Overview Eco-POWER METERs - 1

ECO-POWER METERS

Open the catalog to page 1
Overview Eco-POWER METERs - 2

Panasonic Eco-POWER METERS overview Visualizing energy consumption to save energy Install Eco-POWER METERS in lighting equipment, air conditioners, and production equipment to measure pow- er consumption and check the current status. Afterwards, with specific targets in place, the implementation and management of an energy savings plan is quick and simple. Visualizing target achievements improves the ener- gy usage cycle and allows for changes to be made to maximize efficiency. , of an energy saving plan i Energy saving target setting

Open the catalog to page 2
Overview Eco-POWER METERs - 3

Product overview

Open the catalog to page 3
Overview Eco-POWER METERs - 4

Performance of Eco-POWER METERS 1) Without terminal block 2) With terminal block 4) Use commercially available current transformers (CT) with secondary currents of 1A or 5A and primary currents of 4000A or less. 5) The Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing. 6) Free of charge. For KW Watcher, a Web Datalogger Unit (DLU) is required.

Open the catalog to page 4
Overview Eco-POWER METERs - 5

Product name Expandable Standard DIN rail MEWTOCOL Modbus 1) AKW2152G is a pulse input unit and AKW2182G is an analog input unit. They do not have a power measurement function. 2) Optional terminal socket is required. 4} For 440V systems, a commercial voltage transformer (secondary current rating: 110V) is required. 5) The Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing. 6) Free of charge. For KW Watcher, a Web Datalogger Unit (DLU) is required.

Open the catalog to page 5
Overview Eco-POWER METERs - 6

Eco-POWER METERS Selection Guide Recommended model ► Need to measure multiple points ► Need to measure micro-power such as standby power ► Need for electric power surveillance ► Need to measure import and export energy Capable of simultaneously measuring up to three circuits in a 1-phase, 2-wire system • Capable of displaying small currents of 1 mA • Bidirectional measurement of electric energy ► Need to measure power of commercial current transformer installed at facility Need to measure high current circuits 1 Capable of direct input from a commercial 1A/5A current transformer on the...

Open the catalog to page 6
Overview Eco-POWER METERs - 7

Recommended model ► Need to simply visualize data on Eco-POWER METER ► Need to use the Eco-POWER METER for ► Need to collect data on SD card •Main unit has built-in memory • Transfer of data to SD memory card allows visualization on PC screens. ► Need to measure 3-phase 4-wire systems •Direct measurement even of 3-phase, be done without voltage transformer. ► Need for waterproof device or use in nar- row-space power meter •IEC IP66 certified protective structure DIN type (22.5mm) ideal for installation in ► Need to monitor demand •Built-in demand function •Alarm outputs when demand target...

Open the catalog to page 7
Overview Eco-POWER METERs - 8

KW9M is a type of power meter, which can promote energy saving by visualizing power consumption. It can also be used to monitor electric power with high accuracy. • Large-screen LCD with backlight clearly displays values in four • High accuracy: instantaneous active power: 1%, class 1 • Display updating time: 0.1s • Panel-mount type capable of multi-circuit measurement • Simultaneous measurement of up to three circuits in a 1-phase, Capable of displaying small currents of 1 mA or above • Bidirectional measurement of electric energy of each circuit • Compatible with AC/DC power supply •...

Open the catalog to page 8
Overview Eco-POWER METERs - 9

Measurement input specifications i) Errors resulting from current transformers (CT) and voltage transformers (VT) are not considered. Application examples

Open the catalog to page 9
Overview Eco-POWER METERs - 10

The Panasonic KW1M Eco-POWER METER can be hooked up directly to industrial 400VAC networks. • Screw and DIN-rail installation possible • Integrated RS485 interface (Modbus RTU/MEWTOCOL) • Automatic logging of measurement data at numerous selectable intervals (can be saved on SD card) • Diverse alarm functions, e.g. when current consumption levels • Clock/calendar function • Suited for measuring 3-phase currents of up to 400V AC • Monitors and displays the most important electrical parameters Order guide

Open the catalog to page 10
Overview Eco-POWER METERs - 11

Main unit i) SD/SDHC 2GB or 4GB memory card by Panasonic Corporation recommended 2) To format SD memory cards, please download and use the formatting software available on the Panasonic website, http://panasonic.jp/support/global/cs/sd/download

Open the catalog to page 11
Overview Eco-POWER METERs - 12

ECO-POWER METER • Direct measurement of 400V power loads • Improved measurement function • Instantaneous electric power • Electric energy • Voltage and current measurement for each phase • Power factor • Simultaneous power and pulse measurement • Supports networking (up to 99 stations can be connected) • Built-in memory • Log data can be saved to memory of main unit • Built-in battery (for memory backup) • Protects log data and time measurements from power failures • Logging of all types of energy by month, day and hour • Manual electric energy measurement • Clock/calendar function • Direct...

Open the catalog to page 12
Overview Eco-POWER METERs - 14

Order guide Panasonic's KW2G Eco-POWER METER allows you to manage energy more efficiently than ever. You can easily add up to 7 expansion units to the KW2G Eco-POWER METER, allowing you to gather data for several circuits at once. Expansion units • Measure power produced and consumed • USB port for easy PC connection • Simultaneous measurement of power and pulse input tems, or 16 circuits for 1-phase, 2-wire systems • Main unit can display measured values for both itself and expansion units • Easy expansion: Eliminate excess wiring by using up to seven expansion units to add the required...

Open the catalog to page 14
Overview Eco-POWER METERs - 16

• Compatible with systems of up to 3-phase, 3-wire • Support for 400V AC power measurement (use with external voltage transformer) • KW4M: Also easy to mount on a panel surface with a mounting frame (sold separately) Supports networking (RS485 port) • KW4M: Protective structure: IEC IP66 (only front panel with rub- • DIN rail type (KW7M) ideal for installation in a panel Order guide For detailed information please refer to our website 1) The Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing.

Open the catalog to page 16

All Panasonic Electric Works Europe catalogs and technical brochures

  1. FM-200

    12 Pages

  2. FPWIN Pro

    8 Pages

  3. GX-F/H SERIES

    16 Pages

  4. IONIZER

    36 Pages

  5. AC Servo

    155 Pages

  6. Overview HMI

    36 Pages

  7. UJ30/35

    12 Pages

  8. Laser markers

    28 Pages

Archived catalogs

  1. MC-100EX/MS

    1 Pages

  2. Base 2324

    2 Pages

  3. Dicool

    24 Pages

  4. LT4H-W

    8 Pages

  5. P400 and P400S

    20 Pages

  6. A-Series

    6 Pages