PM4H-W - analog timer - twin - 1

50 PM4H-W DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS PM4H-W Features • A single twin timer unit that repeats (variable) ON/OFF. • Multiple ranges with a 0.1 s to 500 h time specification on a single unit. • The output ON/OFF operation is indicated by red and green LED’s. It’s easy to check the operation at a glance. • The AC free power supply and shorter body make it easier to use. • A new screw terminal type has been added to the conventional pin type. Wiring can be done easily with a screwdriver. • Compliant with UL, CSA, CE and LLOYD. 48 1.890 48 1.890 62.5 2.461 mm inch Specifications Item Type PM4H-W Rated operating voltage 100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DC 50/60Hz common (AC operating type) 5A 250V AC (resistive load) Cyclic (OFF-start/Twin operation) Rated frequency Rated control capacity 1s to 500h 16 time ranges switchable (T1, T2 time setting individually) ..0.3% (power off time change at the range of 0.3s to 1h) ..5% (Full-scale value) ..0.5% (at the operating voltage changes between 85 to 110%) Max. 100m.. (at 1A 6V DC) Timed-out 2 Form C ..2% (at 20..C ambient temp. at the range of –10 to +50..C +14 to 122..F) Time range Operation time fluctuation 2..107 105 (at rated control capacity) Mechanical (contact) Electrical (contact) Allowable operating voltage range 85 to 110% of rated operating voltage (at 20..C coil temp.) Ambient temperature –10 to +50..C +14 to +122..F Ambient humidity 30 to 85%RH (non-condensing) Atmospheric pressure 860 to 1,060hPa Ripple factor (DC type) 20% Protective construction IP65 on front panel (using rubber gasket ATC18002) Weight 120g 4.233 oz (Pin type), 130g 4.586 oz (Screw terminal type) 10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes) Vibration resistance 10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes) Min. 98m/s2 (4 times on 3 axes) Shock resistance Min. 980m/s2 (5 times on 3 axes) Functional Destructive Functional Destructive Between live and dead metal parts Between input and output Between contacts of different poles Between contacts of same pole Insulation resistance (Initial value) 2,000Vrms for 1 min Between live and metal parts 2,000Vrms for 1 min Between input and output 2,000Vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole Breakdown voltage (Initial value) Setting error Voltage error Contact resistance (Initial value) Min. power off time 300ms Max. temperature rise 55..C 131..F Contact material Silver alloy Temperature error Contact arrangement Operation mode Approx. 10VA (100 to 240V AC) Approx. 2.5VA (24V AC) Approx. 1.5W (12V DC, 24V DC, 48 to 125V DC) Rated power consumption Rating Time accuracy Note:1) Contact Life Electrical function Mechanical function Operating condition Others Min. 100M.. (At 500V DC) Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C 68°F ambient temperature, and 1s power off time. 2) For the 1s range, the tolerance for each specification becomes ±10ms. 3) As internal components may become worn when using continuous conduction, the product should be replaced periodically. UL File No.: E122222 CSA File No.: LR39291 Analog Timers 09/2009

Open the catalog to page 1
PM4H-W - analog timer - twin - 2

51 PM4H-W Product types PM4H-W Twin timer Type Contact arrangement Time range Rated Operating Part number voltage Protective structure Terminal type Operating mode PM4HW-H-AC240VW PM4HW-H-AC240VSW PM4HW-H-DC125VW PM4HW-H-DC125VSW PM4HW-H-24VW PM4HW-H-24VSW PM4HW-H-DC12VW PM4HW-H-DC12VSW PM4HW-H-AC240V PM4HW-H-AC240VS PM4HW-H-DC125V PM4HW-H-DC125VS PM4HW-H-24V PM4HW-H-24VS PM4HW-H-DC12V PM4HW-H-DC12VS 8 pins Screw terminal 8 pins Screw terminal 8 pins Screw terminal 8 pins Screw terminal 8 pins Screw terminal 8 pins Screw terminal 8 pins Screw terminal 8 pins Screw terminal 100 to 240V AC 48...

Open the catalog to page 2
PM4H-W - analog timer - twin - 3

52 PM4H SERIES MODES AND TIME SETTING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. Turn the operation mode selector with screw driver. Operation mode is shown up through the window above the mode selector. The marks are , , , , , , , . Turn the mode selector to the mark until you can check by clicking sound. Confirm the mode selector position if it is correct. If the position is not stable, the timer might mis-operate. 2) Time range setting [PM4H series common] 16 time ranges are selectable between 1s to 500h....

Open the catalog to page 3
PM4H-W - analog timer - twin - 4

53 PRECAUTIONS IN USING THE PM4H SERIES 1. Input connections (PM4H-A type) 1) Be sure not to use terminal .. as the common terminal of the input signal as shown in Fig. A. Otherwise, the internal circuit of the timer may be damaged. Use terminal .. as the common terminal as shown in Fig. B. If the circuits is connected as in Fig. C, the internal circuits must be broken. Be sure to connect the circuit as in Fig. D. 2) When one input signal is simultaneously applied to more than one timer, be sure to avoid the wiring shown in Fig. E. Otherwise, the short-circuit current will flow and cause...

Open the catalog to page 4
PM4H-W - analog timer - twin - 5

54 PRECAUTIONS IN USING THE PM4H SERIES 5. Superimposed surge of power supply (PM4H series common) For the superimposed surge of power supply, the standard waveform is taken as the standard value for surge-proof voltage. If external surge occurs exceeding the specified value, the internal circuit may break down. In this case, use a surge absorption element. The positive and negative voltages are applied each five times between the power pins. The typical surge absorption elements include a varistor, a capacitor, and a diode. If a surge absorption element is used, use an oscilloscope to see...

Open the catalog to page 5

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages