dismounting the PM5S pull out portion (C) with a flatblade screwdriver and remove the Timer from the mounting track. POWER SUPPLIES The PM5S Series is provided with a transformerless power supply system. An electric shock may be received if the input...
Open the catalog to page 637 Operating voltage 24 to 240 V AC Surge voltage 4,000 V TERMINAL CONNECTIONS • Refer to the terminal layout and wiring diagram and securely connect the terminals accordingly. • Do not allow control output to exceed rated control capacity. 1. When one input signal is simultaneously applied to more than one timer, be sure to avoid the wiring shown in Fig. A. Otherwise, the short-circuit current will flow and cause damage. Be sure to align the polarity of the power supply as shown in Fig. B. 2. External surge protection may be required if the following values are exceeded. Otherwise, the...
Open the catalog to page 7All Panasonic Electric Works Europe catalogs and technical brochures
-
FM-200
12 Pages
-
Automation Controls Catalog
14 Pages
-
FPWIN Pro
8 Pages
-
Automation Controls Catalog
14 Pages
-
GX-F/H SERIES
16 Pages
-
FOR SENSORS PRODUCT FINDER
2 Pages
-
Short form SENSORS
124 Pages
-
Programmable Logic Controllers
32 Pages
-
IONIZER
36 Pages
-
PhotoMOS Catalog
354 Pages
-
Catalog Automotive Relays
210 Pages
-
AC Servo
155 Pages
-
Sensor short form
132 Pages
-
MINAS A5 SERVO DRIVES
28 Pages
-
HIGHLIGHTS FOR ECO INNOVATIONS
12 Pages
-
Catalogue-connectors
158 Pages
-
Fire alarm systems 2013
28 Pages
-
Shortform Temperature Controller
28 Pages
-
ELECTROMECHANICAL RELAYS
626 Pages
-
EY 7443 Auto Drill & Driver
2 Pages
-
Sealing Guns 2012/2013
8 Pages
-
New Products Autumn 2012
20 Pages
-
Catalog MINAS A5 series
85 Pages
-
FP-Safe catalog
12 Pages
-
Overview HMI
36 Pages
-
Overview Eco-POWER METERs
20 Pages
-
Panasonic Automation Products
28 Pages
-
Catalog built-in sensors
66 Pages
-
Catalog Microwave Devices
69 Pages
-
LC4H - digital counter
9 Pages
-
Limit switches AZH
14 Pages
-
Fire alarm system 2011/2012
28 Pages
-
Imagechecker P400XD
20 Pages
-
2D Code Reading Sensor PD60 / 65
12 Pages
-
FP-e: PLC for panel mounting
8 Pages
-
UJ30/35
12 Pages
-
GN-series touch terminals
36 Pages
-
Eco-power meters
16 Pages
-
Laser markers
28 Pages
-
Catalog timers & counters
160 Pages
-
Catalog limit switches
52 Pages
-
PHOTOMOS & SOLID STATE RELAYS
356 Pages
-
Catalog Switches
186 Pages
Archived catalogs
-
P400MA and P400 Imagecheckers
20 Pages
-
Turquoise switch series
28 Pages
-
Catalogue operation switches
156 Pages
-
R-1755 R-1650
2 Pages
-
Laserdrillable Prepreg
1 Pages
-
R-1566W R-1551W
1 Pages
-
MC-100EX/MS
1 Pages
-
Base 2324
2 Pages
-
Heat detectors 4375 and 4376
2 Pages
-
Multi detector 4350
2 Pages
-
Addressable siren 3377
2 Pages
-
External power supply 3366
2 Pages
-
Analog base 3312F / FL
2 Pages
-
Analog base 3312
2 Pages
-
Analog multi detector 4300
2 Pages
-
Analog heat detector 3308
2 Pages
-
Fire alarm system EBL128
2 Pages
-
Fire alarm system EBL512
2 Pages
-
Dicool
24 Pages
-
Eco-POWER METER KW4S
6 Pages
-
KW4M Eco-POWER METER
4 Pages
-
KW8M Eco-POWER METER
8 Pages
-
S1DX – analog timer
6 Pages
-
PM4H-W - analog timer - twin
5 Pages
-
PM4H - analog timer
6 Pages
-
QM4H - digital timer
4 Pages
-
LT4H-W
8 Pages
-
LT4H - digital timer
6 Pages
-
KR20 Wireless Unit
8 Pages
-
PV500 Imagechecker
20 Pages
-
Micro-Imagechecker AX30/AX40
16 Pages
-
PV310 Micro-Imagechecker
12 Pages
-
LightPix AE20
4 Pages
-
PD60/65 2D Code Readers
6 Pages
-
Panasonic Automation Products
12 Pages
-
Push Button Switches - ND Series
41 Pages
-
Push Button Switches - NS Series
11 Pages
-
AJ9 (J9) SWITCHES
6 Pages
-
AJ7 (J7) SWITCHES
8 Pages
-
AJ4 (J4) TOGGLE SWITCHES
6 Pages
-
TURQUOISE SNAP SWITCHES (AJN1/2)
10 Pages
-
Catalogue snap action relays
124 Pages
-
Electromechanical Relays
571 Pages
-
P400 and P400S
20 Pages
-
Micro-Imagechecker AX40
16 Pages
-
Brochure "2D Code Reader PD50"
12 Pages
-
A-Series
6 Pages
-
Brochure "LightPix AE20"
4 Pages
-
Imagechecker Brochure
32 Pages
-
Easy User Guide 'Matching'
5 Pages